← Back
One story - permanent living quarter
65-48 174 STREET
QUEENS · BIN 4149370
💬 Discuss this project
1950Year Built
1.67Stories
A2Building Class
R2Zoning
1,782 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
One story - permanent living quarter · 6,000 sf lot · 0.3 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralPlumbingCivil
Permit Issued — active, not yet Signed-off
Roof2p · 1 filing · 9 docs
Floor 2Under Construction71p · 1 filing · 20 docs
Floor 1Under Construction70p · 1 filing · 20 docs
CellarUnder Construction71p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
AT HOME CONSTRUCTION103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
05/02/2017$960K—— → —$539/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
CITISCAPE CONSULTING LTD701/29/2025
TOM PETERSEN ARCHITECT, LLC110/29/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
A D BUILDING SOLUTIONS1403/21/2026
Streekout Solutions103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
AT HOME CONSTRUCTION LLCGeneral Contractor2107/08/2026
ELECTRICIAN NYC LLCElectrical103/22/2026
GREGG NY PLUMBING, INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
AA BUILDING & INSPECTION1519601/29/2025
THOMAS PETERSEN ARCHITECT7854110/29/2024
Building Lifecycle
All (74)Filed (8)Permit Issued (12)Signed Off (1)Violation (1)Inspection (8)Objection (14)Special Inspection (30)
06/15/2026
Permit issued — Structural
Q00503942-I1-GC
06/11/2026
Signed off — Alteration
The scope of work pertains exclusively to the installation of the solar system. Any additional tasks or activities should not be assumed as approved or permitted by the NYC Department of Buildings. No change to use, egress, or occupancy.
Q01134528-I1
03/06/2026
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
03/04/2026
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
01/28/2026
Permit issued — Construction Fence
Q00503942-S1-FN
10/15/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
04/09/2025
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
04/09/2025
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
04/09/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
04/09/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
04/02/2025
Permit issued — Earth Work
Q00503942-I1-EA
04/01/2025
Permit issued — General Construction
Q00503942-I1-ST
03/31/2025
Permit issued — Earth Work
Q00503942-I1-GC
03/31/2025
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
03/06/2025
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
Younes Abouyaala
03/06/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
Younes Abouyaala
03/06/2025
Special inspection requirement — HVAC-R and service water heating system controls
Younes Abouyaala
03/06/2025
Special inspection requirement — HVAC-R and service water heating equipment
Younes Abouyaala
03/06/2025
Special inspection requirement — Maintenance information
Younes Abouyaala
02/25/2025
Objection resolved — Addressed
02/13/2025
Objection raised — Other
02/07/2025
Permit issued — Construction Fence
Q00503942-S1-FN
01/29/2025
Filed — ALT-CO - New Building with Existing Elements to Remain
PLUMBING WORKTYPE IN CONJUNCTION TO ALT-CO APPLICATION Q00503942-i1.
Q00503942-P4
01/24/2025
Special inspection requirement — Insulation placement and R values
Younes Abouyaala
01/24/2025
Special inspection requirement — Structural Wood Frame
Younes Abouyaala
01/24/2025
Special inspection requirement — Subgrade Inspections
Younes Abouyaala
01/24/2025
Special inspection requirement — Structural Steel - Welding
Younes Abouyaala
01/24/2025
Special inspection requirement — Footing and Foundation
Younes Abouyaala
01/24/2025
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
Rajasekhar Sakhamuri
01/24/2025
Special inspection requirement — Electric vehicle service equipment requirements
Younes Abouyaala
01/24/2025
Special inspection requirement — Structural Steel - High Strength Bolting
Younes Abouyaala
01/24/2025
Special inspection requirement — Fenestration air leakage
Younes Abouyaala
01/24/2025
Special inspection requirement — Structural Steel - Details
Younes Abouyaala
01/24/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
Younes Abouyaala
01/24/2025
Special inspection requirement — Air barrier - visual inspection
Younes Abouyaala
01/24/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Younes Abouyaala
01/24/2025
Special inspection requirement — Permanent certificate
Younes Abouyaala
01/24/2025
Special inspection requirement — Maintenance information
Younes Abouyaala
01/24/2025
Special inspection requirement — Fenestration areas
Younes Abouyaala
01/24/2025
Special inspection requirement — Final
NAVEEN KUMAR
01/24/2025
Special inspection requirement — Interior lighting power
Younes Abouyaala
01/24/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
Younes Abouyaala
01/24/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
Younes Abouyaala
01/24/2025
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
Younes Abouyaala
01/24/2025
Special inspection requirement — Concrete - Cast-In-Place
Younes Abouyaala
01/08/2025
Filed — ALT-CO - New Building with Existing Elements to Remain
PLUMBING WORKTYPE IN CONJUNCTION TO ALT-CO APPLICATION Q00503942-i1.
Q00503942-P3
01/08/2025
Special inspection requirement — Concrete - Cast-In-Place
Younes Abouyaala
01/08/2025
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
Younes Abouyaala
01/08/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Younes Abouyaala
12/19/2024
Filed — ALT-CO - New Building with Existing Elements to Remain
PLUMBING WORKTYPE IN CONJUNCTION TO ALT-CO APPLICATION Q00503942-i1.
Q00503942-P2
11/29/2024
Objection resolved — Addressed
11/06/2024
Objection raised — Zoning
10/29/2024
Filed — Alteration
The scope of work pertains exclusively to the installation of the solar system. Any additional tasks or activities should not be assumed as approved or permitted by the NYC Department of Buildings. No change to use, egress, or occupancy.
Q01134528-I1
09/27/2024
Permit issued — Plumbing
Q00503942-S2-PL
05/14/2024
Filed — ALT-CO - New Building with Existing Elements to Remain
PLUMBING WORKTYPE IN CONJUNCTION TO ALT-CO APPLICATION Q00503942-i1.
Q00503942-P1
04/25/2024
Violation issued (ECB, closed)
Construction
04/11/2024
Permit issued — Structural
Q00503942-I1-ST
04/10/2024
Permit issued — Structural
Q00503942-I1-FO
04/09/2024
Permit issued — Foundation
Q00503942-I1-EA
04/02/2024
Permit issued — General Construction
Q00503942-I1-GC
Latest 60 of 74 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralPermit IssuedAT HOME CONSTRUCTION LLC06/15/2026
DOB NOWConstruction FencePermit IssuedAT HOME CONSTRUCTION LLC01/28/2026
DOB NOWEarth WorkPermit IssuedAT HOME CONSTRUCTION LLC04/02/2025
DOB NOWGeneral ConstructionPermit IssuedAT HOME CONSTRUCTION LLC04/01/2025
DOB NOWEarth WorkPermit IssuedAT HOME CONSTRUCTION LLC03/31/2025
DOB NOWConstruction FencePermit IssuedAT HOME CONSTRUCTION LLC02/07/2025
DOB NOWPlumbingPermit IssuedGREGG NY PLUMBING, INC09/27/2024
DOB NOWStructuralPermit IssuedAT HOME CONSTRUCTION LLC04/11/2024
DOB NOWStructuralPermit IssuedAT HOME CONSTRUCTION LLC04/10/2024
DOB NOWFoundationPermit IssuedAT HOME CONSTRUCTION LLC04/09/2024
DOB NOWGeneral ConstructionPermit IssuedAT HOME CONSTRUCTION LLC04/02/2024
DOB NOWConstruction FencePermit IssuedAT HOME CONSTRUCTION LLC02/07/2024
1 project · most recent 01/29/2025
Gas Storm Water/Sanitary
FiledStatusContractorScope
01/29/2025Permit IssuedGREGG NY PLUMBING, INCGas, Storm, Water/Sanitary
3 projects · most recent 11/17/2024
General Wiring
FiledStatusContractorScope
11/17/2024Permit IssuedELECTRICIAN NYC LLCGeneral Wiring
10/31/2024Permit IssuedELECTRICIAN NYC LLC—
10/04/2024CompleteMDC SECURITY AND ELEC'L—
1 project · most recent 01/29/2025
Steel Concrete Wood
FiledStatusContractorScope
01/29/2025Permit IssuedAT HOME CONSTRUCTION LLCSteel, Concrete, Wood
1 project · most recent 10/29/2024
FiledStatusContractorScope
10/29/2024——43 panels, 19.78 kw, 1,318 roof_area_sqft
1 project · most recent 01/29/2025
Fence
FiledStatusContractorScope
01/29/2025Permit IssuedAT HOME CONSTRUCTION LLCFence
1 project · most recent 01/29/2025
Earthwork
FiledStatusContractorScope
01/29/2025Permit IssuedAT HOME CONSTRUCTION LLCEarthwork
▾Field Inspections (DOB CAP) — 8
DateTypeResultReport
03/06/2026Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
03/04/2026Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
10/15/2025Pass-Final CND-Occupancy InspectionPassView ↗
04/09/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
04/09/2025Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
04/09/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
04/09/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
03/31/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 98
DateRequirementInspectorRole
03/06/2025Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationYounes Abouyaalaspecial
03/06/2025HVAC-R and service water heating system controlsYounes Abouyaalaenergy_progress
03/06/2025HVAC-R and service water heating equipmentYounes Abouyaalaenergy_progress
03/06/2025Maintenance informationYounes Abouyaalaenergy_progress
03/06/2025HVAC-R and service water piping design and insulationYounes Abouyaalaenergy_progress
01/24/2025Subsurface Investigations (Borings/Test Pits)Rajasekhar Sakhamurispecial
01/24/2025Structural Steel - High Strength BoltingYounes Abouyaalaspecial
01/24/2025Structural Stability – Alterations of existing buildingsYounes Abouyaalaspecial
01/24/2025Fire-Resistant Penetrations and JointsYounes Abouyaalaspecial
01/24/2025Footing and FoundationYounes Abouyaalaprogress
01/24/2025FinalNAVEEN KUMARprogress
01/24/2025Structural Wood FrameYounes Abouyaalaprogress
01/24/2025Electric vehicle service equipment requirementsYounes Abouyaalaenergy_progress
01/24/2025Insulation placement and R valuesYounes Abouyaalaenergy_progress
01/24/2025Fenestration air leakageYounes Abouyaalaenergy_progress
01/24/2025Fenestration and door U-factor and product ratingsYounes Abouyaalaenergy_progress
01/24/2025Interior lighting powerYounes Abouyaalaenergy_progress
01/24/2025Air barrier - visual inspectionYounes Abouyaalaenergy_progress
01/24/2025HVAC-R and service water piping design and insulationYounes Abouyaalaenergy_progress
01/24/2025Permanent certificateYounes Abouyaalaenergy_progress
01/24/2025Maintenance informationYounes Abouyaalaenergy_progress
01/24/2025Fenestration areasYounes Abouyaalaenergy_progress
01/24/2025Concrete - Cast-In-PlaceYounes Abouyaalaspecial
01/24/2025Structural Steel - DetailsYounes Abouyaalaspecial
01/24/2025Subgrade InspectionsYounes Abouyaalaspecial
Latest 25 of 98.
▾Documents — 78 on file (BIS + DOB NOW)
▸Plans & Drawings7
▸DOB NOWPlans/Sketch7
08/23/2026Q00503942-P3Request digital key ↗
08/23/2026Q00503942-P2Request digital key ↗
08/23/2026Q00503942-P1Request digital key ↗
Showing 3 of 7 on file for this type
▸Zoning, Tax Lot & Property Records4
▸DOB NOWZD1: DOB Zoning Diagram4
08/23/2026Q00503942-P3Open ↗
08/14/2026Q00503942-I1Open ↗
08/13/2026Q00503942-P2Open ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications39
▸DOB NOWProgress Inspector Seal & Signature20
09/01/2026Q00503942-S2Open ↗
08/29/2026Q01134528-I1Open ↗
08/29/2026Q01134528-I1Open ↗
Showing 3 of 20 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature11
09/01/2026Q00503942-S2Open ↗
08/29/2026Q01134528-I1Open ↗
08/29/2026Q01134528-I1Open ↗
Showing 3 of 11 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature7
08/23/2026Q00503942-P2Open ↗
08/23/2026Q00503942-P4Open ↗
08/23/2026Q00503942-P3Open ↗
Showing 3 of 7 on file for this type
▸BISAPPLICANT OWNER SIGNATURE1
08/24/2021440679482Open ↗
▸Trade Schedules & Equipment4
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)4
08/23/2026Q00503942-P3Open ↗
08/14/2026Q00503942-I1Open ↗
08/13/2026Q00503942-P2Open ↗
Showing 3 of 4 on file for this type
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/23/2026Q00503942-P3Open ↗
08/23/2026Q00503942-P2Open ↗
08/23/2026Q00503942-P1Open ↗
Showing 3 of 5 on file for this type
▸Inspections & Test Reports6
▸DOB NOWSOIL REPORT4
08/23/2026Q00503942-P3Open ↗
08/14/2026Q00503942-I1Open ↗
08/13/2026Q00503942-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWTR4 Test Report and Plot Diagram1
08/14/2026Q00503942-I1Open ↗
▸DOB NOWTR4 Plot Diagram1
08/14/2026Q00503942-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/21/2026Q01134528-I1Open ↗
▸Filing & Intake Forms2
▸BISEFILING JOB APPLICATION COVER SHEET1
08/24/2021440679482Open ↗
▸BISBPP: CHECKLIST IN LIEU OF PLANS-ALT31
08/24/2021440679482Open ↗
▸Other Documents10
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone4
08/23/2026Q00503942-P3Open ↗
08/14/2026Q00503942-I1Open ↗
08/13/2026Q00503942-P2Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSite Survey: Initial4
08/23/2026Q00503942-P3Open ↗
08/14/2026Q00503942-I1Open ↗
08/13/2026Q00503942-P1Open ↗
Showing 3 of 4 on file for this type
▸BISBPP - SUPPORTING DOCUMENTATION1
08/24/2021440679482Open ↗
▸DOB NOWAdjoining Owners Notification1
08/14/2026Q00503942-I1Open ↗