← Back
Two family brick
110-26 62 DRIVE
QUEENS · BIN 4051952
💬 Discuss this project
1950Year Built
2Stories
B1Building Class
R4Zoning
1,540 sfGross Floor Area
2Units
0 Open Violations
Two family brick · 4,000 sf lot · 0.39 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Cellar3p · 1 filing · 20 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
PARIKH ARCHITECTURAL P.C.406/15/2025
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
AMAR CONSTRUCTION INCGeneral Contractor403/21/2026
CROWN PLUMBING INCPlumbing107/17/2026
FLINT MECHANICAL CORPPlumbing106/28/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
PARIKH ARCHITECTURAL P.C.1470406/15/2025
Building Lifecycle
All (69)Filed (4)Permit Issued (4)Signed Off (1)Violation (1)Inspection (7)Objection (42)Special Inspection (10)
07/16/2026
Permit issued — Plumbing
Q01126268-S1-PL
10/16/2025
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
10/15/2025
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
07/15/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
07/11/2025
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
07/03/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
BINA PARIKH
06/15/2025
Filed — Alteration
Internal work at Cellar. Relocate exist. toilet door, provide fire rated door and type "X" gyp boards and F. A. Intake to boiler room. No change in use, occupancy or egress.
Q01126268-P2
05/19/2025
Permit issued — Plumbing
Q01126268-S1-PL
04/29/2025
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
04/15/2025
Signed off — Alteration
Internal work at Cellar. Relocate exist. toilet door, provide fire rated door and type "X" gyp boards and F. A. Intake to boiler room. No change in use, occupancy or egress.
Q01126268-S5
04/10/2025
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
03/24/2025
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
03/14/2025
Permit issued — General Construction
Q01126268-S5-GC
02/16/2025
Objection resolved — Addressed
02/16/2025
Objection resolved — Addressed
02/16/2025
Objection resolved — Addressed
02/16/2025
Objection resolved — Addressed
02/16/2025
Special inspection requirement — Fire-Resistance Rated Construction
BINA PARIKH
02/13/2025
Objection raised — Cost
02/13/2025
Objection raised — Scope
02/13/2025
Objection raised — Fire_Protection
02/13/2025
Objection raised — Scope
02/03/2025
Filed — Alteration
Internal work at Cellar. Relocate exist. toilet door, provide fire rated door and type "X" gyp boards and F. A. Intake to boiler room. No change in use, occupancy or egress.
Q01126268-S5
02/02/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
BINA PARIKH
01/13/2025
Permit issued — General Construction
Q01126268-I1-GC-CX
12/06/2024
Objection resolved — Addressed
12/01/2024
Objection resolved — Addressed
12/01/2024
Objection resolved — Addressed
11/29/2024
Objection resolved — Addressed
11/28/2024
Objection resolved — Addressed
11/28/2024
Objection resolved — Addressed
11/28/2024
Objection resolved — Addressed
11/28/2024
Objection resolved — Addressed
11/28/2024
Objection resolved — Addressed
11/28/2024
Objection resolved — Addressed
11/28/2024
Objection resolved — Addressed
11/28/2024
Objection resolved — Addressed
11/28/2024
Special inspection requirement — Masonry
BINA PARIKH
11/28/2024
Special inspection requirement — Concrete - Cast-In-Place
BINA PARIKH
11/28/2024
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
BINA PARIKH
11/26/2024
Objection raised — Other
11/22/2024
Objection resolved — Addressed
11/22/2024
Objection resolved — Addressed
11/22/2024
Objection resolved — Addressed
11/22/2024
Objection resolved — Addressed
11/22/2024
Objection resolved — Addressed
11/18/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
BINA PARIKH
11/18/2024
Special inspection requirement — Fire-Resistance Rated Construction
BINA PARIKH
11/04/2024
Objection raised — Inspections
11/04/2024
Objection raised — Other
11/04/2024
Objection raised — Mechanical
11/04/2024
Objection raised — Other
11/04/2024
Objection raised — Fire_Protection
11/04/2024
Objection raised — Structural
11/04/2024
Objection raised — Fire_Protection
11/04/2024
Objection raised — Inspections
11/04/2024
Objection raised — Admin
11/04/2024
Objection raised — Scope
10/31/2024
Objection raised — Scope
10/31/2024
Objection raised — Other
Latest 60 of 69 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offCROWN PLUMBING INC07/16/2026
DOB NOWPlumbingSigned-offFLINT MECHANICAL CORP05/19/2025
DOB NOWGeneral ConstructionSigned-offAMAR CONSTRUCTION INC03/14/2025
DOB NOWGeneral ConstructionSigned-offAMAR CONSTRUCTION INC01/13/2025
1 project · most recent 06/15/2025
Others
FiledStatusContractorScopeMake / Model / Capacity
06/15/2025Signed-offAMAR CONSTRUCTION INCOthers
Other
Delta ITG50LED 50 CFM · Exhaust Fan ×1
1 project · most recent 06/15/2025
Gas Water/Sanitary
FiledStatusContractorScope
06/15/2025Signed-offCROWN PLUMBING INCGas, Water/Sanitary
▾Field Inspections (DOB CAP) — 7
DateTypeResultReport
10/16/2025Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
10/15/2025Pass-Final PL - Up to 3 Requested FloorsPassView ↗
07/15/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
07/11/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
04/29/2025Pass-Final General Construction Non-Directive 14PassView ↗
04/10/2025Pass-Final General Construction Non-Directive 14PassView ↗
03/24/2025Fail-Final General Construction Non-Directive 14FailView ↗
▾Special Inspection Requirements (DOB NOW) — 10
DateRequirementInspectorRole
07/03/2025Fire-Resistant Penetrations and JointsBINA PARIKHspecial
02/16/2025Fire-Resistance Rated ConstructionBINA PARIKHprogress
02/02/2025Fire-Resistant Penetrations and JointsBINA PARIKHspecial
11/28/2024MasonryBINA PARIKHspecial
11/28/2024Concrete - Cast-In-PlaceBINA PARIKHspecial
11/28/2024Excavations - Sheeting, Shoring, and BracingBINA PARIKHspecial
11/18/2024Fire-Resistant Penetrations and JointsBINA PARIKHspecial
11/18/2024Fire-Resistance Rated ConstructionBINA PARIKHprogress
10/12/2024Mechanical SystemsBINA PARIKHspecial
10/12/2024FinalBINA PARIKHprogress
▾Documents — 20 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/21/2026Q01126268-I1Request digital key ↗
08/21/2026Q01126268-S5Request digital key ↗
08/21/2026Q01126268-S1Request digital key ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications14
▸DOB NOWSpecial Inspector Seal & Signature7
09/25/2026Q01126268-I1Open ↗
09/25/2026Q01126268-I1Open ↗
09/25/2026Q01126268-I1Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/21/2026Q01126268-S1Open ↗
08/13/2026Q01126268-I1Open ↗
08/13/2026Q01126268-S5Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProgress Inspector Seal & Signature3
09/25/2026Q01126268-I1Open ↗
09/25/2026Q01126268-I1Open ↗
08/25/2026Q01126268-S5Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/13/2026Q01126268-I1Open ↗
08/13/2026Q01126268-S5Open ↗