| Firm | Filings | Most Recent |
|---|---|---|
| MICHAEL KANG ARCHITECT P.C. | 3 | 02/21/2023 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| BIS | OT | ISSUED | PRO CUSTOM SOLAR LLC | 02/11/2021 |
| BIS | OT | ISSUED | NA | 07/14/1995 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 02/21/2023 | — | — | Heating and Air Conditioning Systems, Ventilation Systems |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 02/21/2023 | — | — | Storm, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 02/12/2021 | Complete | ISLAND ELECTRIC CORP | — |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 02/21/2023 | — | — | Wood |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 02/17/2023 | HVAC-R and service water piping design and insulation | — | energy_progress |
| 02/17/2023 | HVAC-R and service water heating system controls | — | energy_progress |
| 02/17/2023 | Energy Code Compliance Inspections | — | progress |
| 02/17/2023 | Fire-Resistant Penetrations and Joints | — | special |
| 02/17/2023 | Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation | — | special |
| 02/17/2023 | Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention Facilities | — | special |
| 01/16/2023 | Energy Code Compliance Inspections | — | progress |
| 01/16/2023 | Fire-Resistance Rated Construction | — | progress |
| 01/16/2023 | Structural Wood Frame | — | progress |
| 01/16/2023 | Protection of exposed foundation insulation | — | energy_progress |
| 01/16/2023 | Air barrier - visual inspection | — | energy_progress |
| 01/16/2023 | Ventilation and air distribution system | — | energy_progress |
| 01/16/2023 | Fenestration air leakage | — | energy_progress |
| 01/16/2023 | HVAC-R and service water piping design and insulation | — | energy_progress |
| 01/16/2023 | Fenestration areas | — | energy_progress |
| 01/16/2023 | HVAC-R and service water heating equipment | — | energy_progress |
| 01/16/2023 | Fenestration and door U-factor and product ratings | — | energy_progress |
| 01/16/2023 | Insulation placement and R values | — | energy_progress |
| 01/16/2023 | Maintenance information | — | energy_progress |
| 01/16/2023 | Interior lighting power | — | energy_progress |
| 01/16/2023 | Permanent certificate | — | energy_progress |
| 01/16/2023 | HVAC-R and service water heating system controls | — | energy_progress |
| 01/16/2023 | Air barrier — testing | — | energy_progress |
| 01/16/2023 | Concrete - Cast-In-Place | — | special |
| 01/16/2023 | Excavations - Sheeting, Shoring, and Bracing | — | special |