| Owner | Filings | Most Recent |
|---|---|---|
| SFE ENGINEERING | 16 | 09/13/2026 |
| JESM DEVELOPMENT LLC | 1 | 03/22/2026 |
| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 07/16/2025 | $1.4M | — | Private party → JESM DEVELOPMENT LLC | $625/sf building |
| Firm | Filings | Most Recent |
|---|---|---|
| BAYSIDE ENGINEERING PC | 11 | 08/14/2026 |
| Representative | Filings | Most Recent |
|---|---|---|
| CNY ENGINEERING PC | 4 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| L&L CONSTRUCTION DEVELOP | General Contractor | 6 | 08/25/2026 |
| LXC CONSTRUCTION INC | General Contractor | 1 | 06/28/2026 |
| CATMAN PLUMBING INC | Plumbing | 1 | 09/02/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| SD TESTING & INSPECTION S | 7010 | 5 | 06/24/2026 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Plumbing | Permit Issued | CATMAN PLUMBING INC | 09/01/2026 |
| DOB NOW | General Construction | Permit Issued | L&L CONSTRUCTION DEVELOP | 08/24/2026 |
| DOB NOW | Foundation | Permit Issued | L&L CONSTRUCTION DEVELOP | 08/21/2026 |
| DOB NOW | Construction Fence | Permit Issued | L&L CONSTRUCTION DEVELOP | 08/21/2026 |
| DOB NOW | Foundation | Permit Issued | L&L CONSTRUCTION DEVELOP | 08/21/2026 |
| DOB NOW | General Construction | Permit Issued | L&L CONSTRUCTION DEVELOP | 08/21/2026 |
| DOB NOW | Support of Excavation | Permit Issued | L&L CONSTRUCTION DEVELOP | 08/20/2026 |
| DOB NOW | Construction Fence | Signed-off | LXC CONSTRUCTION INC | 06/26/2026 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 06/24/2026 | Permit Issued | L&L CONSTRUCTION DEVELOP | Heating and Air Conditioning Systems, Ventilation Systems | Heat / Cool Mitsubishi Electric MXZ-3C24NA3 22,000 BTU · Condensing Unit ×9 PUHY-P120TNU-A 120,000 BTU · Vrf Outdoor ×2 PUHY-P96TNU-A 96,000 BTU · Vrf Outdoor ×2 MXZ-3C30NA3 28,400 BTU · Condensing Unit ×1 Ventilation Greenheck G-070-VG 244 CFM · Exhaust Fan ×4 |
| 08/12/2025 | — | — | Heating and Air Conditioning Systems, Ventilation Systems | Heat / Cool Mitsubishi Electric MXZ-3C24NA3 22,000 BTU · Condensing Unit ×9 PUHY-P120TNU-A 120,000 BTU · Vrf Outdoor ×2 PUMY-P60NKMU 60,000 BTU · Vrf Outdoor ×2 MXZ-3C30NA3 28,400 BTU · Condensing Unit ×1 Ventilation Greenheck G-070-VG 244 CFM · Exhaust Fan ×4 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 06/24/2026 | — | — | Sprinkler System |
| 08/12/2025 | — | — | Sprinkler System |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 06/24/2026 | Permit Issued | CATMAN PLUMBING INC | Storm, Water/Sanitary |
| 08/12/2025 | — | — | Storm, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 06/24/2026 | Permit Issued | CATMAN PLUMBING INC | 1 scope_items |
| 08/12/2025 | — | — | 1 scope_items |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 08/14/2026 | Permit Issued | L&L CONSTRUCTION DEVELOP | Fence |
| 04/16/2026 | Signed-off | LXC CONSTRUCTION INC | Fence |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 07/16/2026 | Vestibules | XIUCHENG LI | energy_progress |
| 07/16/2026 | Protection of exposed foundation insulation | XIUCHENG LI | energy_progress |
| 07/16/2026 | Air barrier — testing | XIUCHENG LI | energy_progress |
| 06/10/2026 | Electrical motors and elevators | — | energy_progress |
| 06/10/2026 | Air barrier — testing | — | energy_progress |
| 06/10/2026 | Fenestration and door U-factor and product ratings | — | energy_progress |
| 06/10/2026 | Fire-Resistance Rated Construction | — | progress |
| 06/10/2026 | Energy Code Compliance Inspections | — | progress |
| 06/10/2026 | Subgrade Inspections | — | special |
| 06/10/2026 | Structural Stability – Alterations of existing buildings | — | special |
| 06/10/2026 | Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation | — | special |
| 06/10/2026 | Fire-Resistant Penetrations and Joints | — | special |
| 06/10/2026 | Exterior Insulation and Finish Systems (EIFS) | — | special |
| 06/10/2026 | Concrete - Cast-In-Place | — | special |
| 06/10/2026 | Maintenance information | — | energy_progress |
| 06/10/2026 | Fenestration air leakage | — | energy_progress |
| 06/10/2026 | Exterior lighting power | — | energy_progress |
| 06/10/2026 | Lighting controls | — | energy_progress |
| 06/10/2026 | Insulation placement and R values | — | energy_progress |
| 06/10/2026 | Metering | — | energy_progress |
| 06/10/2026 | Lighting in dwelling units | — | energy_progress |
| 06/10/2026 | Air barrier continuity plan testing | — | energy_progress |
| 06/10/2026 | Protection of exposed foundation insulation | — | energy_progress |
| 06/10/2026 | Fenestration areas | — | energy_progress |
| 06/10/2026 | Air barrier - visual inspection | — | energy_progress |