← Back
One family attached or semi-detached
64-39 217 STREET
QUEENS · BIN 4162437
💬 Discuss this project
1950Year Built
2Stories
A5Building Class
R4-1Zoning
1,152 sfGross Floor Area
1Units
One family attached or semi-detached · 2,658 sf lot · 0.43 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
CELTIC WAY CONSULTING LLC208/07/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
HOME STYLE IMPROVEMENTS *General Contractor108/12/2026
Building Lifecycle
All (40)Filed (2)Permit Issued (1)Objection (8)Special Inspection (29)
08/11/2026
Permit issued — Construction Fence
Q01413264-S1-FN
08/07/2026
Filed — Alteration CO
Q01413264-S1
07/30/2026
Objection resolved — Resolved
07/16/2026
Objection resolved — Resolved
07/09/2026
Objection resolved — Resolved
07/09/2026
Objection resolved — Resolved
06/30/2026
Objection raised — Structural
06/30/2026
Objection raised — Energy
06/30/2026
Objection raised — Zoning
06/30/2026
Objection raised — Scope
06/07/2026
Filed — Alteration CO
Q01413264-I1
06/07/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
06/07/2026
Special inspection requirement — Mechanical Systems
06/07/2026
Special inspection requirement — Concrete - Cast-In-Place
06/07/2026
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
06/07/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
06/07/2026
Special inspection requirement — Heating Systems
06/07/2026
Special inspection requirement — Masonry
06/07/2026
Special inspection requirement — Structural Steel - Details
06/07/2026
Special inspection requirement — Subgrade Inspections
06/07/2026
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
06/07/2026
Special inspection requirement — Final
06/07/2026
Special inspection requirement — Footing and Foundation
06/07/2026
Special inspection requirement — Energy Code Compliance Inspections
06/07/2026
Special inspection requirement — Fire-Resistance Rated Construction
06/07/2026
Special inspection requirement — Structural Wood Frame
06/07/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
06/07/2026
Special inspection requirement — Interior lighting power
06/07/2026
Special inspection requirement — Permanent certificate
06/07/2026
Special inspection requirement — Fenestration areas
06/07/2026
Special inspection requirement — Air barrier - visual inspection
06/07/2026
Special inspection requirement — Maintenance information
06/07/2026
Special inspection requirement — Ventilation and air distribution system
06/07/2026
Special inspection requirement — Insulation placement and R values
06/07/2026
Special inspection requirement — HVAC-R and service water heating equipment
06/07/2026
Special inspection requirement — Electric vehicle service equipment requirements
06/07/2026
Special inspection requirement — HVAC-R and service water heating system controls
06/07/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
06/07/2026
Special inspection requirement — Metering
06/07/2026
Special inspection requirement — Fenestration air leakage
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWConstruction FencePermit IssuedHOME STYLE IMPROVEMENTS *08/11/2026
Nothing on file for this building.
▾Special Inspection Requirements (DOB NOW) — 29
DateRequirementInspectorRole
06/07/2026Structural Stability – Alterations of existing buildings—special
06/07/2026Mechanical Systems—special
06/07/2026Concrete - Cast-In-Place—special
06/07/2026Excavations - Sheeting, Shoring, and Bracing—special
06/07/2026Fire-Resistant Penetrations and Joints—special
06/07/2026Heating Systems—special
06/07/2026Masonry—special
06/07/2026Structural Steel - Details—special
06/07/2026Subgrade Inspections—special
06/07/2026Subsurface Investigations (Borings/Test Pits)—special
06/07/2026Final—progress
06/07/2026Footing and Foundation—progress
06/07/2026Energy Code Compliance Inspections—progress
06/07/2026Fire-Resistance Rated Construction—progress
06/07/2026Structural Wood Frame—progress
06/07/2026Fenestration and door U-factor and product ratings—energy_progress
06/07/2026Interior lighting power—energy_progress
06/07/2026Permanent certificate—energy_progress
06/07/2026Fenestration areas—energy_progress
06/07/2026Air barrier - visual inspection—energy_progress
06/07/2026Maintenance information—energy_progress
06/07/2026Ventilation and air distribution system—energy_progress
06/07/2026Insulation placement and R values—energy_progress
06/07/2026HVAC-R and service water heating equipment—energy_progress
06/07/2026Electric vehicle service equipment requirements—energy_progress
Latest 25 of 29.
▾Documents — 12 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/16/2026Q01413264-S1Request digital key ↗
08/15/2026Q01413264-I1Request digital key ↗
▸Zoning, Tax Lot & Property Records1
▸DOB NOWZD1: DOB Zoning Diagram1
08/15/2026Q01413264-I1Open ↗
▸Seals & Professional Certifications2
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/16/2026Q01413264-S1Open ↗
08/16/2026Q01413264-I1Open ↗
▸Safety & Tenant Protection1
▸DOB NOWStreet Tree Checklist1
08/15/2026Q01413264-I1Open ↗
▸Inspections & Test Reports2
▸DOB NOWTR4 Test Report and Plot Diagram1
08/15/2026Q01413264-I1Open ↗
▸DOB NOWSOIL REPORT1
08/15/2026Q01413264-I1Open ↗
▸Other Documents4
▸DOB NOWPlot Diagram1
08/15/2026Q01413264-I1Open ↗
▸DOB NOWProperty Ownership Certification1
08/15/2026Q01413264-I1Open ↗
▸DOB NOWSite Survey: Initial1
08/15/2026Q01413264-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/15/2026Q01413264-I1Open ↗