← Back
Two family converted from one family
62-23 82 STREET
QUEENS · BIN 4068469
💬 Discuss this project
1940Year Built
2Stories
B3Building Class
R4AZoning
1,364 sfGross Floor Area
2Units
1 Open Violation ▸
Two family converted from one family · 4,467 sf lot · 0.31 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
2 jobs · most recent 12/10/2025
General Wiring
FiledStatusContractorScope
12/10/2025CompleteAMPACITY ELECTRICAL INCGeneral Wiring
08/07/2025CompleteEFCO ELECTRICAL SERVI INCGeneral Wiring
Building Lifecycle
All (30)Filed (2)Permit Issued (5)Signed Off (2)Violation (1)Inspection (3)Objection (10)Special Inspection (7)
04/07/2026
Signed off — Alteration
PROPOSED VERTICAL AND HORIZONTAL ENLARGEMENT, NEW PORCH AREA. NO CHANGE TO USE, EGRESS OR OCCUPANCY.
Q01061533-I1
04/06/2026
Signed off — Alteration
ERECT CONSTRUCTION FENCE TO SAFE GUARD PROPERTY IN CONJUNCTION WITH ALT Q01061533. NO CHANGE TO THE USE, EGRESS, AND OCCUPANCY
Q01061548-I1
03/09/2026
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
01/20/2026
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
01/15/2026
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
08/18/2025
Permit issued — Foundation
Q01061533-I1-GC
06/18/2025
Violation issued (ECB, open)
Construction
02/26/2025
Permit issued — Structural
Q01061533-I1-ST
02/26/2025
Permit issued — Foundation
Q01061533-I1-FO
02/26/2025
Permit issued — Structural
Q01061533-I1-GC
01/28/2025
Permit issued — Construction Fence
Q01061548-I1-FN
09/19/2024
Objection resolved — Addressed
09/06/2024
Objection resolved — Addressed
08/23/2024
Objection raised — Structural
08/13/2024
Objection resolved — Addressed
08/13/2024
Objection resolved — Addressed
07/29/2024
Objection raised — Zoning
07/29/2024
Objection raised — Scope
07/02/2024
Objection resolved — Addressed
06/24/2024
Objection raised — Zoning
06/24/2024
Objection raised — Scope
06/11/2024
Filed — Alteration
PROPOSED VERTICAL AND HORIZONTAL ENLARGEMENT, NEW PORCH AREA. NO CHANGE TO USE, EGRESS OR OCCUPANCY.
Q01061533-I1
06/07/2024
Filed — Alteration
ERECT CONSTRUCTION FENCE TO SAFE GUARD PROPERTY IN CONJUNCTION WITH ALT Q01061533. NO CHANGE TO THE USE, EGRESS, AND OCCUPANCY
Q01061548-I1
06/05/2024
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
BRIAN FLYNN
06/05/2024
Special inspection requirement — Concrete - Cast-In-Place
Rajasekhar Sakhamuri
06/05/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Rajasekhar Sakhamuri
06/05/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
Rajasekhar Sakhamuri
06/05/2024
Special inspection requirement — Structural Wood Frame
Rajasekhar Sakhamuri
06/05/2024
Special inspection requirement — Final
Rajasekhar Sakhamuri
06/05/2024
Special inspection requirement — Footing and Foundation
Rajasekhar Sakhamuri
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
DMA CONTRACTING103/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
FRANK J QUATELA ARCHITECT P.C206/11/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Manetta architecture design pllc403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
DMA CONTRACTING INCGeneral Contractor704/09/2026
EFCO ELECTRICAL SERVI INCElectrical103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
TRIANGLE INSPECTION & TES7495106/11/2024
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWFoundationSigned-offDMA CONTRACTING INC08/18/2025
DOB NOWStructuralSigned-offDMA CONTRACTING INC02/26/2025
DOB NOWFoundationSigned-offDMA CONTRACTING INC02/26/2025
DOB NOWStructuralSigned-offDMA CONTRACTING INC02/26/2025
DOB NOWConstruction FenceSigned-offDMA CONTRACTING INC01/28/2025
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
03/09/2026Pass-Final General Construction Non-Directive 14PassView ↗
01/20/2026Fail-Final General Construction Non-Directive 14FailView ↗
01/15/2026Pass-Final General Construction Non-Directive 14PassView ↗
▾Special Inspection Requirements (DOB NOW) — 7
DateRequirementInspectorRole
06/05/2024Subsurface Investigations (Borings/Test Pits)BRIAN FLYNNspecial
06/05/2024Concrete - Cast-In-PlaceRajasekhar Sakhamurispecial
06/05/2024Fire-Resistant Penetrations and JointsRajasekhar Sakhamurispecial
06/05/2024Structural Stability – Alterations of existing buildingsRajasekhar Sakhamurispecial
06/05/2024Structural Wood FrameRajasekhar Sakhamuriprogress
06/05/2024FinalRajasekhar Sakhamuriprogress
06/05/2024Footing and FoundationRajasekhar Sakhamuriprogress
▾Documents — 18 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/22/2026Q01061548-I1Request digital key ↗
08/22/2026Q01061533-I1Request digital key ↗
▸Zoning, Tax Lot & Property Records1
▸DOB NOWZD1: DOB Zoning Diagram1
08/13/2026Q01061533-I1Open ↗
▸Seals & Professional Certifications9
▸DOB NOWSpecial Inspector Seal & Signature4
08/23/2026Q01061533-I1Open ↗
08/23/2026Q01061533-I1Open ↗
08/23/2026Q01061533-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProgress Inspector Seal & Signature3
08/23/2026Q01061533-I1Open ↗
08/23/2026Q01061533-I1Open ↗
08/23/2026Q01061533-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/22/2026Q01061533-I1Open ↗
08/13/2026Q01061548-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/22/2026Q01061533-I1Open ↗
▸Inspections & Test Reports2
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026Q01061533-I1Open ↗
▸DOB NOWSOIL REPORT1
08/13/2026Q01061533-I1Open ↗
▸Other Documents3
▸DOB NOWSite Survey: Initial1
08/13/2026Q01061533-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/13/2026Q01061533-I1Open ↗
▸DOB NOWPlot Diagram1
08/13/2026Q01061533-I1Open ↗