| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 05/19/2022 | $1.1M | — | Private party → Private party | $612/sf building |
| Firm | Filings | Most Recent |
|---|---|---|
| CL ENGINEERING P.C. | 6 | 07/15/2024 |
| Representative | Filings | Most Recent |
|---|---|---|
| H J BUILDING CONSULTING | 12 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| HENG YIP CONSTRUCTION COR | General Contractor | 4 | 03/21/2026 |
| FLYTIGER P & H LTD | Plumbing | 2 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| CL ENGINEERING P.C. | 6781 | 5 | 07/15/2024 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Plumbing | Signed-off | FLYTIGER P & H LTD | 04/21/2023 |
| DOB NOW | Construction Fence | Signed-off | HENG YIP CONSTRUCTION COR | 11/15/2022 |
| DOB NOW | Plumbing | Signed-off | FLYTIGER P & H LTD | 09/06/2022 |
| DOB NOW | General Construction | Permit Issued | HENG YIP CONSTRUCTION COR | 09/03/2022 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 07/15/2024 | Signed-off | FLYTIGER P & H LTD | Gas, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 06/27/2023 | Complete | HI-RITE ELECTRIC CORP | General Wiring, Lighting |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 07/15/2024 | Signed-off | FLYTIGER P & H LTD | Fence |
| Date | Type | Result | Report |
|---|---|---|---|
| 06/26/2023 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 06/06/2023 | Certified Water and Sanitary-WS-Fixtures-Finish | Certified | View ↗ |
| 04/26/2023 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 12/30/2022 | Pass-Final PL - Up to 9 Requested Floors | Pass | View ↗ |
| 11/28/2022 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 11/18/2022 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 11/15/2022 | Fail-Final CND-Occupancy Inspection | Fail | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 10/16/2024 | Fire-Resistant Penetrations and Joints | CHRISTIAN LOZADA | special |
| 10/16/2024 | Lighting controls | CHRISTIAN LOZADA | energy_progress |
| 10/16/2024 | Lighting in dwelling units | CHRISTIAN LOZADA | energy_progress |
| 10/16/2024 | Maintenance information | CHRISTIAN LOZADA | energy_progress |
| 10/16/2024 | Permanent certificate | CHRISTIAN LOZADA | energy_progress |
| 10/16/2024 | Fenestration and door U-factor and product ratings | CHRISTIAN LOZADA | energy_progress |
| 10/16/2024 | Air barrier - visual inspection | CHRISTIAN LOZADA | energy_progress |
| 10/16/2024 | Fenestration areas | CHRISTIAN LOZADA | energy_progress |
| 10/16/2024 | Insulation placement and R values | CHRISTIAN LOZADA | energy_progress |
| 10/16/2024 | Interior lighting power | CHRISTIAN LOZADA | energy_progress |
| 10/16/2024 | Fenestration air leakage | CHRISTIAN LOZADA | energy_progress |
| 10/16/2024 | Energy Code Compliance Inspections | CHRISTIAN LOZADA | progress |
| 10/16/2024 | Fire-Resistance Rated Construction | CHRISTIAN LOZADA | progress |
| 07/15/2024 | Maintenance information | CHRISTIAN LOZADA | energy_progress |
| 07/15/2024 | Fire-Resistant Penetrations and Joints | CHRISTIAN LOZADA | special |
| 07/15/2024 | Energy Code Compliance Inspections | CHRISTIAN LOZADA | progress |
| 07/15/2024 | Fire-Resistance Rated Construction | CHRISTIAN LOZADA | progress |
| 07/15/2024 | Air barrier - visual inspection | CHRISTIAN LOZADA | energy_progress |
| 07/15/2024 | Fenestration and door U-factor and product ratings | CHRISTIAN LOZADA | energy_progress |
| 07/15/2024 | Insulation placement and R values | CHRISTIAN LOZADA | energy_progress |
| 07/15/2024 | Fenestration air leakage | CHRISTIAN LOZADA | energy_progress |
| 07/15/2024 | Fenestration areas | CHRISTIAN LOZADA | energy_progress |
| 07/15/2024 | Interior lighting power | CHRISTIAN LOZADA | energy_progress |
| 07/15/2024 | Lighting in dwelling units | CHRISTIAN LOZADA | energy_progress |
| 07/15/2024 | Permanent certificate | CHRISTIAN LOZADA | energy_progress |