← Back
Three families
59-70 68 STREET
QUEENS · BIN 4062324
💬 Discuss this project
1955Year Built
3Stories
C0Building Class
R4-1Zoning
3,974 sfGross Floor Area
3Units
Three families · 4,040 sf lot · 0.98 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingGeneral
Permit Issued — active, not yet Signed-off
Roof4p · 1 filing · 10 docs
Floor 3Under Construction11p · 3 filings · 20 docs
Floor 2Under Construction8p · 2 filings · 20 docs
Floor 1Under Construction4p · 4 filings · 20 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NY BUILDING ASSOCIATES INC207/15/2025
JOHN P. FOX, ARCHITECT, PC.509/25/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
BROOKLYN SOLARWORKS203/21/2026
Cornerstone Consulting Services403/21/2026
CORNERSTONE CONSULTING103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
CRF CONSTRUCTION INCGeneral Contractor603/21/2026
BROOKLYN SOLARWORKS LLCGeneral Contractor203/21/2026
SIGNORE & SONS PLBG CORPPlumbing108/20/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NKM ENGINEERING PLLC6244207/15/2025
C.M. TESTING LABORATORY,1352107/26/2024
O'ROURKE ENGINEERING, LLC5873107/26/2024
Building Lifecycle
All (50)Filed (7)Permit Issued (4)Signed Off (1)Inspection (3)Objection (5)Special Inspection (30)
08/04/2026
Permit issued — Plumbing
Q01073253-I1-PL
07/16/2025
Signed off — Alteration
INSTALL SOLAR PV SYSTEM ON THE EXISTING ROOFTOP. NO CHANGES TO USE, EGRESS OR OCCUPANCY.
Q01165669-I1
07/15/2025
Filed — Alteration
INSTALL SOLAR PV SYSTEM ON THE EXISTING ROOFTOP. NO CHANGES TO USE, EGRESS OR OCCUPANCY.
Q01165669-P1
07/15/2025
Special inspection requirement — Air barrier - visual inspection
NARESH MAHANGU
07/15/2025
Special inspection requirement — Final
NARESH MAHANGU
07/15/2025
Special inspection requirement — Energy Code Compliance Inspections
NARESH MAHANGU
07/15/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
NARESH MAHANGU
07/15/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
NARESH MAHANGU
01/15/2025
Filed — Alteration
INSTALL SOLAR PV SYSTEM ON THE EXISTING ROOFTOP. NO CHANGES TO USE, EGRESS OR OCCUPANCY.
Q01165669-I1
01/15/2025
Permit issued — Solar
Q01165669-I1-SL
11/29/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
10/01/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
10/01/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
09/26/2024
Permit issued — Construction Fence
Q01116667-I1-FN
09/25/2024
Filed — Alteration
Q01116667-I1
09/25/2024
Permit issued — Mechanical Systems
Q01073241-I1-GC-CX
08/15/2024
Objection raised — Inspections
08/15/2024
Objection raised — Admin
08/15/2024
Objection raised — Zoning
08/15/2024
Objection raised — Zoning
08/15/2024
Objection raised — Structural
07/31/2024
Special inspection requirement — Permanent certificate
BRIAN O'ROURKE
07/31/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
BRIAN O'ROURKE
07/31/2024
Special inspection requirement — Air barrier - visual inspection
BRIAN O'ROURKE
07/31/2024
Special inspection requirement — Interior lighting power
BRIAN O'ROURKE
07/31/2024
Special inspection requirement — HVAC-R and service water heating system controls
BRIAN O'ROURKE
07/31/2024
Special inspection requirement — Insulation placement and R values
BRIAN O'ROURKE
07/31/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
JOHN SEMIOLI
07/31/2024
Special inspection requirement — HVAC-R and service water heating equipment
BRIAN O'ROURKE
07/31/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
BRIAN O'ROURKE
07/31/2024
Special inspection requirement — Masonry
JOHN SEMIOLI
07/31/2024
Special inspection requirement — Structural Steel - Details
JOHN SEMIOLI
07/31/2024
Special inspection requirement — Mechanical Systems
BRIAN O'ROURKE
07/31/2024
Special inspection requirement — Construction Utilizing CLT or SCL, Type IV
JOHN SEMIOLI
07/31/2024
Special inspection requirement — Final
BRIAN O'ROURKE
07/31/2024
Special inspection requirement — Energy Code Compliance Inspections
BRIAN O'ROURKE
07/31/2024
Special inspection requirement — Fenestration areas
BRIAN O'ROURKE
07/31/2024
Special inspection requirement — Fenestration and door U-factor and product ratings
BRIAN O'ROURKE
07/30/2024
Filed — Alteration
HEREBY FILING FOR AN EXISTING 2 FAMILY RESIDENCE INCLUDING INTERIOR REMOVAL AND RENOVATION, ENLARGE WINDOW OPENINGS AND INSTALL STRUCTURAL SUPPORT AS NOTED ON PLANS AND WORK AT EXTERIOR, WITH NEW SPLIT SYSTEMS AS PER PLANS
Q01073241-P1
07/30/2024
Filed — Alteration CO
HEREBY FILING COVERSION OF EXISTING TWO FAMILY RESIDENCE TO ONE FAMILY RESIDENCE. EXTERIOR WORK TO INCLUDE MODIFICATION OF SIDE YARD STEPS, INSTALL KNEE WALLS, REMOVE FRONT YARD CONCRETE, INSTALL NEW PAVERS AT WALKWAY AND CONCRETE AT DRIVEWAY.
Q01073270-I1
07/30/2024
Special inspection requirement — HVAC-R and service water heating equipment
07/30/2024
Special inspection requirement — Construction Utilizing CLT or SCL, Type IV
07/30/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
07/30/2024
Special inspection requirement — Masonry
07/30/2024
Special inspection requirement — Mechanical Systems
07/30/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
07/30/2024
Special inspection requirement — Structural Steel - Details
07/30/2024
Special inspection requirement — Energy Code Compliance Inspections
07/26/2024
Filed — Alteration
HEREBY FILING PLUMBING WORK AT FLOORS 1-3 AS PER PLANS., WORK TO INCLUDE REMOVAL OF ONE BOILER.
Q01073253-I1
07/26/2024
Filed — Alteration
HEREBY FILING FOR AN EXISTING 2 FAMILY RESIDENCE INCLUDING INTERIOR REMOVAL AND RENOVATION, ENLARGE WINDOW OPENINGS AND INSTALL STRUCTURAL SUPPORT AS NOTED ON PLANS AND WORK AT EXTERIOR, WITH NEW SPLIT SYSTEMS AS PER PLANS
Q01073241-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedSIGNORE & SONS PLBG CORP08/04/2026
DOB NOWSolarSigned-offBROOKLYN SOLARWORKS LLC01/15/2025
DOB NOWConstruction FencePermit IssuedCRF CONSTRUCTION INC09/26/2024
DOB NOWMechanical SystemsPermit IssuedCRF CONSTRUCTION INC09/25/2024
1 project · most recent 07/30/2024
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
07/30/2024Permit IssuedCRF CONSTRUCTION INCHeating and Air Conditioning Systems
Heat / Cool
Mitsubishi Electric MITSUBISHI - PMFY-P12NBMU-ER6 12,000 BTU · Vrf Indoor ×12
MITSUBISHI - PUMY-HP36NKMU1 36,000 BTU · Vrf Outdoor ×6
MITSUBISHI - MSZ-GL12NA 12,000 BTU · Ahu ×2
1 project · most recent 07/26/2024
Gas Water/Sanitary
FiledStatusContractorScope
07/26/2024Permit IssuedSIGNORE & SONS PLBG CORPGas, Water/Sanitary
2 projects · most recent 03/27/2025
General Wiring
FiledStatusContractorScope
03/27/2025CompleteBROOKYLN SOLARWORKS, LLC—
10/02/2024CompleteEFCO ELECTRICAL SERVI INCGeneral Wiring
1 project · most recent 07/30/2024
Steel Concrete Masonry Wood
FiledStatusContractorScope
07/30/2024Permit IssuedCRF CONSTRUCTION INCSteel, Concrete, Masonry, Wood
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
11/29/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
10/01/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
10/01/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 44
DateRequirementInspectorRole
07/15/2025Air barrier - visual inspectionNARESH MAHANGUenergy_progress
07/15/2025FinalNARESH MAHANGUprogress
07/15/2025Energy Code Compliance InspectionsNARESH MAHANGUprogress
07/15/2025Structural Stability – Alterations of existing buildingsNARESH MAHANGUspecial
07/15/2025Fire-Resistant Penetrations and JointsNARESH MAHANGUspecial
07/31/2024Permanent certificateBRIAN O'ROURKEenergy_progress
07/31/2024HVAC-R and service water piping design and insulationBRIAN O'ROURKEenergy_progress
07/31/2024Air barrier - visual inspectionBRIAN O'ROURKEenergy_progress
07/31/2024Interior lighting powerBRIAN O'ROURKEenergy_progress
07/31/2024HVAC-R and service water heating system controlsBRIAN O'ROURKEenergy_progress
07/31/2024Insulation placement and R valuesBRIAN O'ROURKEenergy_progress
07/31/2024Structural Stability – Alterations of existing buildingsJOHN SEMIOLIspecial
07/31/2024HVAC-R and service water heating equipmentBRIAN O'ROURKEenergy_progress
07/31/2024Fire-Resistant Penetrations and JointsBRIAN O'ROURKEspecial
07/31/2024MasonryJOHN SEMIOLIspecial
07/31/2024Structural Steel - DetailsJOHN SEMIOLIspecial
07/31/2024Mechanical SystemsBRIAN O'ROURKEspecial
07/31/2024Construction Utilizing CLT or SCL, Type IVJOHN SEMIOLIspecial
07/31/2024FinalBRIAN O'ROURKEprogress
07/31/2024Energy Code Compliance InspectionsBRIAN O'ROURKEprogress
07/31/2024Fenestration areasBRIAN O'ROURKEenergy_progress
07/31/2024Fenestration and door U-factor and product ratingsBRIAN O'ROURKEenergy_progress
07/30/2024HVAC-R and service water heating equipment—energy_progress
07/30/2024Construction Utilizing CLT or SCL, Type IV—special
07/30/2024Fire-Resistant Penetrations and Joints—special
Latest 25 of 44.
▾Documents — 49 on file (BIS + DOB NOW)
▸Plans & Drawings8
▸DOB NOWPlans/Sketch8
08/21/2026Q01073253-I1Request digital key ↗
08/21/2026Q01073241-P2Request digital key ↗
08/21/2026Q01073241-P1Request digital key ↗
Showing 3 of 8 on file for this type
▸Seals & Professional Certifications32
▸DOB NOWProgress Inspector Seal & Signature17
09/21/2026Q01165669-P1Open ↗
09/21/2026Q01165669-P1Open ↗
09/01/2026Q01073241-I1Open ↗
Showing 3 of 17 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature8
08/21/2026Q01073270-I1Open ↗
08/21/2026Q01073241-P1Open ↗
08/21/2026Q01073241-I1Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature7
09/21/2026Q01165669-P1Open ↗
09/01/2026Q01073241-I1Open ↗
09/01/2026Q01073241-I1Open ↗
Showing 3 of 7 on file for this type
▸Safety & Tenant Protection1
▸DOB NOWStreet Tree Checklist1
08/13/2026Q01073270-I1Open ↗
▸Environmental & Asbestos6
▸DOB NOWDEP ACP-5: Asbestos Assessment Report6
08/21/2026Q01073241-I1Open ↗
08/21/2026Q01073241-P1Open ↗
08/21/2026Q01165669-I1Open ↗
Showing 3 of 6 on file for this type
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026Q01165669-I1Open ↗
▸Other Documents1
▸DOB NOWProperty Ownership Certification1
08/15/2026Q01073270-I1Open ↗