← Back
General warehouse
58-97 57 STREET
QUEENS · BIN 4059030
💬 Discuss this project
1969Year Built
1Stories
E1Building Class
M1-1Zoning
30,000 sfGross Floor Area
1Units
LL97 Covered0 Open Violations
General warehouse · Owner of record: REN EMPIRE REALTY INC. · 33,000 sf lot · 0.91 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingGeneral
Roof5p · 3 filings · 6 docs
Floor 13p · 3 filings · 8 docs
Cellar2p · 2 filings · 4 docs
1 job · most recent 12/27/2022
Heating Systems
FiledStatusContractorScopeMake / Model / Capacity
12/27/2022——Heating Systems
Heating
Modine ×3
1 job · most recent 12/27/2022
Storm Water/Sanitary
FiledStatusContractorScope
12/27/2022——Storm, Water/Sanitary
1 job · most recent 11/26/2019
FiledStatusContractorScope
11/26/2019CompleteWILLDAN ELECTRICAL OF NY—
2 jobs · most recent 06/29/2022
Steel
FiledStatusContractorScope
06/29/2022——1 scope_items
06/10/2022——Steel
Building Lifecycle
All (56)Filed (8)Permit Issued (1)Violation (3)Objection (28)Special Inspection (16)
07/24/2025
Objection resolved — Addressed
07/24/2025
Objection resolved — Addressed
07/24/2025
Objection resolved — Addressed
07/24/2025
Objection resolved — Addressed
07/24/2025
Special inspection requirement — Maintenance information
07/15/2025
Objection raised — Plumbing
07/15/2025
Objection raised — Plumbing
07/15/2025
Objection raised — Fire_Protection
07/15/2025
Objection raised — Inspections
06/27/2025
Filed — Alteration
To file BE boiler work type. Install new boiler at the 1st floor. No change in use, egress or occupancy under this application.
Q01242330-I1
06/27/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
06/27/2025
Special inspection requirement — Heating Systems
06/27/2025
Special inspection requirement — HVAC-R and service water heating equipment
06/27/2025
Special inspection requirement — HVAC-R and service water heating system controls
06/27/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
01/25/2024
Permit issued — General Construction
Q00977891-I1-GC
01/11/2024
Filed — Alteration
PROPOSE FILE APPLICATION TO INSTALL NEW LOW CONCRETE WALL. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q00977891-I1
12/27/2022
Filed — Alteration
Proposed Plumbing Work for an Existing Warehouse.
Q00783994-I1
12/27/2022
Filed — Alteration
REMOVE AND CAP EXISTING GAS BOILER EQUIPMENT; AND INSTALL NEW GAS HEAT SPACE HEATERS (GAS FURNACES) PER PLAN. NO CHANGE IN USE, EGRESS, AND OCCUPANCY.
Q00784031-I1
08/03/2022
Filed — Alteration
Q00784497-I1
07/29/2022
Special inspection requirement — Final
07/29/2022
Special inspection requirement — Mechanical Systems
07/20/2022
Objection raised — Accessibility
07/20/2022
Objection resolved — Addressed
07/07/2022
Objection raised — Admin
07/07/2022
Objection resolved — Addressed
07/07/2022
Objection raised — Structural
07/07/2022
Objection resolved — Addressed
07/07/2022
Objection raised — Admin
07/07/2022
Objection resolved — Addressed
07/07/2022
Objection raised — Structural
07/07/2022
Objection resolved — Addressed
07/07/2022
Objection raised — Inspections
07/07/2022
Objection resolved — Addressed
07/07/2022
Objection raised — Admin
07/07/2022
Objection resolved — Addressed
07/07/2022
Objection raised — Admin
07/07/2022
Objection resolved — Addressed
06/29/2022
Filed — Alteration
FILING FOUNDATION WORK IN CONJUNCTION WITH ALT 1 JOB#Q00686953I1
Q00752227-I1
06/13/2022
Objection raised — Accessibility
06/13/2022
Objection resolved — Addressed
06/12/2022
Special inspection requirement — Protection of exposed foundation insulation
06/12/2022
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
06/12/2022
Special inspection requirement — Insulation placement and R values
06/10/2022
Filed — Alteration
filing structural work type in conjunction with ALT1 job#Q00686953I1
Q00752234-I1
06/09/2022
Special inspection requirement — Structural Stability – Alterations of existing buildings
06/09/2022
Special inspection requirement — Concrete - Cast-In-Place
06/09/2022
Special inspection requirement — Subgrade Inspections
06/06/2022
Special inspection requirement — Footing and Foundation
06/06/2022
Special inspection requirement — Final
03/15/2022
Objection raised — Scope
03/15/2022
Objection resolved — Addressed
03/07/2022
Filed — Alteration CO
PROPOSED INTERIOR RENOVATION AND INCREASED THE BUILDING HEIGHT TO AN EXISTING 1-STORY WAREHOUSE
Q00689600-I1
11/02/2019
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
08/02/2019
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/02/2019
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
SD DESIGN STUDIO LLC503/22/2026
REN EMPIRE REALTY INC.103/22/2026
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
SD DESIGN STUDIO203/21/2026
JRK CREATIVE203/21/2026
CHANG HWA TAN203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
JRL SKYLINE INCGeneral Contractor203/21/2026
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedJRL SKYLINE01/25/2024
BISMHISSUEDBROAD TRADE PLUMBING & HE10/26/2010
BIS—ISSUEDDEPENDABLE SCRAP CO.12/17/1990
▾Special Inspection Requirements (DOB NOW) — 16
DateRequirementInspectorRole
07/24/2025Maintenance information—energy_progress
06/27/2025Fire-Resistant Penetrations and Joints—special
06/27/2025Heating Systems—special
06/27/2025HVAC-R and service water heating equipment—energy_progress
06/27/2025HVAC-R and service water heating system controls—energy_progress
06/27/2025HVAC-R and service water piping design and insulation—energy_progress
07/29/2022Final—progress
07/29/2022Mechanical Systems—special
06/12/2022Protection of exposed foundation insulation—energy_progress
06/12/2022Excavations - Sheeting, Shoring, and Bracing—special
06/12/2022Insulation placement and R values—energy_progress
06/09/2022Structural Stability – Alterations of existing buildings—special
06/09/2022Concrete - Cast-In-Place—special
06/09/2022Subgrade Inspections—special
06/06/2022Footing and Foundation—progress
06/06/2022Final—progress
▾Documents — 33 on file (BIS + DOB NOW)
▸Plans & Drawings7
▸DOB NOWPlans/Sketch7
08/26/2026Q00784497-I1Request digital key ↗
08/25/2026Q00783994-I1Request digital key ↗
08/25/2026Q00784031-I1Request digital key ↗
Showing 3 of 7 on file for this type
▸Applications & Permits2
▸BISPLAN / WORK APPROVAL APPLICATION1
10/19/2010420276249Open ↗
▸BISWORK PERMIT APPLICATION1
10/27/2010420276249Open ↗
▸Seals & Professional Certifications9
▸DOB NOWDPL-1: Design Professional Seal & Signature7
08/26/2026Q00752227-I1Open ↗
08/26/2026Q00784497-I1Open ↗
08/19/2026Q01242330-I1Open ↗
Showing 3 of 7 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION2
11/22/2011420276249Open ↗
10/19/2010420276249Open ↗
▸Trade Schedules & Equipment5
▸BISEQUIPMENT USE PERMITS3
11/22/2011420276249Open ↗
11/22/2011420276249Open ↗
11/22/2011420276249Open ↗
▸BISEQUIPMENT USE APPLICATION/PERMIT2
11/22/2011420276249Open ↗
10/19/2010420276249Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/19/2026Q01242330-I1Open ↗
08/13/2026Q00977891-I1Open ↗
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'1
10/19/2010420276249Open ↗
▸Energy Compliance1
▸BISTECHNICAL REPORT: ENERGY1
11/22/2011420276249Open ↗
▸Approvals, Objections & Sign-offs3
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
11/22/2011420276249Open ↗
▸BISADMINISTRATIVE OBJECTIONS1
10/19/2010420276249Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION1
11/22/2011420276249Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
11/22/2011420276249Open ↗
10/19/2010420276249Open ↗
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1
10/19/2010420276249Open ↗