← Back
Miscellaneous one family
59-21 54 STREET
QUEENS · BIN 4059065
💬 Discuss this project
1920Year Built
1Stories
A9Building Class
M1-1Zoning
900 sfGross Floor Area
1Units
Miscellaneous one family · 2,500 sf lot · 0.36 FAR built · Flood zone X
Locations of Work
ArchitectureMechanical
Roof2p · 1 filing · 10 docs
Floor 21p · 2 filings · 20 docs
Floor 12p · 2 filings · 20 docs
Cellar2p · 2 filings · 20 docs
Basement1p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
AR CONSTRUCTION MGMT1203/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NEW AGE ENGINEERING PLLC204/23/2025
NORMAN C. LOK, PE404/17/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
W J PROFESSIONAL EXPEDITING COMPANY1203/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NEW AGE ENGINEERING PLLC7746104/23/2025
Building Lifecycle
All (70)Filed (6)Objection (36)Special Inspection (28)
07/22/2025
Objection resolved — Addressed
06/25/2025
Objection raised — Energy
06/24/2025
Objection resolved — Addressed
06/24/2025
Objection resolved — Addressed
06/17/2025
Objection resolved — Addressed
06/17/2025
Objection resolved — Addressed
06/17/2025
Objection resolved — Addressed
06/17/2025
Objection resolved — Addressed
06/17/2025
Objection resolved — Addressed
06/17/2025
Objection resolved — Addressed
06/03/2025
Objection resolved — Addressed
06/03/2025
Objection resolved — Addressed
06/03/2025
Objection resolved — Addressed
05/28/2025
Objection raised — Energy
05/28/2025
Objection raised — Cost
05/21/2025
Objection raised — Zoning
05/21/2025
Objection raised — Zoning
05/21/2025
Objection raised — Admin
05/21/2025
Objection raised — Fire_Protection
05/21/2025
Objection raised — Structural
05/21/2025
Objection raised — Zoning
05/21/2025
Objection raised — Admin
05/16/2025
Objection raised — Energy
05/13/2025
Objection resolved — Addressed
05/13/2025
Objection resolved — Addressed
05/07/2025
Objection raised — Other
05/06/2025
Objection resolved — Addressed
05/06/2025
Objection resolved — Addressed
05/06/2025
Objection resolved — Addressed
05/06/2025
Special inspection requirement — Duct leakage testing, insulation and design
Stephen Shishko
05/05/2025
Objection raised — Admin
05/05/2025
Objection raised — Cost
05/01/2025
Objection raised — Structural
05/01/2025
Objection raised — Admin
05/01/2025
Objection raised — Admin
05/01/2025
Objection resolved — Addressed
05/01/2025
Objection raised — Admin
04/23/2025
Filed — Alteration CO
SUBS.EQUENT FILING FOR MECHANICAL WORK FOR CELLAR AND FIRST FLOOR AND PROPOSED 2ND FLOOR VERTICAL ENLARGEMENT AS PER PLANS FILED HEREWITH.
Q01211306-S2
04/17/2025
Filed — Alteration CO
SUBS.EQUENT FILING FOR MECHANICAL WORK FOR CELLAR AND FIRST FLOOR AND PROPOSED 2ND FLOOR VERTICAL ENLARGEMENT AS PER PLANS FILED HEREWITH.
Q01211306-S1
04/17/2025
Filed — Alteration CO
SUBS.EQUENT FILING FOR MECHANICAL WORK FOR CELLAR AND FIRST FLOOR AND PROPOSED 2ND FLOOR VERTICAL ENLARGEMENT AS PER PLANS FILED HEREWITH.
Q01211306-I1
04/17/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
Stephen Shishko
04/16/2025
Special inspection requirement — HVAC-R and service water heating equipment
Stephen Shishko
04/16/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
Stephen Shishko
04/16/2025
Special inspection requirement — HVAC-R and service water heating system controls
Stephen Shishko
04/16/2025
Special inspection requirement — Mechanical Systems
Stephen Shishko
04/16/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Stephen Shishko
04/16/2025
Special inspection requirement — Final
Stephen Shishko
04/16/2025
Special inspection requirement — Energy Code Compliance Inspections
Stephen Shishko
04/16/2025
Special inspection requirement — Maintenance information
Stephen Shishko
02/10/2025
Filed — Alteration
FILING FOR INTERIOR RENOVATION OF CELLAR AND FIRST FLOOR AND PROPOSED 2ND FLOOR ADDITION VERTICAL ENLARGEMENT AS PER PLANS FILED HEREWITH. NO CHANGE IN EGRESS, USE OR OCCUPANCY
Q01169252-S2
02/10/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
02/10/2025
Special inspection requirement — Maintenance information
02/10/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
02/07/2025
Filed — Alteration
FILING FOR INTERIOR RENOVATION OF CELLAR AND FIRST FLOOR AND PROPOSED 2ND FLOOR ADDITION VERTICAL ENLARGEMENT AS PER PLANS FILED HEREWITH. NO CHANGE IN EGRESS, USE OR OCCUPANCY
Q01169252-S1
02/06/2025
Filed — Alteration
FILING FOR INTERIOR RENOVATION OF CELLAR AND FIRST FLOOR AND PROPOSED 2ND FLOOR ADDITION VERTICAL ENLARGEMENT AS PER PLANS FILED HEREWITH. NO CHANGE IN EGRESS, USE OR OCCUPANCY
Q01169252-I1
02/06/2025
Special inspection requirement — Metering
02/06/2025
Special inspection requirement — Interior lighting power
02/06/2025
Special inspection requirement — Fenestration areas
02/06/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
02/06/2025
Special inspection requirement — Energy Code Compliance Inspections
Latest 60 of 70 events.
Nothing on file for this building.
2 jobs · most recent 04/23/2025
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
04/23/2025——Heating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Mitsubishi Electric SUZ-KA30NAHZ 32,000 BTU · Condensing Unit ×2
SVZ-KP30NA 32,000 BTU · Fan Coil Indoor ×2
SLZ-KF18NA 18,800 BTU · Vrf Indoor ×1
SUZ-KA18NAHZ 18,800 BTU · Condensing Unit ×1
SUZ-KP18NA 22,540 BTU · Condensing Unit ×1
SVZ-KP18NA 22,540 BTU · Fan Coil Indoor ×1
Ventilation
Panasonic F-0511VKL2 50 CFM · Exhaust Fan ×4
F-08-11VF5 104 CFM · Kitchen Exhaust ×1
02/10/2025——Heating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Mitsubishi Electric SUZ-KA30NAHZ 32,000 BTU · Condensing Unit ×2
SVZ-KP30NA 32,000 BTU · Fan Coil Indoor ×2
SLZ-KF18NA 18,800 BTU · Vrf Indoor ×1
SUZ-KA18NAHZ 18,800 BTU · Condensing Unit ×1
SUZ-KP18NA 22,540 BTU · Condensing Unit ×1
SVZ-KP18NA 22,540 BTU · Fan Coil Indoor ×1
Ventilation
Panasonic F-0511VKL2 50 CFM · Exhaust Fan ×4
F-08-11VF5 104 CFM · Kitchen Exhaust ×1
2 jobs · most recent 04/23/2025
Gas Water/Sanitary
FiledStatusContractorScope
04/23/2025——Gas, Water/Sanitary
02/10/2025——Gas, Water/Sanitary
1 job · most recent 04/23/2025
Concrete
FiledStatusContractorScope
04/23/2025——Concrete
▾Special Inspection Requirements (DOB NOW) — 28
DateRequirementInspectorRole
05/06/2025Duct leakage testing, insulation and designStephen Shishkoenergy_progress
04/17/2025Structural Stability – Alterations of existing buildingsStephen Shishkospecial
04/16/2025HVAC-R and service water heating equipmentStephen Shishkoenergy_progress
04/16/2025HVAC-R and service water piping design and insulationStephen Shishkoenergy_progress
04/16/2025HVAC-R and service water heating system controlsStephen Shishkoenergy_progress
04/16/2025Mechanical SystemsStephen Shishkospecial
04/16/2025Fire-Resistant Penetrations and JointsStephen Shishkospecial
04/16/2025FinalStephen Shishkoprogress
04/16/2025Energy Code Compliance InspectionsStephen Shishkoprogress
04/16/2025Maintenance informationStephen Shishkoenergy_progress
02/10/2025Fire-Resistant Penetrations and Joints—special
02/10/2025Maintenance information—energy_progress
02/10/2025HVAC-R and service water piping design and insulation—energy_progress
02/06/2025Metering—energy_progress
02/06/2025Interior lighting power—energy_progress
02/06/2025Fenestration areas—energy_progress
02/06/2025Fire-Resistant Penetrations and Joints—special
02/06/2025Energy Code Compliance Inspections—progress
02/06/2025Fire-Resistance Rated Construction—progress
02/06/2025Fireplaces—energy_progress
02/06/2025Air barrier - visual inspection—energy_progress
02/06/2025Fenestration and door U-factor and product ratings—energy_progress
02/06/2025Permanent certificate—energy_progress
02/06/2025Fenestration air leakage—energy_progress
02/06/2025Insulation placement and R values—energy_progress
Latest 25 of 28.
▾Documents — 25 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch6
08/21/2026Q01169252-S2Request digital key ↗
08/21/2026Q01169252-S1Request digital key ↗
08/21/2026Q01169252-I1Request digital key ↗
Showing 3 of 6 on file for this type
▸Zoning, Tax Lot & Property Records2
▸DOB NOWZD1: DOB Zoning Diagram2
08/13/2026Q01211306-I1Open ↗
08/13/2026Q01169252-I1Open ↗
▸Seals & Professional Certifications10
▸DOB NOWDPL-1: Design Professional Seal & Signature6
08/20/2026Q01211306-S1Open ↗
08/20/2026Q01211306-I1Open ↗
08/20/2026Q01211306-S2Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWProgress Inspector Seal & Signature3
08/26/2026Q01211306-S2Open ↗
08/26/2026Q01211306-S2Open ↗
08/26/2026Q01211306-S2Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/26/2026Q01211306-S2Open ↗
▸Other Documents7
▸DOB NOWSite Survey: Initial2
08/13/2026Q01211306-I1Open ↗
08/13/2026Q01169252-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone2
08/13/2026Q01169252-I1Open ↗
08/13/2026Q01211306-I1Open ↗
▸DOB NOWPlot Diagram2
08/13/2026Q01169252-I1Open ↗
08/13/2026Q01211306-I1Open ↗
▸DOB NOWProperty Ownership Certification1
08/20/2026Q01211306-I1Open ↗