← Back
Four families
13-37 BELL BOULEVARD
QUEENS · BIN 4132441
💬 Discuss this project
1970Year Built
3Stories
C3Building Class
R5Zoning
3,430 sfGross Floor Area
4Units
0 Open ViolationsFDNY Report ↗
Four families · Owner of record: TROPICAL 888 LLC · 2,200 sf lot · 1.56 FAR built · Flood zone X
Locations of Work
Mechanical
Floor 31p · 1 filing · 20 docs
Floor 2
Floor 1
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
TROPICAL 888 LLC103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
09/12/2023$1.2M—THE IRA KAZLOW TRUST → Private party$359/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
EAST + WEST ARCHITECTURE PC402/22/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
XUX CONSULTING803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
TLS CONSTRUCTION GROUP I*General Contractor407/08/2026
WATSON'S PLBG, HTG, & BDGPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
EAST+WEST ARCHITECTURE, P3269402/22/2024
Building Lifecycle
All (46)Filed (4)Permit Issued (3)Signed Off (2)Violation (3)Inspection (4)Special Inspection (30)
09/13/2024
Signed off — Alteration
Q00940575-I1
07/15/2024
Signed off — Alteration
Q00940575-S1
06/04/2024
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
05/31/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
BARBARA HESS
05/31/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
BARBARA HESS
05/31/2024
Special inspection requirement — Energy Code Compliance Inspections
BARBARA HESS
05/31/2024
Special inspection requirement — Final
BARBARA HESS
05/31/2024
Special inspection requirement — Air barrier - visual inspection
BARBARA HESS
05/31/2024
Special inspection requirement — HVAC-R and service water heating equipment
BARBARA HESS
05/31/2024
Special inspection requirement — Fenestration areas
BARBARA HESS
05/31/2024
Special inspection requirement — HVAC-R and service water heating system controls
BARBARA HESS
05/31/2024
Special inspection requirement — Fenestration air leakage
BARBARA HESS
05/31/2024
Special inspection requirement — Duct leakage testing, insulation and design
BARBARA HESS
05/31/2024
Special inspection requirement — Maintenance information
BARBARA HESS
05/31/2024
Special inspection requirement — Insulation placement and R values
BARBARA HESS
05/31/2024
Special inspection requirement — Permanent certificate
BARBARA HESS
05/31/2024
Special inspection requirement — Fenestration and door U-factor and product ratings
BARBARA HESS
05/31/2024
Special inspection requirement — Ventilation and air distribution system
BARBARA HESS
05/31/2024
Special inspection requirement — Mechanical Systems
BARBARA HESS
02/22/2024
Filed — Alteration
Q00940575-P2
02/22/2024
Filed — Alteration
Q00940575-P1
02/15/2024
Special inspection requirement — Mechanical Systems
BARBARA HESS
02/15/2024
Special inspection requirement — Energy Code Compliance Inspections
BARBARA HESS
02/15/2024
Special inspection requirement — Final
BARBARA HESS
02/15/2024
Special inspection requirement — Fenestration and door U-factor and product ratings
BARBARA HESS
02/15/2024
Special inspection requirement — Air barrier - visual inspection
BARBARA HESS
02/15/2024
Special inspection requirement — Fenestration areas
BARBARA HESS
02/15/2024
Special inspection requirement — Insulation placement and R values
BARBARA HESS
02/15/2024
Special inspection requirement — Maintenance information
BARBARA HESS
02/15/2024
Special inspection requirement — Permanent certificate
BARBARA HESS
02/15/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
BARBARA HESS
02/15/2024
Special inspection requirement — Fenestration air leakage
BARBARA HESS
02/15/2024
Special inspection requirement — Ventilation and air distribution system
BARBARA HESS
02/15/2024
Special inspection requirement — Duct leakage testing, insulation and design
BARBARA HESS
02/15/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
BARBARA HESS
01/05/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
01/05/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
01/03/2024
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
12/19/2023
Permit issued — Plumbing
Q00940575-S1-PL
11/29/2023
Permit issued — General Construction
Q00940575-I1-MS
11/29/2023
Permit issued — Mechanical Systems
Q00940575-I1-GC
10/17/2023
Filed — Alteration
Q00940575-S1
10/16/2023
Filed — Alteration
Q00940575-I1
02/15/2006
Violation issued (ECB, closed)
Construction
12/30/2005
Violation issued (ECB, closed)
Quality of Life
12/30/2005
Violation issued (ECB, closed)
Quality of Life
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offWATSON'S PLBG, HTG, & BDG12/19/2023
DOB NOWGeneral ConstructionSigned-offTLS CONSTRUCTION GROUP I*11/29/2023
DOB NOWMechanical SystemsSigned-offTLS CONSTRUCTION GROUP I*11/29/2023
1 project · most recent 01/24/2024
General Wiring
FiledStatusContractorScope
01/24/2024CompleteKJK ELECTRIC INCGeneral Wiring
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
06/04/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
01/05/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
01/05/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
01/03/2024Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 30
DateRequirementInspectorRole
05/31/2024HVAC-R and service water piping design and insulationBARBARA HESSenergy_progress
05/31/2024Fire-Resistant Penetrations and JointsBARBARA HESSspecial
05/31/2024Energy Code Compliance InspectionsBARBARA HESSprogress
05/31/2024FinalBARBARA HESSprogress
05/31/2024Air barrier - visual inspectionBARBARA HESSenergy_progress
05/31/2024HVAC-R and service water heating equipmentBARBARA HESSenergy_progress
05/31/2024Fenestration areasBARBARA HESSenergy_progress
05/31/2024HVAC-R and service water heating system controlsBARBARA HESSenergy_progress
05/31/2024Fenestration air leakageBARBARA HESSenergy_progress
05/31/2024Duct leakage testing, insulation and designBARBARA HESSenergy_progress
05/31/2024Maintenance informationBARBARA HESSenergy_progress
05/31/2024Insulation placement and R valuesBARBARA HESSenergy_progress
05/31/2024Permanent certificateBARBARA HESSenergy_progress
05/31/2024Fenestration and door U-factor and product ratingsBARBARA HESSenergy_progress
05/31/2024Ventilation and air distribution systemBARBARA HESSenergy_progress
05/31/2024Mechanical SystemsBARBARA HESSspecial
02/15/2024Mechanical SystemsBARBARA HESSspecial
02/15/2024Energy Code Compliance InspectionsBARBARA HESSprogress
02/15/2024FinalBARBARA HESSprogress
02/15/2024Fenestration and door U-factor and product ratingsBARBARA HESSenergy_progress
02/15/2024Air barrier - visual inspectionBARBARA HESSenergy_progress
02/15/2024Fenestration areasBARBARA HESSenergy_progress
02/15/2024Insulation placement and R valuesBARBARA HESSenergy_progress
02/15/2024Maintenance informationBARBARA HESSenergy_progress
02/15/2024Permanent certificateBARBARA HESSenergy_progress
Latest 25 of 30.
▾Documents — 44 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/24/2026Q00940575-I1Request digital key ↗
08/24/2026Q00940575-P2Request digital key ↗
08/24/2026Q00940575-P1Request digital key ↗
Showing 3 of 4 on file for this type
▸Applications & Permits2
▸BISPLAN / WORK APPROVAL APPLICATION2
02/15/2024402315259Open ↗
01/31/2024402315259Open ↗
▸Seals & Professional Certifications34
▸DOB NOWProgress Inspector Seal & Signature26
08/28/2026Q00940575-I1Open ↗
08/28/2026Q00940575-I1Open ↗
08/28/2026Q00940575-I1Open ↗
Showing 3 of 26 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/24/2026Q00940575-P1Open ↗
08/24/2026Q00940575-S1Open ↗
08/24/2026Q00940575-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
08/28/2026Q00940575-I1Open ↗
08/28/2026Q00940575-I1Open ↗
08/22/2026Q00940575-P2Open ↗
Showing 3 of 4 on file for this type
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/24/2026Q00940575-P1Open ↗
08/24/2026Q00940575-S1Open ↗
08/24/2026Q00940575-I1Open ↗
Showing 3 of 4 on file for this type