← Back
Two stories - detached, small or mid-size
142-06 POPLAR AVENUE
QUEENS · BIN 4118190
💬 Discuss this project
1940Year Built
2.5Stories
A1Building Class
R2AZoning
1,394 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
Two stories - detached, small or mid-size · Owner of record: GEPE, LLC · 7,000 sf lot · 0.2 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
GEPE, LLC203/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
SU ARCHITECT, P.C.108/19/2025
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
PHD SERVICES CORPPlumbing106/28/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SU ARCHITECT PC6857108/19/2025
Building Lifecycle
All (16)Filed (1)Permit Issued (1)Signed Off (1)Violation (2)Inspection (5)Special Inspection (6)
07/08/2026
Signed off — Alteration
TO RESOLVE VIOLATION 39156484J AT CELLAR LEVEL WITH PLUMBING WORK TYPE AS PER PLAN FILED HEREWITH; NO CHANGE OF USE, EGRESS OR CERTIFICATE OF OCCUPANCY.
Q01273622-I1
04/22/2026
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
04/15/2026
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
04/15/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
04/15/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
04/13/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
03/11/2026
Permit issued — Plumbing
Q01273622-I1-PL
08/19/2025
Filed — Alteration
TO RESOLVE VIOLATION 39156484J AT CELLAR LEVEL WITH PLUMBING WORK TYPE AS PER PLAN FILED HEREWITH; NO CHANGE OF USE, EGRESS OR CERTIFICATE OF OCCUPANCY.
Q01273622-I1
08/19/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
QIANG SU
08/18/2025
Special inspection requirement — Tenant Protection Plan Compliance
QIANG SU
08/18/2025
Special inspection requirement — Energy Code Compliance Inspections
QIANG SU
08/18/2025
Special inspection requirement — HVAC-R and service water heating system controls
QIANG SU
08/18/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
QIANG SU
08/18/2025
Special inspection requirement — HVAC-R and service water heating equipment
QIANG SU
08/08/2025
Violation issued (ECB, closed)
Construction
07/29/2025
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offPHD SERVICES CORP03/11/2026
Nothing on file for this building.
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
04/22/2026Fail-Final PL - Up to 3 Requested FloorsFailView ↗
04/15/2026Certified Gas-Gas-Piping-RoughingCertifiedView ↗
04/15/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
04/15/2026Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
04/13/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 6
DateRequirementInspectorRole
08/19/2025Fire-Resistant Penetrations and JointsQIANG SUspecial
08/18/2025Tenant Protection Plan ComplianceQIANG SUspecial
08/18/2025Energy Code Compliance InspectionsQIANG SUprogress
08/18/2025HVAC-R and service water heating system controlsQIANG SUenergy_progress
08/18/2025HVAC-R and service water piping design and insulationQIANG SUenergy_progress
08/18/2025HVAC-R and service water heating equipmentQIANG SUenergy_progress
▾Documents — 7 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/19/2026Q01273622-I1Request digital key ↗
▸Seals & Professional Certifications5
▸DOB NOWProgress Inspector Seal & Signature2
08/28/2026Q01273622-I1Open ↗
08/28/2026Q01273622-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/28/2026Q01273622-I1Open ↗
08/28/2026Q01273622-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/19/2026Q01273622-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/19/2026Q01273622-I1Open ↗