← Back
One story - permanent living quarter
82-13 58 AVENUE
QUEENS · BIN 4066311
💬 Discuss this project
1930Year Built
1Stories
A2Building Class
R4-1Zoning
840 sfGross Floor Area
1Units
One story - permanent living quarter · 3,000 sf lot · 0.28 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Roof1p · 1 filing · 4 docs
Cellar1 filing · 4 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
10/26/2018$680K—Private party → Private party$810/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
S M TAM ARCHITECT, PLLC212/12/2022
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
HENRYSMITH PROPERTY MGMTGeneral Contractor203/21/2026
CONTROL PLBG & HTG INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
GLOBAL ARCH DESIGN & BUIL3397112/12/2022
Building Lifecycle
All (27)Filed (2)Permit Issued (2)Signed Off (1)Inspection (3)Objection (16)Special Inspection (3)
05/25/2023
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
05/25/2023
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
05/18/2023
Signed off — Alteration
MINOR NON-STRUCTURAL DEMOLITION AND PROPOSED MINOR PARTITION WORK AT THE CELLAR AS PER PLAN. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q08018515-I1
04/28/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
01/20/2023
Permit issued — Plumbing
Q08052203-I1-PL
12/28/2022
Objection resolved — Addressed
12/28/2022
Objection resolved — Addressed
12/21/2022
Objection resolved — Addressed
12/17/2022
Objection raised — Plumbing
12/17/2022
Objection raised — Admin
12/17/2022
Objection resolved — Addressed
12/17/2022
Objection raised — Scope
12/17/2022
Objection raised — Scope
12/17/2022
Objection resolved — Addressed
12/17/2022
Objection raised — Admin
12/17/2022
Objection resolved — Addressed
12/17/2022
Objection raised — Plumbing
12/12/2022
Filed — Alteration
Q08052203-I1
12/08/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
NITHIN JOHN
12/07/2022
Permit issued — General Construction
Q08018515-I1-GC
10/20/2022
Objection raised — Other
10/20/2022
Objection resolved — Addressed
10/20/2022
Objection raised — Scope
10/20/2022
Objection resolved — Addressed
10/14/2022
Filed — Alteration
MINOR NON-STRUCTURAL DEMOLITION AND PROPOSED MINOR PARTITION WORK AT THE CELLAR AS PER PLAN. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q08018515-I1
10/13/2022
Special inspection requirement — Fire-Resistance Rated Construction
NITHIN JOHN
10/10/2022
Special inspection requirement — Final
NITHIN JOHN
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedCONTROL PLBG & HTG INC01/20/2023
DOB NOWGeneral ConstructionSigned-offHENRYSMITH PROPERTY MGMT12/07/2022
Nothing on file for this building.
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
05/25/2023Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
05/25/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
04/28/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 3
DateRequirementInspectorRole
12/08/2022Fire-Resistant Penetrations and JointsNITHIN JOHNspecial
10/13/2022Fire-Resistance Rated ConstructionNITHIN JOHNprogress
10/10/2022FinalNITHIN JOHNprogress
▾Documents — 9 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/25/2026Q08052203-I1Request digital key ↗
08/15/2026Q08018515-I1Request digital key ↗
▸Seals & Professional Certifications5
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/25/2026Q08018515-I1Open ↗
08/13/2026Q08052203-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
08/26/2026Q08018515-I1Open ↗
08/26/2026Q08018515-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/31/2026Q08052203-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/15/2026Q08018515-I1Open ↗
08/13/2026Q08052203-I1Open ↗