← Back
One story - permanent living quarter
67-24 179 STREET
QUEENS · BIN 4153062
💬 Discuss this project
1945Year Built
1.67Stories
A2Building Class
R2AZoning
1,861 sfGross Floor Area
1Units
One story - permanent living quarter · 7,533 sf lot · 0.25 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralPlumbingGeneral
Floor 219p · 1 filing · 20 docs
Floor 120p · 1 filing · 20 docs
Cellar18p · 1 filing · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
06/17/2015$1.1M—— → —$602/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
SAFE CONSULTING LLC402/27/2025
AMINOV DESIGN ENGINEER, PC501/16/2025
M-CON ENGINEERING, PC107/12/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
A D BUILDING SOLUTIONS1803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
B.J. CONSTRUCTION OF NYGeneral Contractor504/09/2026
RAYMOND'S PLBG & HTG LLCPlumbing307/08/2026
SUSTAINABLE STRATEGIESGeneral Contractor104/09/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
S&S CONCRETE & SOIL TESTI1008802/27/2025
M-CON ENGINEERING7341107/12/2024
Building Lifecycle
All (118)Filed (10)Permit Issued (9)Signed Off (6)Inspection (5)Objection (58)Special Inspection (30)
08/07/2025
Signed off — ALT-CO - New Building with Existing Elements to Remain
SUBSEQUENT FILING FOR STRUCTURAL WORK
Q00890159-S2
07/31/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
07/21/2025
Permit issued — Plumbing
Q00890159-S2-PL
07/18/2025
Signed off — ALT-CO - New Building with Existing Elements to Remain
SUBSEQUENT FILING FOR STRUCTURAL WORK
Q00890159-S4
07/18/2025
Signed off — ALT-CO - New Building with Existing Elements to Remain
SUBSEQUENT FILING FOR STRUCTURAL WORK
Q00890159-S3
07/16/2025
Signed off — ALT-CO - New Building with Existing Elements to Remain
SUBSEQUENT FILING FOR STRUCTURAL WORK
Q00890159-S5
07/07/2025
Permit issued — Plumbing
Q00890159-S2-PL
06/29/2025
Signed off — ALT-CO - New Building with Existing Elements to Remain
SUBSEQUENT FILING FOR STRUCTURAL WORK
Q00890159-S1
03/18/2025
Special inspection requirement — Fenestration air leakage
GLEN LANGER
03/18/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
GLEN LANGER
03/18/2025
Special inspection requirement — Interior lighting power
GLEN LANGER
03/18/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
GLEN LANGER
03/18/2025
Special inspection requirement — Air barrier - visual inspection
GLEN LANGER
03/18/2025
Special inspection requirement — Air barrier — testing
GLEN LANGER
03/18/2025
Special inspection requirement — Final
GLEN LANGER
03/18/2025
Special inspection requirement — Energy Code Compliance Inspections
GLEN LANGER
03/18/2025
Special inspection requirement — Maintenance information
GLEN LANGER
03/18/2025
Special inspection requirement — Electric vehicle service equipment requirements
GLEN LANGER
03/18/2025
Special inspection requirement — HVAC-R and service water heating equipment
GLEN LANGER
03/18/2025
Special inspection requirement — Permanent certificate
GLEN LANGER
03/18/2025
Special inspection requirement — Mechanical Systems
GLEN LANGER
03/18/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
GLEN LANGER
03/18/2025
Special inspection requirement — Protection of exposed foundation insulation
GLEN LANGER
03/18/2025
Special inspection requirement — Ventilation and air distribution system
GLEN LANGER
03/18/2025
Special inspection requirement — Fenestration areas
GLEN LANGER
03/18/2025
Special inspection requirement — HVAC-R and service water heating system controls
GLEN LANGER
03/18/2025
Special inspection requirement — Insulation placement and R values
GLEN LANGER
03/18/2025
Special inspection requirement — Duct leakage testing, insulation and design
GLEN LANGER
03/10/2025
Objection resolved — Addressed
03/10/2025
Special inspection requirement — Structural Cold-Formed Steel
GLEN LANGER
03/10/2025
Special inspection requirement — Post-installed Anchors
GLEN LANGER
03/10/2025
Special inspection requirement — Final
GLEN LANGER
03/10/2025
Special inspection requirement — Concrete - Cast-In-Place
GLEN LANGER
03/10/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
GLEN LANGER
03/10/2025
Special inspection requirement — Structural Steel - Welding
GLEN LANGER
03/10/2025
Special inspection requirement — Structural Steel - High Strength Bolting
GLEN LANGER
03/10/2025
Special inspection requirement — Structural Steel - Details
GLEN LANGER
02/27/2025
Filed — ALT-CO - New Building with Existing Elements to Remain
SUBSEQUENT FILING FOR STRUCTURAL WORK
Q00890159-P3
02/24/2025
Objection resolved — Addressed
02/24/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
GLEN LANGER
02/24/2025
Special inspection requirement — Final
GLEN LANGER
02/23/2025
Objection resolved — Addressed
02/23/2025
Objection resolved — Addressed
02/23/2025
Objection resolved — Addressed
02/23/2025
Objection resolved — Addressed
02/21/2025
Objection raised — Inspections
02/21/2025
Objection raised — Structural
02/21/2025
Objection raised — Structural
02/21/2025
Objection raised — Scope
02/21/2025
Objection raised — Zoning
01/30/2025
Objection raised — Admin
01/16/2025
Filed — ALT-CO - New Building with Existing Elements to Remain
SUBSEQUENT FILING FOR STRUCTURAL WORK
Q00890159-P2
12/03/2024
Filed — ALT-CO - New Building with Existing Elements to Remain
SUBSEQUENT FILING FOR STRUCTURAL WORK
Q00890159-P1
09/20/2024
Signed off — Alteration
INSTALLATION OF SOLAR ELECTRIC GENERATION SYSTEM FOR UTILITY INTERCONNECTION
Q01079865-I1
07/24/2024
Permit issued — Solar
Q01079865-I1-SL
07/12/2024
Filed — Alteration
INSTALLATION OF SOLAR ELECTRIC GENERATION SYSTEM FOR UTILITY INTERCONNECTION
Q01079865-I1
06/25/2024
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
04/17/2024
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
04/17/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
04/12/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
Latest 60 of 118 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offRAYMOND'S PLBG & HTG LLC07/21/2025
DOB NOWPlumbingSigned-offRAYMOND'S PLBG & HTG LLC07/07/2025
DOB NOWSolarSigned-offSUSTAINABLE STRATEGIES07/24/2024
DOB NOWFoundationSigned-offB.J. CONSTRUCTION OF NY11/09/2023
DOB NOWPlumbingSigned-offRAYMOND'S PLBG & HTG LLC11/08/2023
DOB NOWFoundationSigned-offB.J. CONSTRUCTION OF NY11/06/2023
DOB NOWStructuralSigned-offB.J. CONSTRUCTION OF NY11/06/2023
DOB NOWGeneral ConstructionPermit IssuedB.J. CONSTRUCTION OF NY11/03/2023
DOB NOWConstruction FenceSigned-offB.J. CONSTRUCTION OF NY11/02/2023
1 project · most recent 02/27/2025
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
02/27/2025Signed-offB.J. CONSTRUCTION OF NYHeating and Air Conditioning Systems
Heat / Cool
Mitsubishi Electric MXZ-SM60NAM-U1 60,000 BTU · Heat Pump Outdoor ×2
MXZ-SM60NAM1 60,000 BTU · Vrf Outdoor ×4
MXZ-SM48NAM2 48,000 BTU · Heat Pump Outdoor ×2
1 project · most recent 02/27/2025
Gas Storm Water/Sanitary
FiledStatusContractorScope
02/27/2025Signed-offRAYMOND'S PLBG & HTG LLCGas, Storm, Water/Sanitary
2 projects · most recent 10/05/2025
General Wiring
FiledStatusContractorScope
10/05/2025CompleteNAS ELECTRIC CORPGeneral Wiring
07/09/2024CompleteSOURCE ELECTRIC INC1 meters
1 project · most recent 02/27/2025
Steel Concrete
FiledStatusContractorScope
02/27/2025Signed-offRAYMOND'S PLBG & HTG LLCSteel, Concrete
1 project · most recent 02/27/2025
Fence
FiledStatusContractorScope
02/27/2025Signed-offRAYMOND'S PLBG & HTG LLCFence
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
07/31/2025Pass-Final CND-Occupancy InspectionPassView ↗
06/25/2024Certified Gas-Gas-Piping-RoughingCertifiedView ↗
04/17/2024Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
04/17/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
04/12/2024Pass-Final CND-Occupancy InspectionPassView ↗
▾Special Inspection Requirements (DOB NOW) — 84
DateRequirementInspectorRole
03/18/2025Electric vehicle service equipment requirementsGLEN LANGERenergy_progress
03/18/2025Air barrier — testing GLEN LANGERenergy_progress
03/18/2025HVAC-R and service water heating equipmentGLEN LANGERenergy_progress
03/18/2025Interior lighting powerGLEN LANGERenergy_progress
03/18/2025Maintenance informationGLEN LANGERenergy_progress
03/18/2025Mechanical SystemsGLEN LANGERspecial
03/18/2025Fire-Resistant Penetrations and JointsGLEN LANGERspecial
03/18/2025FinalGLEN LANGERprogress
03/18/2025Energy Code Compliance InspectionsGLEN LANGERprogress
03/18/2025Duct leakage testing, insulation and designGLEN LANGERenergy_progress
03/18/2025HVAC-R and service water piping design and insulationGLEN LANGERenergy_progress
03/18/2025Fenestration and door U-factor and product ratingsGLEN LANGERenergy_progress
03/18/2025Air barrier - visual inspectionGLEN LANGERenergy_progress
03/18/2025Fenestration air leakageGLEN LANGERenergy_progress
03/18/2025Permanent certificateGLEN LANGERenergy_progress
03/18/2025Protection of exposed foundation insulationGLEN LANGERenergy_progress
03/18/2025Ventilation and air distribution systemGLEN LANGERenergy_progress
03/18/2025Fenestration areasGLEN LANGERenergy_progress
03/18/2025HVAC-R and service water heating system controlsGLEN LANGERenergy_progress
03/18/2025Insulation placement and R valuesGLEN LANGERenergy_progress
03/10/2025Concrete - Cast-In-PlaceGLEN LANGERspecial
03/10/2025FinalGLEN LANGERprogress
03/10/2025Structural Cold-Formed SteelGLEN LANGERspecial
03/10/2025Post-installed AnchorsGLEN LANGERspecial
03/10/2025Structural Steel - WeldingGLEN LANGERspecial
Latest 25 of 84.
▾Documents — 76 on file (BIS + DOB NOW)
▸Plans & Drawings10
▸DOB NOWPlans/Sketch10
08/24/2026Q00890159-S4Request digital key ↗
08/24/2026Q00890159-S3Request digital key ↗
08/24/2026Q00890159-S2Request digital key ↗
Showing 3 of 10 on file for this type
▸Zoning, Tax Lot & Property Records4
▸DOB NOWZD1: DOB Zoning Diagram3
08/13/2026Q00890159-I1Open ↗
08/13/2026Q00890159-P1Open ↗
08/13/2026Q00890159-P2Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026Q00890159-I1Open ↗
▸Seals & Professional Certifications32
▸DOB NOWProgress Inspector Seal & Signature12
09/23/2026Q01079865-I1Open ↗
09/23/2026Q01079865-I1Open ↗
09/01/2026Q00890159-S2Open ↗
Showing 3 of 12 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature10
08/24/2026Q00890159-S4Open ↗
08/24/2026Q00890159-S3Open ↗
08/24/2026Q00890159-S2Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature10
09/23/2026Q01079865-I1Open ↗
09/01/2026Q00890159-S2Open ↗
09/01/2026Q00890159-I1Open ↗
Showing 3 of 10 on file for this type
▸Trade Schedules & Equipment3
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)3
08/13/2026Q00890159-P1Open ↗
08/13/2026Q00890159-I1Open ↗
08/13/2026Q00890159-P2Open ↗
▸Environmental & Asbestos9
▸DOB NOWDEP ACP-5: Asbestos Assessment Report9
08/24/2026Q00890159-S3Open ↗
08/24/2026Q00890159-S2Open ↗
08/24/2026Q00890159-I1Open ↗
Showing 3 of 9 on file for this type
▸Inspections & Test Reports6
▸DOB NOWSOIL REPORT2
08/13/2026Q00890159-S4Open ↗
08/13/2026Q00890159-S5Open ↗
▸DOB NOWGeotechnical Report (BC 1803.6)2
08/13/2026Q00890159-S4Open ↗
08/13/2026Q00890159-S5Open ↗
▸DOB NOWTR4 Test Report and Plot Diagram2
08/13/2026Q00890159-S5Open ↗
08/13/2026Q00890159-S4Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026Q01079865-I1Open ↗
▸Other Documents11
▸DOB NOWSite Survey: Initial3
08/13/2026Q00890159-P2Open ↗
08/13/2026Q00890159-P1Open ↗
08/13/2026Q00890159-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone3
08/13/2026Q00890159-I1Open ↗
08/13/2026Q00890159-P2Open ↗
08/13/2026Q00890159-P1Open ↗
▸DOB NOWProperty Ownership Certification3
08/24/2026Q00890159-I1Open ↗
08/24/2026Q00890159-P2Open ↗
08/24/2026Q00890159-P1Open ↗
▸DOB NOWAdjoining Owners Notification1
08/13/2026Q00890159-S5Open ↗
▸DOB NOWFinal Survey1
08/13/2026Q00890159-I1Open ↗