← Back
Two stories - detached, small or mid-size
80-55 162 STREET
QUEENS · BIN 4148473
💬 Discuss this project
1920Year Built
2.5Stories
A1Building Class
R2Zoning
1,284 sfGross Floor Area
1Units
Two stories - detached, small or mid-size · 2,442 sf lot · 0.53 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbingGeneral
Floor 24p · 1 filing · 17 docs
Floor 14p · 1 filing · 17 docs
Cellar8p · 1 filing · 17 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
HANSA BUILDING ENGINEERING SERVICES402/11/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
MHR LALIA CONSTRUCTION COGeneral Contractor104/09/2026
L&J PLG & HTG CO OF NY INPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ASKON ARCHITECT, P.C.3596402/11/2026
Building Lifecycle
All (20)Filed (4)Permit Issued (2)Inspection (5)Special Inspection (9)
03/23/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
03/17/2026
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
02/20/2026
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
02/17/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Akeeb Shekoni
02/17/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
Akeeb Shekoni
02/17/2026
Special inspection requirement — Fire-Resistance Rated Construction
HANSA PERSAUD
02/17/2026
Special inspection requirement — Energy Code Compliance Inspections
HANSA PERSAUD
02/17/2026
Special inspection requirement — Final
HANSA PERSAUD
02/17/2026
Special inspection requirement — Insulation placement and R values
HANSA PERSAUD
02/17/2026
Special inspection requirement — Air barrier - visual inspection
HANSA PERSAUD
02/11/2026
Filed — Alteration
PROPOSED PLUMBING WORK-TYPE FILED IN-CONJUNCTION WITH JOB#: Q01274296-I1
Q01274296-P2
11/25/2025
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
11/13/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Akeeb Shekoni
11/12/2025
Filed — Alteration
PROPOSED PLUMBING WORK-TYPE FILED IN-CONJUNCTION WITH JOB#: Q01274296-I1
Q01274296-P1
11/05/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Akeeb Shekoni
09/24/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
09/17/2025
Permit issued — Plumbing
Q01274296-S1-PL
09/09/2025
Filed — Alteration
PROPOSED PLUMBING WORK-TYPE FILED IN-CONJUNCTION WITH JOB#: Q01274296-I1
Q01274296-S1
09/02/2025
Permit issued — General Construction
Q01274296-I1-GC-CX
08/20/2025
Filed — Alteration
PROPOSED PLUMBING WORK-TYPE FILED IN-CONJUNCTION WITH JOB#: Q01274296-I1
Q01274296-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedL&J PLG & HTG CO OF NY IN09/17/2025
DOB NOWGeneral ConstructionPermit IssuedMHR LALIA CONSTRUCTION CO09/02/2025
1 project · most recent 02/11/2026
Gas Water/Sanitary
FiledStatusContractorScope
02/11/2026Permit IssuedL&J PLG & HTG CO OF NY INGas, Water/Sanitary
1 project · most recent 02/11/2026
FiledStatusContractorScope
02/11/2026Permit IssuedL&J PLG & HTG CO OF NY IN2 scope_items
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
03/23/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
03/17/2026Fail-Final General Construction Non-Directive 14FailView ↗
02/20/2026Fail-Final General Construction Non-Directive 14FailView ↗
11/25/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
09/24/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 9
DateRequirementInspectorRole
02/17/2026Fire-Resistant Penetrations and JointsAkeeb Shekonispecial
02/17/2026Structural Stability – Alterations of existing buildingsAkeeb Shekonispecial
02/17/2026Fire-Resistance Rated ConstructionHANSA PERSAUDprogress
02/17/2026Energy Code Compliance InspectionsHANSA PERSAUDprogress
02/17/2026FinalHANSA PERSAUDprogress
02/17/2026Insulation placement and R valuesHANSA PERSAUDenergy_progress
02/17/2026Air barrier - visual inspectionHANSA PERSAUDenergy_progress
11/13/2025Fire-Resistant Penetrations and JointsAkeeb Shekonispecial
11/05/2025Fire-Resistant Penetrations and JointsAkeeb Shekonispecial
▾Documents — 17 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/17/2026Q01274296-P1Request digital key ↗
08/17/2026Q01274296-S1Request digital key ↗
08/17/2026Q01274296-I1Request digital key ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications9
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/17/2026Q01274296-S1Open ↗
08/17/2026Q01274296-I1Open ↗
08/17/2026Q01274296-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature3
08/27/2026Q01274296-I1Open ↗
08/24/2026Q01274296-S1Open ↗
08/23/2026Q01274296-P1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
08/27/2026Q01274296-I1Open ↗
08/27/2026Q01274296-I1Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/17/2026Q01274296-S1Open ↗
08/17/2026Q01274296-I1Open ↗
08/17/2026Q01274296-P2Open ↗
Showing 3 of 4 on file for this type