← Back
One family attached or semi-detached
82-17 164 PLACE
QUEENS · BIN 4152382
💬 Discuss this project
1930Year Built
2Stories
A5Building Class
R4BZoning
1,152 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
One family attached or semi-detached · 2,392 sf lot · 0.48 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Permit Issued — active, not yet Signed-off
Floor 2Under Construction5p · 1 filing · 7 docs
Floor 1Under Construction5p · 1 filing · 7 docs
CellarUnder Construction5p · 1 filing · 7 docs
2 jobs · most recent 06/16/2026
General Wiring
FiledStatusContractorScope
06/16/2026Permit IssuedR & T ELECTRICAL CORPGeneral Wiring
04/18/2026Permit IssuedR & T ELECTRICAL CORPGeneral Wiring
Building Lifecycle
All (13)Filed (2)Permit Issued (2)Violation (3)Inspection (3)Special Inspection (3)
08/28/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
07/20/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
07/20/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
05/13/2026
Permit issued — Plumbing
Q01308545-S1-PL
05/07/2026
Permit issued — General Construction
Q01308545-I1-GC-CX
01/08/2026
Filed — Alteration CO
Q01308545-S1
01/07/2026
Special inspection requirement — Energy Code Compliance Inspections
DEZHANG FANG
01/07/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
DEZHANG FANG
01/07/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
DEZHANG FANG
10/28/2025
Filed — Alteration CO
Q01308545-I1
09/10/2025
Violation issued (ECB, closed)
Unknown
09/10/2025
Violation issued (ECB, closed)
Construction
04/15/2006
Violation issued (ECB, closed)
Zoning
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
07/21/2025$610K—— → —$530/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
FANG ARCHITECT201/08/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
INDESIGN STUDIO403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
GREAT ONE CONSTRUCTION LLGeneral Contractor107/08/2026
XH&RC PLBG AND HTG INCPlumbing105/15/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
FANG ARCHITECT5513201/08/2026
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedXH&RC PLBG AND HTG INC05/13/2026
DOB NOWGeneral ConstructionPermit IssuedGREAT ONE CONSTRUCTION LL05/07/2026
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
08/28/2026Pass-Final CND-Occupancy InspectionPassView ↗
07/20/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
07/20/2026Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 3
DateRequirementInspectorRole
01/07/2026Energy Code Compliance InspectionsDEZHANG FANGprogress
01/07/2026Fire-Resistant Penetrations and JointsDEZHANG FANGspecial
01/07/2026HVAC-R and service water piping design and insulationDEZHANG FANGenergy_progress
▾Documents — 8 on file (BIS + DOB NOW)
▸Zoning, Tax Lot & Property Records2
▸DOB NOWZD1: DOB Zoning Diagram1
08/13/2026Q01308545-I1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026Q01308545-I1Open ↗
▸Seals & Professional Certifications3
▸DOB NOWProgress Inspector Seal & Signature2
08/23/2026Q01308545-S1Open ↗
08/23/2026Q01308545-S1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/23/2026Q01308545-S1Open ↗
▸Other Documents3
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/13/2026Q01308545-I1Open ↗
▸DOB NOWPlot Diagram1
08/13/2026Q01308545-I1Open ↗
▸DOB NOWSite Survey: Initial1
08/13/2026Q01308545-I1Open ↗