← Back
One family attached or semi-detached
67-34 174 STREET
QUEENS · BIN 4149692
💬 Discuss this project
1955Year Built
2Stories
A5Building Class
R4Zoning
2,346 sfGross Floor Area
1Units
One family attached or semi-detached · 2,320 sf lot · 1.01 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbing
Floor 26p · 1 filing · 20 docs
Floor 16p · 1 filing · 20 docs
Basement6p · 1 filing · 20 docs
1 job · most recent 10/31/2024
Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
10/31/2024Permit IssuedSHIN-YANG CONSTRUCTION INAir Conditioning Systems, Ventilation Systems
Cooling
Mitsubishi Electric MUZ-GL09NA-U1 12,200 BTU · Heat Pump Outdoor ×3
Ventilation
N/A N/A 100 CFM · Exhaust Fan ×4
1 job · most recent 10/31/2024
Gas Water/Sanitary
FiledStatusContractorScope
10/31/2024Signed-offL&M PLUMBING LLCGas, Water/Sanitary
1 job · most recent 11/12/2024
General Wiring
FiledStatusContractorScope
11/12/2024CompleteR & T ELECTRICAL CORPGeneral Wiring
Building Lifecycle
All (78)Filed (7)Permit Issued (4)Signed Off (3)Inspection (4)Objection (30)Special Inspection (30)
01/27/2026
Signed off — Alteration CO
Conversion of one family to two family . Obtain new C. of O
Q00957095-I1
10/06/2025
Signed off — Alteration CO
Conversion of one family to two family . Obtain new C. of O
Q00957095-S2
05/27/2025
Signed off — Alteration CO
Conversion of one family to two family . Obtain new C. of O
Q00957095-S1
05/20/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
05/15/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
01/28/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
11/12/2024
Special inspection requirement — Energy Code Compliance Inspections
Ling Li
11/12/2024
Special inspection requirement — Fenestration and door U-factor and product ratings
Ling Li
11/12/2024
Special inspection requirement — Air barrier - visual inspection
Ling Li
11/12/2024
Special inspection requirement — Fenestration air leakage
Ling Li
11/12/2024
Special inspection requirement — Insulation placement and R values
Ling Li
11/12/2024
Special inspection requirement — Fenestration areas
Ling Li
11/12/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Ling Li
11/12/2024
Special inspection requirement — Metering
Ling Li
11/12/2024
Special inspection requirement — Air barrier — testing
Ling Li
11/12/2024
Special inspection requirement — Preliminary
Ling Li
11/12/2024
Special inspection requirement — Fire-Resistance Rated Construction
Ling Li
11/08/2024
Special inspection requirement — Ventilation and air distribution system
Ling Li
11/08/2024
Special inspection requirement — Shutoff dampers
Ling Li
11/08/2024
Special inspection requirement — Maintenance information
Ling Li
11/08/2024
Special inspection requirement — HVAC-R and service water heating system controls
Ling Li
11/08/2024
Special inspection requirement — HVAC-R and service water heating system controls
Ling Li
11/08/2024
Special inspection requirement — Permanent certificate
Ling Li
11/08/2024
Special inspection requirement — Duct leakage testing, insulation and design
Ling Li
11/08/2024
Special inspection requirement — Final
Ling Li
11/08/2024
Special inspection requirement — Maintenance information
Ling Li
11/08/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Ling Li
11/08/2024
Special inspection requirement — Mechanical Systems
Ling Li
11/08/2024
Special inspection requirement — HVAC-R and service water heating equipment
Ling Li
11/08/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
Ling Li
11/08/2024
Special inspection requirement — Energy Code Compliance Inspections
Ling Li
11/08/2024
Special inspection requirement — Permanent certificate
Ling Li
11/08/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
Ling Li
11/08/2024
Special inspection requirement — HVAC-R and service water heating equipment
Ling Li
10/31/2024
Filed — Alteration CO
Conversion of one family to two family . Obtain new C. of O
Q00957095-P2
10/31/2024
Filed — Alteration CO
Conversion of one family to two family . Obtain new C. of O
Q00957095-P3
10/31/2024
Filed — Alteration CO
Conversion of one family to two family . Obtain new C. of O
Q00957095-P4
10/30/2024
Special inspection requirement — Metering
Ling Li
10/30/2024
Special inspection requirement — Fenestration areas
Ling Li
07/26/2024
Permit issued — Plumbing
Q00957095-S1-PL
07/20/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Water Test
Certified
View inspection ↗
07/09/2024
Filed — Alteration CO
Conversion of one family to two family . Obtain new C. of O
Q00957095-P1
05/20/2024
Permit issued — Plumbing
Q00957095-S1-PL
05/16/2024
Permit issued — Mechanical Systems
Q00957095-S2-MS
05/16/2024
Permit issued — General Construction
Q00957095-I1-GC
03/28/2024
Objection resolved — Addressed
03/26/2024
Objection raised — Energy
03/14/2024
Filed — Alteration CO
Conversion of one family to two family . Obtain new C. of O
Q00957095-S2
01/30/2024
Objection resolved — Addressed
01/22/2024
Objection raised — Energy
01/11/2024
Filed — Alteration CO
Conversion of one family to two family . Obtain new C. of O
Q00957095-S1
12/06/2023
Objection resolved — Addressed
12/06/2023
Objection resolved — Addressed
12/06/2023
Objection resolved — Addressed
12/06/2023
Objection resolved — Addressed
12/06/2023
Objection resolved — Addressed
12/06/2023
Objection resolved — Addressed
12/06/2023
Objection resolved — Addressed
12/06/2023
Objection resolved — Addressed
12/06/2023
Objection resolved — Addressed
Latest 60 of 78 events.
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
05/01/2017$850K—— → —$362/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
LI ARCHITECT ASSOCIATE, PLLC710/31/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
LI ARCHITECT ASSOCIATE203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SHIN-YANG CONSTRUCTION INGeneral Contractor207/08/2026
L&M PLUMBING LLCPlumbing207/08/2026
R & T ELECTRICAL CORPElectrical103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
LI ARCHITECT ASSOCIATE, P1104710/31/2024
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offL&M PLUMBING LLC07/26/2024
DOB NOWPlumbingSigned-offL&M PLUMBING LLC05/20/2024
DOB NOWMechanical SystemsSigned-offSHIN-YANG CONSTRUCTION IN05/16/2024
DOB NOWGeneral ConstructionPermit IssuedSHIN-YANG CONSTRUCTION IN05/16/2024
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
05/20/2025Pass-Final CND-Occupancy InspectionPassView ↗
05/15/2025Pass-Final CND-Occupancy InspectionPassView ↗
01/28/2025Pass-Final CND-Occupancy InspectionPassView ↗
07/20/2024Certified Water and Sanitary-WS-Sanitary Piping-Water TestCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 63
DateRequirementInspectorRole
11/12/2024Air barrier — testing Ling Lienergy_progress
11/12/2024Air barrier - visual inspectionLing Lienergy_progress
11/12/2024MeteringLing Lienergy_progress
11/12/2024Fenestration air leakageLing Lienergy_progress
11/12/2024Fenestration areasLing Lienergy_progress
11/12/2024Insulation placement and R valuesLing Lienergy_progress
11/12/2024Fenestration and door U-factor and product ratingsLing Lienergy_progress
11/12/2024Fire-Resistant Penetrations and JointsLing Lispecial
11/12/2024Fire-Resistance Rated ConstructionLing Liprogress
11/12/2024Energy Code Compliance InspectionsLing Liprogress
11/12/2024PreliminaryLing Liprogress
11/08/2024Shutoff dampersLing Lienergy_progress
11/08/2024Energy Code Compliance InspectionsLing Liprogress
11/08/2024Permanent certificateLing Lienergy_progress
11/08/2024HVAC-R and service water piping design and insulationLing Lienergy_progress
11/08/2024Maintenance informationLing Lienergy_progress
11/08/2024HVAC-R and service water heating system controlsLing Lienergy_progress
11/08/2024HVAC-R and service water heating equipmentLing Lienergy_progress
11/08/2024Mechanical SystemsLing Lispecial
11/08/2024FinalLing Liprogress
11/08/2024HVAC-R and service water heating equipmentLing Lienergy_progress
11/08/2024HVAC-R and service water piping design and insulationLing Lienergy_progress
11/08/2024Permanent certificateLing Lienergy_progress
11/08/2024HVAC-R and service water heating system controlsLing Lienergy_progress
11/08/2024Duct leakage testing, insulation and designLing Lienergy_progress
Latest 25 of 63.
▾Documents — 46 on file (BIS + DOB NOW)
▸Plans & Drawings7
▸DOB NOWPlans/Sketch7
08/23/2026Q00957095-P4Contact architect ↗
08/23/2026Q00957095-S2Contact architect ↗
08/23/2026Q00957095-P1Contact architect ↗
Showing 3 of 7 on file for this type
▸Zoning, Tax Lot & Property Records1
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026Q00957095-I1Open ↗
▸Seals & Professional Certifications28
▸DOB NOWProgress Inspector Seal & Signature14
09/01/2026Q00957095-P2Open ↗
09/01/2026Q00957095-P2Open ↗
08/30/2026Q00957095-P4Open ↗
Showing 3 of 14 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature7
09/01/2026Q00957095-P2Open ↗
08/30/2026Q00957095-P4Open ↗
08/28/2026Q00957095-S2Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature7
08/13/2026Q00957095-P2Open ↗
08/13/2026Q00957095-P1Open ↗
08/13/2026Q00957095-S2Open ↗
Showing 3 of 7 on file for this type
▸Environmental & Asbestos7
▸DOB NOWDEP ACP-5: Asbestos Assessment Report7
08/13/2026Q00957095-P1Open ↗
08/13/2026Q00957095-P4Open ↗
08/13/2026Q00957095-I1Open ↗
Showing 3 of 7 on file for this type
▸Other Documents3
▸DOB NOWProperty Ownership Certification2
08/13/2026Q00957095-P3Open ↗
08/13/2026Q00957095-I1Open ↗
▸DOB NOWFinal Survey1
08/13/2026Q00957095-I1Open ↗