| Owner | Filings | Most Recent |
|---|---|---|
| EKB SERVICES | 42 | 07/08/2026 |
| BUILDERS CORP IMPACT | 1 | 03/22/2026 |
| TRES CONSTRUCTION | 1 | 03/21/2026 |
| Firm | Filings | Most Recent |
|---|---|---|
| GERALD CALIENDO ARCHITECTS | 6 | 12/13/2024 |
| STRUCTURAL ENGINEERING TECHNOLOGIES | 2 | 01/18/2024 |
| Representative | Filings | Most Recent |
|---|---|---|
| GERALD J. CALIENDO R.A., P.C. | 4 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| IMPACT BUILDERS CORP | General Contractor | 12 | 07/08/2026 |
| RECORD GROUP INC | General Contractor | 6 | 04/09/2026 |
| EKB SERVICES INC | General Contractor | 3 | 07/08/2026 |
| KGK ELECTRIC CORP. | Electrical | 2 | 03/22/2026 |
| SUPERIOR HVAC INC | General Contractor | 2 | 03/21/2026 |
| J. CAIAZZO PLBG & HTG COR | Plumbing | 2 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| WORLD DESIGN ARCHITECTURE | 9323 | 3 | 12/13/2024 |
| DOYUN KIM; RA | 7415 | 2 | 01/18/2024 |
| MARKANICS CORP | 4600 | 2 | 01/18/2024 |
| HRF SERVICES CORP | 5616 | 1 | 05/02/2022 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Mechanical Systems | Permit Issued | IMPACT BUILDERS CORP | 04/22/2026 |
| DOB NOW | Structural | Permit Issued | IMPACT BUILDERS CORP | 01/14/2026 |
| DOB NOW | Foundation | Permit Issued | RECORD GROUP INC | 01/13/2026 |
| DOB NOW | General Construction | Permit Issued | IMPACT BUILDERS CORP | 01/13/2026 |
| DOB NOW | General Construction | Permit Issued | RECORD GROUP INC | 08/04/2025 |
| DOB NOW | Mechanical Systems | Permit Issued | SUPERIOR HVAC INC | 03/13/2025 |
| DOB NOW | Plumbing | Permit Issued | J. CAIAZZO PLBG & HTG COR | 03/12/2025 |
| DOB NOW | General Construction | Permit Issued | IMPACT BUILDERS CORP | 01/13/2025 |
| DOB NOW | Foundation | Permit Issued | RECORD GROUP INC | 01/13/2025 |
| DOB NOW | Structural | Permit Issued | IMPACT BUILDERS CORP | 01/13/2025 |
| DOB NOW | Plumbing | Permit Issued | J. CAIAZZO PLBG & HTG COR | 04/29/2024 |
| DOB NOW | Structural | Permit Issued | IMPACT BUILDERS CORP | 02/20/2024 |
| DOB NOW | Foundation | Permit Issued | RECORD GROUP INC | 01/22/2024 |
| DOB NOW | General Construction | Permit Issued | IMPACT BUILDERS CORP | 01/18/2024 |
| DOB NOW | General Construction | Permit Issued | IMPACT BUILDERS CORP | 09/28/2023 |
| DOB NOW | General Construction | Permit Issued | EKB SERVICES INC | 07/08/2023 |
| DOB NOW | General Construction | Permit Issued | EKB SERVICES INC | 02/09/2023 |
| BIS | CC | ISSUED | TRES CONSTRUCTION LLC | 08/18/2003 |
| BIS | PL | ISSUED | JALCO PLUMBING & HEATING | 02/23/1999 |
| BIS | — | ISSUED | TRES CONSTRUCTION LLC | 11/24/1998 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 12/13/2024 | Permit Issued | IMPACT BUILDERS CORP | Heating and Air Conditioning Systems, Ventilation Systems | Heat / Cool Mitsubishi Electric SEZ-KD09NA4R1.TH 8,100 BTU · Vrf Indoor ×5 MXZ-SM48NAMHZ-U1 48,000 BTU · Heat Pump Outdoor ×3 MSZ-FS09NA-U1 9,000 BTU · Split System ×2 SVZ-KP12NA 12,000 BTU · Fan Coil Indoor ×2 SVZ-KP24NA 24,000 BTU · Fan Coil Indoor ×2 2 13,600 BTU ×1 MSZ-EF09NAS-U2 9,000 BTU · Split System ×1 MSZ-EF15NAB-U2 15,000 BTU · Split System ×1 MXZ-SM36NAMHZ-U1 36,000 BTU · Heat Pump Outdoor ×1 — SVZ-KP18NA 18,000 BTU ×1 Ventilation Broan QTXE110 110 CFM · Exhaust Fan ×8 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 12/13/2024 | Permit Issued | J. CAIAZZO PLBG & HTG COR | Gas, Water/Sanitary |
| 05/02/2024 | Permit Issued | J. CAIAZZO PLBG & HTG COR | Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 03/26/2025 | Permit Issued | KGK ELECTRIC CORP. | General Wiring |
| 03/31/2023 | Cancelled | TRIZA ELECTRICAL CORP | General Wiring |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 05/02/2024 | Permit Issued | IMPACT BUILDERS CORP | Wood |
| Date | Type | Result | Report |
|---|---|---|---|
| 06/12/2026 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 04/13/2026 | Certified Remove/Cap - work done in accordance with code | Certified | View ↗ |
| 03/27/2025 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 03/19/2025 | Certified Remove/Cap - work done in accordance with code | Certified | View ↗ |
| 03/19/2025 | Certified Water and Sanitary-WS-Fixtures-Finish | Certified | View ↗ |
| 07/17/2024 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 11/01/2023 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 10/25/2023 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 07/25/2023 | Fail-Final PL - Up to 3 Requested Floors | Fail | View ↗ |
| 07/12/2023 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 02/03/2025 | Energy Code Compliance Inspections | William Alicea | progress |
| 12/19/2024 | Lighting in dwelling units | William Alicea | energy_progress |
| 12/11/2024 | Energy Code Compliance Inspections | William Alicea | progress |
| 12/11/2024 | HVAC-R and service water piping design and insulation | William Alicea | energy_progress |
| 12/11/2024 | HVAC-R and service water heating system controls | William Alicea | energy_progress |
| 12/11/2024 | HVAC-R and service water heating equipment | William Alicea | energy_progress |
| 11/15/2024 | Structural Stability – Alterations of existing buildings | William Alicea | special |
| 08/01/2024 | Fireplaces | William Alicea | energy_progress |
| 07/31/2024 | HVAC-R and service water piping design and insulation | William Alicea | energy_progress |
| 07/31/2024 | HVAC-R and service water heating system controls | William Alicea | energy_progress |
| 07/31/2024 | HVAC-R and service water heating equipment | William Alicea | energy_progress |
| 07/31/2024 | Final | William Alicea | progress |
| 07/31/2024 | Mechanical Systems | William Alicea | special |
| 07/29/2024 | Fire-Resistant Penetrations and Joints | William Alicea | special |
| 02/07/2024 | Structural Stability – Alterations of existing buildings | DOYUN KIM | special |
| 02/07/2024 | Structural Wood Frame | DOYUN KIM | progress |
| 02/07/2024 | Post-installed Anchors | Malcolm Barkan | special |
| 12/08/2023 | Concrete - Cast-In-Place | DOYUN KIM | special |
| 12/08/2023 | Post-installed Anchors | Malcolm Barkan | special |
| 12/08/2023 | Structural Stability – Alterations of existing buildings | DOYUN KIM | special |
| 12/08/2023 | Subgrade Inspections | DOYUN KIM | special |
| 12/08/2023 | Subsurface Conditions – Fill Placement & In-Place Density | DOYUN KIM | special |
| 12/08/2023 | Subsurface Investigations (Borings/Test Pits) | GEORGE CAMBOURAKIS | special |
| 12/08/2023 | Final | JEFFREY BELL | progress |
| 12/08/2023 | Footing and Foundation | DOYUN KIM | progress |