← Back
Two family converted from one family
45-29 204 STREET
QUEENS · BIN 4156621
💬 Discuss this project
1920Year Built
2.5Stories
B3Building Class
R3-1Zoning
3,576 sfGross Floor Area
2Units
0 Open ViolationsFDNY Report ↗
Two family converted from one family · 4,575 sf lot · 0.78 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Cellar2p · 2 filings · 15 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
06/23/2014$970K—Private party → Private party$271/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
FLUSHING ENGINEERING SERVICE PC303/02/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
K A INTERIOR DESIGN603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
CK COOLING & HEATING INCGeneral Contractor203/21/2026
TRI STATE PLBG & HTG INCPlumbing207/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
FLUSHING ENGINEERING SERV4373303/02/2022
Building Lifecycle
All (25)Filed (3)Permit Issued (3)Signed Off (2)Violation (7)Inspection (4)Special Inspection (6)
05/17/2022
Signed off — Alteration
Q00635853-I1
05/16/2022
Signed off — Alteration
REMOVE WATER & WASTE LINES FOR STALL SHOWER, SLOP SINK, AND WASHER; REMOVE GAS LINE AND GAS STOVE AND DRYER IN CELLAR, TO REMOVE VIOLATION# Q39050853K AND# Q39050854M. NO CHANGE IN USE, OCCUPANCY AND EGRESS.
Q00635857-I1
04/27/2022
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
03/31/2022
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
03/06/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
KY FU
03/06/2022
Special inspection requirement — Energy Code Compliance Inspections
KY FU
03/02/2022
Filed — Alteration
REMOVE WATER & WASTE LINES FOR STALL SHOWER, SLOP SINK, AND WASHER; REMOVE GAS LINE AND GAS STOVE AND DRYER IN CELLAR, TO REMOVE VIOLATION# Q39050853K AND# Q39050854M. NO CHANGE IN USE, OCCUPANCY AND EGRESS.
Q00635857-P1
03/02/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
KY FU
03/02/2022
Special inspection requirement — Energy Code Compliance Inspections
KY FU
01/27/2022
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
01/26/2022
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
01/05/2022
Permit issued — Plumbing
Q00635857-I1-PL
12/20/2021
Permit issued — Plumbing
Q00635857-I1-PL
12/18/2021
Permit issued — General Construction
Q00635853-I1-GC
11/23/2021
Filed — Alteration
Q00635853-I1
11/23/2021
Filed — Alteration
REMOVE WATER & WASTE LINES FOR STALL SHOWER, SLOP SINK, AND WASHER; REMOVE GAS LINE AND GAS STOVE AND DRYER IN CELLAR, TO REMOVE VIOLATION# Q39050853K AND# Q39050854M. NO CHANGE IN USE, OCCUPANCY AND EGRESS.
Q00635857-I1
11/23/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
KY FU
11/23/2021
Special inspection requirement — Energy Code Compliance Inspections
KY FU
11/10/2021
Violation issued (ECB, closed)
Construction
11/10/2021
Violation issued (ECB, closed)
Unknown
12/03/2019
Violation issued (ECB, closed)
Zoning
01/30/2008
Violation issued (ECB, closed)
Construction
10/04/2006
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
10/18/2005
Violation issued (ECB, closed)
Zoning
04/04/2000
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offDW PLUMBING INC01/05/2022
DOB NOWPlumbingSigned-offDW PLUMBING INC12/20/2021
DOB NOWGeneral ConstructionSigned-offCK COOLING HEATING12/18/2021
BISEQISSUEDTUH CORP.04/22/2008
BIS—ISSUEDTUH CORP.04/22/2008
BISEQISSUEDTUH CORP.07/17/2006
BIS—ISSUEDTUH CORP.07/17/2006
1 project · most recent 12/07/2021
General Wiring
FiledStatusContractorScope
12/07/2021CompleteKJK ELECTRIC INCGeneral Wiring
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
04/27/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
03/31/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
01/27/2022Pass-Final General Construction Non-Directive 14PassView ↗
01/26/2022Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 6
DateRequirementInspectorRole
03/06/2022Fire-Resistant Penetrations and JointsKY FUspecial
03/06/2022Energy Code Compliance InspectionsKY FUprogress
03/02/2022Fire-Resistant Penetrations and JointsKY FUspecial
03/02/2022Energy Code Compliance InspectionsKY FUprogress
11/23/2021Fire-Resistant Penetrations and JointsKY FUspecial
11/23/2021Energy Code Compliance InspectionsKY FUprogress
▾Documents — 15 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/27/2026Q00635853-I1Request digital key ↗
08/26/2026Q00635857-I1Request digital key ↗
08/26/2026Q00635857-P1Request digital key ↗
▸Seals & Professional Certifications9
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/26/2026Q00635857-P1Open ↗
08/26/2026Q00635857-I1Open ↗
08/13/2026Q00635853-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature3
09/01/2026Q00635857-P1Open ↗
09/01/2026Q00635857-I1Open ↗
08/25/2026Q00635853-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature3
09/01/2026Q00635857-P1Open ↗
09/01/2026Q00635857-I1Open ↗
08/25/2026Q00635853-I1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/26/2026Q00635857-I1Open ↗
08/26/2026Q00635857-P1Open ↗
08/13/2026Q00635853-I1Open ↗