← Back
One family attached or semi-detached
153-10 77 AVENUE
QUEENS · BIN 4147518
💬 Discuss this project
1950Year Built
2Stories
A5Building Class
R4Zoning
1,260 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
One family attached or semi-detached · 1,800 sf lot · 0.7 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingCivil
Roof1p · 1 filing · 7 docs
Floor 212p · 2 filings · 20 docs
Floor 112p · 1 filing · 20 docs
Basement12p · 2 filings · 20 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
HAYM S. GROSS, ARCHITECT607/30/2024
RIKE TECH ASSOCIATES LLC205/25/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
BRITZ ENTERPRISES INC.1603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
UK 2 CONSTRUCTION CORPGeneral Contractor1404/09/2026
ASSURED BUILDERS INCGeneral Contractor307/08/2026
SPLEN CONSTRUCTION INCGeneral Contractor303/21/2026
G.M.A. PLUMBING & HEATINGPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
RIKE TECH ASSOCIATES LLC2965707/30/2024
Building Lifecycle
All (90)Filed (8)Permit Issued (12)Signed Off (2)Violation (2)Inspection (8)Objection (28)Special Inspection (30)
10/10/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
08/20/2025
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
03/06/2025
Signed off — Alteration
PLUMBING WORK IN CONJUNCTION WITH ALT Q00655112
Q00671731-I1
11/20/2024
Special inspection requirement — Protection of exposed foundation insulation
SYED RIZVI
11/20/2024
Special inspection requirement — Masonry
SYED RIZVI
11/20/2024
Special inspection requirement — Footing and Foundation
SYED RIZVI
11/20/2024
Special inspection requirement — Air barrier - visual inspection
SYED RIZVI
11/20/2024
Special inspection requirement — HVAC-R and service water heating system controls
SYED RIZVI
11/20/2024
Special inspection requirement — Structural Steel - High Strength Bolting
SYED RIZVI
11/20/2024
Special inspection requirement — Structural Steel - Details
SYED RIZVI
11/20/2024
Special inspection requirement — Fire-Resistance Rated Construction
SYED RIZVI
11/20/2024
Special inspection requirement — Interior lighting power
SYED RIZVI
11/20/2024
Special inspection requirement — Insulation placement and R values
SYED RIZVI
11/20/2024
Special inspection requirement — Fenestration air leakage
SYED RIZVI
11/20/2024
Special inspection requirement — Fenestration and door U-factor and product ratings
SYED RIZVI
11/20/2024
Special inspection requirement — Concrete - Cast-In-Place
SYED RIZVI
11/20/2024
Special inspection requirement — Mechanical Systems
SYED RIZVI
11/20/2024
Special inspection requirement — Structural Cold-Formed Steel
SYED RIZVI
11/20/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
SYED RIZVI
11/20/2024
Special inspection requirement — Subgrade Inspections
SYED RIZVI
11/20/2024
Special inspection requirement — Final
HAYM GROSS
11/20/2024
Special inspection requirement — Energy Code Compliance Inspections
SYED RIZVI
11/20/2024
Special inspection requirement — Structural Wood Frame
SYED RIZVI
11/20/2024
Special inspection requirement — Lighting in dwelling units
SYED RIZVI
11/20/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
SYED RIZVI
11/20/2024
Special inspection requirement — HVAC-R and service water heating equipment
SYED RIZVI
11/20/2024
Special inspection requirement — Fenestration areas
SYED RIZVI
11/20/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
SYED RIZVI
11/01/2024
Objection resolved — Addressed
11/01/2024
Objection resolved — Addressed
10/01/2024
Objection raised — Zoning
10/01/2024
Objection resolved — Addressed
08/14/2024
Objection raised — Zoning
08/14/2024
Objection raised — Inspections
07/30/2024
Filed — Alteration CO
APPLICATION FILED HEREWITH FOR FRONT AND REAR ADDITIONS AS PER PLANS; PLUMBING FILED SEPARATE
Q00655112-P3
06/28/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
SYED RIZVI
06/28/2024
Special inspection requirement — Concrete - Cast-In-Place
SYED RIZVI
06/28/2024
Special inspection requirement — Masonry
SYED RIZVI
06/28/2024
Special inspection requirement — Mechanical Systems
SYED RIZVI
06/28/2024
Special inspection requirement — Structural Cold-Formed Steel
SYED RIZVI
05/29/2024
Signed off — Alteration
Q00687627-I1
05/29/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
05/03/2024
Objection resolved — Addressed
05/03/2024
Objection resolved — Addressed
05/03/2024
Objection resolved — Addressed
05/03/2024
Objection resolved — Addressed
04/12/2024
Objection raised — Other
04/12/2024
Objection raised — Other
04/12/2024
Objection raised — Other
04/12/2024
Objection raised — Scope
04/01/2024
Filed — Alteration CO
APPLICATION FILED HEREWITH FOR FRONT AND REAR ADDITIONS AS PER PLANS; PLUMBING FILED SEPARATE
Q00655112-P2
03/14/2024
Inspection — Fail-Final CND-Occupancy Inspection
Fail
View inspection ↗
02/23/2024
Inspection — Fail-Final CND-Occupancy Inspection
Fail
View inspection ↗
05/25/2023
Filed — Alteration CO
APPLICATION FILED HEREWITH FOR FRONT AND REAR ADDITIONS AS PER PLANS; PLUMBING FILED SEPARATE
Q00655112-P1
05/25/2023
Filed — Alteration
PLUMBING WORK IN CONJUNCTION WITH ALT Q00655112
Q00671731-P1
05/01/2023
Permit issued — Construction Fence
Q00687627-I1-FN
04/27/2023
Permit issued — Foundation
Q00655112-I1-GC
04/03/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/09/2023
Inspection — Certification Failed Storm Drainage-ST-Piping-Underground
Certification Failed
View inspection ↗
03/09/2023
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
Latest 60 of 90 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWConstruction FenceSigned-offASSURED BUILDERS INC05/01/2023
DOB NOWFoundationPermit IssuedASSURED BUILDERS INC04/27/2023
DOB NOWConstruction FenceSigned-offUK 2 CONSTRUCTION CORP02/18/2023
DOB NOWFoundationPermit IssuedUK 2 CONSTRUCTION CORP02/18/2023
DOB NOWPlumbingSigned-offG.M.A. PLUMBING & HEATING02/01/2023
DOB NOWMechanical SystemsPermit IssuedUK 2 CONSTRUCTION CORP12/13/2022
DOB NOWStructuralPermit IssuedUK 2 CONSTRUCTION CORP12/09/2022
DOB NOWEarth WorkPermit IssuedUK 2 CONSTRUCTION CORP12/08/2022
DOB NOWGeneral ConstructionPermit IssuedUK 2 CONSTRUCTION CORP12/08/2022
DOB NOWFoundationPermit IssuedUK 2 CONSTRUCTION CORP11/14/2022
DOB NOWConstruction FenceSigned-offUK 2 CONSTRUCTION CORP11/04/2022
DOB NOWGeneral ConstructionPermit IssuedSPLEN CONSTRUCTION INC11/12/2021
1 project · most recent 07/30/2024
Air Conditioning Systems Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
07/30/2024Permit IssuedASSURED BUILDERS INCAir Conditioning Systems, Heating Systems, Ventilation Systems
Cooling
Carrier 1080000btu 1,080,000 BTU · Condensing Unit ×15
Heating
Navien 360000 720,000 BTU · Boiler ×10
Ventilation
Carrier 180000btu 108,000 BTU · Exhaust Fan ×45
1 project · most recent 01/22/2023
General Wiring
FiledStatusContractorScope
01/22/2023CompleteC & A ELECTRICAL CORPGeneral Wiring
1 project · most recent 07/30/2024
Steel Concrete Masonry
FiledStatusContractorScope
07/30/2024Permit IssuedASSURED BUILDERS INCSteel, Concrete, Masonry
1 project · most recent 07/30/2024
Earthwork
FiledStatusContractorScope
07/30/2024Permit IssuedASSURED BUILDERS INCEarthwork
▾Field Inspections (DOB CAP) — 8
DateTypeResultReport
10/10/2025Pass-Final CND-Occupancy InspectionPassView ↗
08/20/2025Fail-Final General Construction Non-Directive 14FailView ↗
05/29/2024Pass-Final CND-Occupancy InspectionPassView ↗
03/14/2024Fail-Final CND-Occupancy InspectionFailView ↗
02/23/2024Fail-Final CND-Occupancy InspectionFailView ↗
03/09/2023Certification Failed Storm Drainage-ST-Piping-UndergroundCertification FailedView ↗
03/09/2023Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
03/09/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 102
DateRequirementInspectorRole
11/20/2024HVAC-R and service water heating system controlsSYED RIZVIenergy_progress
11/20/2024Fire-Resistant Penetrations and JointsSYED RIZVIspecial
11/20/2024MasonrySYED RIZVIspecial
11/20/2024Structural Steel - High Strength BoltingSYED RIZVIspecial
11/20/2024Mechanical SystemsSYED RIZVIspecial
11/20/2024Concrete - Cast-In-PlaceSYED RIZVIspecial
11/20/2024Structural Cold-Formed SteelSYED RIZVIspecial
11/20/2024Structural Stability – Alterations of existing buildingsSYED RIZVIspecial
11/20/2024Structural Steel - DetailsSYED RIZVIspecial
11/20/2024Subgrade InspectionsSYED RIZVIspecial
11/20/2024FinalHAYM GROSSprogress
11/20/2024Fire-Resistance Rated ConstructionSYED RIZVIprogress
11/20/2024Footing and FoundationSYED RIZVIprogress
11/20/2024Energy Code Compliance InspectionsSYED RIZVIprogress
11/20/2024Structural Wood FrameSYED RIZVIprogress
11/20/2024Interior lighting powerSYED RIZVIenergy_progress
11/20/2024Lighting in dwelling unitsSYED RIZVIenergy_progress
11/20/2024HVAC-R and service water piping design and insulationSYED RIZVIenergy_progress
11/20/2024Insulation placement and R valuesSYED RIZVIenergy_progress
11/20/2024Air barrier - visual inspectionSYED RIZVIenergy_progress
11/20/2024Protection of exposed foundation insulationSYED RIZVIenergy_progress
11/20/2024HVAC-R and service water heating equipmentSYED RIZVIenergy_progress
11/20/2024Fenestration areasSYED RIZVIenergy_progress
11/20/2024Fenestration air leakageSYED RIZVIenergy_progress
11/20/2024Fenestration and door U-factor and product ratingsSYED RIZVIenergy_progress
Latest 25 of 102.
▾Documents — 78 on file (BIS + DOB NOW)
▸Plans & Drawings9
▸DOB NOWPlans/Sketch9
08/27/2026Q00612431-I1Request digital key ↗
08/26/2026Q00687627-I1Request digital key ↗
08/24/2026Q00671731-P1Request digital key ↗
Showing 3 of 9 on file for this type
▸Zoning, Tax Lot & Property Records7
▸DOB NOWZD1: DOB Zoning Diagram5
08/13/2026Q00655112-I1Open ↗
08/13/2026Q00655112-P1Open ↗
08/13/2026Q00655112-P3Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWHouse Number Verification: TOPO Stamp2
08/15/2026Q00655112-I1Open ↗
08/13/2026Q00655112-I1Open ↗
▸Seals & Professional Certifications30
▸DOB NOWProgress Inspector Seal & Signature15
08/31/2026Q00655112-P1Open ↗
08/31/2026Q00655112-P1Open ↗
08/31/2026Q00655112-P1Open ↗
Showing 3 of 15 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature9
08/26/2026Q00687627-I1Open ↗
08/24/2026Q00671731-I1Open ↗
08/24/2026Q00671731-P1Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature6
08/31/2026Q00655112-P1Open ↗
08/27/2026Q00655112-P4Open ↗
08/27/2026Q00655112-I1Open ↗
Showing 3 of 6 on file for this type
▸Safety & Tenant Protection6
▸DOB NOWStreet Tree Checklist5
08/13/2026Q00655112-P1Open ↗
08/13/2026Q00655112-I1Open ↗
08/13/2026Q00655112-P2Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026Q00655112-I1Open ↗
▸Environmental & Asbestos7
▸DOB NOWDEP ACP-5: Asbestos Assessment Report7
08/24/2026Q00671731-P1Open ↗
08/21/2026Q00655112-P4Open ↗
08/21/2026Q00655112-P1Open ↗
Showing 3 of 7 on file for this type
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis1
08/13/2026Q00655112-I1Open ↗
▸Other Documents18
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone5
08/13/2026Q00655112-P2Open ↗
08/13/2026Q00655112-I1Open ↗
08/13/2026Q00655112-P3Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWPlot Diagram5
08/13/2026Q00655112-P3Open ↗
08/13/2026Q00655112-I1Open ↗
08/13/2026Q00655112-P2Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWSite Survey: Initial5
08/13/2026Q00655112-I1Open ↗
08/13/2026Q00655112-P2Open ↗
08/13/2026Q00655112-P1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWAdjoining Owners Notification1
08/13/2026Q00655112-I1Open ↗
▸DOB NOWProject Specific General Liability (PGL1)1
08/13/2026Q00655112-I1Open ↗
▸DOB NOWFinal Survey1
08/13/2026Q00655112-I1Open ↗