← Back
Primarily 2 family with 1 store or office
64-01 COOPER AVENUE
QUEENS · BIN 4087061
💬 Discuss this project
1915Year Built
3Stories
S2Building Class
R5BZoning
3,720 sfGross Floor Area
3Units
1 Open Violation ▸
Primarily 2 family with 1 store or office · 1,912 sf lot · 1.95 FAR built · Flood zone X
Locations of Work
Mechanical
Roof1p · 1 filing · 8 docs
Floor 11p · 1 filing · 8 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
S&E BRIDGE&SCAFFOLD LLC103/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
A M ENGINEERING SERVICES PC107/17/2024
CD ARCHITECT STUDIO, LLP105/14/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
J SIBAJA KITCHEN VENTILATION203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
TRINCHESE CONSTRUCTION INGeneral Contractor603/21/2026
DAIDONE, SElectrical103/21/2026
JOHN JR MARIElectrical103/21/2026
TREVOR DUNWELLElectrical103/21/2026
WHITE HALL RESTORATIONElectrical103/21/2026
J. SIBAJA KITCHEN AND VE*General Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
AM ENGINEERING SERVICES P7975107/17/2024
CD ARCHITECT STUDIO, LLP2573105/14/2024
Building Lifecycle
All (48)Filed (2)Permit Issued (4)Signed Off (2)Violation (10)Inspection (2)Objection (10)Special Inspection (18)
10/22/2024
Signed off — Alteration
UP-GRADE FOR EXISTING COMMERCIAL KITCHEN HOOD TYPE I IN EXISTING DELI GROCERY, NO CHANGE OR EGRESS OCCUPANCY
Q01075751-I1
08/14/2024
Signed off — Alteration
Q01022621-I1
08/14/2024
Permit issued — General Construction
Q01022621-I1-ST
08/13/2024
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
08/12/2024
Permit issued — Mechanical Systems
Q01075751-I1-MS
08/06/2024
Objection resolved — Addressed
08/01/2024
Permit issued — General Construction
Q01022621-I1-GC
08/01/2024
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
07/23/2024
Objection raised — Other
07/17/2024
Filed — Alteration
UP-GRADE FOR EXISTING COMMERCIAL KITCHEN HOOD TYPE I IN EXISTING DELI GROCERY, NO CHANGE OR EGRESS OCCUPANCY
Q01075751-I1
07/16/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
Albert Munoz
07/16/2024
Special inspection requirement — HVAC-R and service water heating system controls
Albert Munoz
07/16/2024
Special inspection requirement — HVAC-R and service water heating equipment
Albert Munoz
07/09/2024
Permit issued — Structural
Q01022621-I1-GC
07/02/2024
Special inspection requirement — Mechanical Systems
Albert Munoz
07/02/2024
Special inspection requirement — Final
Albert Munoz
05/23/2024
Objection raised — Fire_Protection
05/23/2024
Objection resolved — Addressed
05/23/2024
Objection raised — Fire_Protection
05/23/2024
Objection resolved — Addressed
05/23/2024
Objection raised — Zoning
05/23/2024
Objection resolved — Addressed
05/23/2024
Objection raised — Zoning
05/23/2024
Objection resolved — Addressed
05/14/2024
Filed — Alteration
Q01022621-I1
04/25/2024
Special inspection requirement — Fenestration and door U-factor and product ratings
Nat Costanza
04/25/2024
Special inspection requirement — Air barrier - visual inspection
Nat Costanza
04/25/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Nat Costanza
04/25/2024
Special inspection requirement — Fenestration air leakage
Nat Costanza
04/25/2024
Special inspection requirement — Permanent certificate
Nat Costanza
04/25/2024
Special inspection requirement — Lighting in dwelling units
Nat Costanza
04/25/2024
Special inspection requirement — Insulation placement and R values
Nat Costanza
04/25/2024
Special inspection requirement — Energy Code Compliance Inspections
Nat Costanza
04/25/2024
Special inspection requirement — Fire-Resistance Rated Construction
Nat Costanza
04/25/2024
Special inspection requirement — Structural Wood Frame
Nat Costanza
04/25/2024
Special inspection requirement — Fenestration areas
Nat Costanza
03/19/2024
Special inspection requirement — Final
Nat Costanza
03/19/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
Nat Costanza
08/10/2009
Violation issued (ECB, closed)
Unknown
08/10/2009
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
11/20/2007
Violation issued (ECB, closed)
Quality of Life
03/26/2002
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/11/2001
Violation issued (DOB, closed)
VW*-VIOLATION - WORK W/O PERMIT DISMISSED
03/11/2001
Violation issued (ECB, closed)
Quality of Life
03/11/2001
Violation issued (ECB, closed)
Quality of Life
02/14/2001
Violation issued (ECB, closed)
Quality of Life
02/14/2001
Violation issued (DOB, closed)
VW*-VIOLATION - WORK W/O PERMIT DISMISSED
05/10/1990
Violation issued (ECB, closed)
Boilers
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offTRINCHESE CONSTRUCTION IN08/14/2024
DOB NOWMechanical SystemsSigned-offJ. SIBAJA KITCHEN AND VE*08/12/2024
DOB NOWGeneral ConstructionSigned-offTRINCHESE CONSTRUCTION IN08/01/2024
DOB NOWStructuralSigned-offTRINCHESE CONSTRUCTION IN07/09/2024
BISEQISSUEDWNS GENERAL CONSTRUCTION CORP06/06/2007
BISEQISSUEDWNS GENERAL CONSTRUCTION CORP06/06/2007
BISEQISSUEDS&E BRIDGE & SCAFFOLD LLC.05/31/2007
BISEQISSUEDS&E BRIDGE & SCAFFOLD LLC.05/31/2007
BISFPISSUEDNEW YORK BUISNESS FIRE SYSTEM IN12/23/2005
Nothing on file for this building.
▾Field Inspections (DOB CAP) — 2
DateTypeResultReport
08/13/2024Pass-Final General Construction Non-Directive 14PassView ↗
08/01/2024Fail-Final General Construction Non-Directive 14FailView ↗
▾Special Inspection Requirements (DOB NOW) — 18
DateRequirementInspectorRole
07/16/2024HVAC-R and service water piping design and insulationAlbert Munozenergy_progress
07/16/2024HVAC-R and service water heating system controlsAlbert Munozenergy_progress
07/16/2024HVAC-R and service water heating equipmentAlbert Munozenergy_progress
07/02/2024Mechanical SystemsAlbert Munozspecial
07/02/2024FinalAlbert Munozprogress
04/25/2024Fenestration and door U-factor and product ratingsNat Costanzaenergy_progress
04/25/2024Air barrier - visual inspectionNat Costanzaenergy_progress
04/25/2024Fire-Resistant Penetrations and JointsNat Costanzaspecial
04/25/2024Fenestration air leakageNat Costanzaenergy_progress
04/25/2024Permanent certificateNat Costanzaenergy_progress
04/25/2024Lighting in dwelling unitsNat Costanzaenergy_progress
04/25/2024Insulation placement and R valuesNat Costanzaenergy_progress
04/25/2024Energy Code Compliance InspectionsNat Costanzaprogress
04/25/2024Fire-Resistance Rated ConstructionNat Costanzaprogress
04/25/2024Structural Wood FrameNat Costanzaprogress
04/25/2024Fenestration areasNat Costanzaenergy_progress
03/19/2024FinalNat Costanzaprogress
03/19/2024Structural Stability – Alterations of existing buildingsNat Costanzaspecial
▾Documents — 26 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/22/2026Q01022621-I1Request digital key ↗
08/22/2026Q01075751-I1Request digital key ↗
▸Applications & Permits4
▸BISPLAN / WORK APPROVAL APPLICATION2
10/26/2009410163184Open ↗
09/09/2008410163184Open ↗
▸BISWORK PERMIT APPLICATION2
03/04/2009410163184Open ↗
10/09/2008410163184Open ↗
▸Seals & Professional Certifications13
▸DOB NOWProgress Inspector Seal & Signature6
08/30/2026Q01075751-I1Open ↗
08/30/2026Q01075751-I1Open ↗
08/30/2026Q01075751-I1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/13/2026Q01022621-I1Open ↗
08/13/2026Q01075751-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/30/2026Q01075751-I1Open ↗
08/24/2026Q01022621-I1Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
09/09/2008410163184Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM1
09/09/2008410163184Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
10/09/2008410163184Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/13/2026Q01022621-I1Open ↗
08/13/2026Q01075751-I1Open ↗
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'1
09/09/2008410163184Open ↗
▸Approvals, Objections & Sign-offs1
▸BISADMINISTRATIVE OBJECTIONS1
09/09/2008410163184Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
12/22/2009410163184Open ↗
09/09/2008410163184Open ↗
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1
09/09/2008410163184Open ↗