← Back
Training school
44-07 LITTLE NECK PARKWAY
QUEENS · BIN 4169414
💬 Discuss this project
1946Year Built
2Stories
W4Building Class
R2AZoning
2,970 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
Training school · Owner of record: HARBEST INC. · 6,880 sf lot · 0.43 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbing
Roof3p · 1 filing · 13 docs
Floor 21p · 1 filing · 13 docs
Floor 12p · 1 filing · 13 docs
1 job · most recent 08/21/2025
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
08/21/2025——Heating and Air Conditioning Systems
Heat / Cool
Lg ARNU363TAA4 40,000 BTU · Vrf Indoor ×5
ARUM072BTE5 81,000 BTU · Vrf Outdoor ×2
1 job · most recent 08/21/2025
Storm Water/Sanitary
FiledStatusContractorScope
08/21/2025——Storm, Water/Sanitary
1 job · most recent 08/21/2025
Steel Concrete Masonry
FiledStatusContractorScope
08/21/2025——Steel, Concrete, Masonry
Building Lifecycle
All (29)Filed (1)Violation (9)Objection (6)Special Inspection (13)
04/20/2026
Objection resolved — Open
04/06/2026
Objection resolved — Addressed
09/29/2025
Objection resolved — Addressed
09/22/2025
Objection raised — Scope
09/22/2025
Objection raised — Cost
09/22/2025
Objection raised — Scope
08/21/2025
Filed — Alteration CO
HORIZONTAL EXTENSION OF BUILDING AT REAR YARD. WORK INCLUDES 1 STORY REAR EXTENSION FROM EXISTING 2 STORY BUILDING FOR ADDITONAL CLASS ROOMS AT 1ST FLOOR. NEW CERTIFICATE OF OCCUPANCY.
Q01270946-I1
08/13/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
08/13/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
08/13/2025
Special inspection requirement — Energy Code Compliance Inspections
08/13/2025
Special inspection requirement — Fire-Resistance Rated Construction
08/13/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
08/13/2025
Special inspection requirement — Insulation placement and R values
08/13/2025
Special inspection requirement — Lighting controls
08/13/2025
Special inspection requirement — Interior lighting power
08/13/2025
Special inspection requirement — Fenestration areas
08/13/2025
Special inspection requirement — Fenestration air leakage
08/13/2025
Special inspection requirement — Air barrier - visual inspection
08/13/2025
Special inspection requirement — Maintenance information
08/13/2025
Special inspection requirement — Protection of exposed foundation insulation
06/20/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
04/06/2018
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/24/2017
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/01/2013
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
12/13/2011
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/13/2004
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/26/2002
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
08/29/1995
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/01/1993
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
HARBEST803/21/2026
READINGTOWN103/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
DESIGN GROUP IN H&K LLC108/21/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
DESIGN GROUP IN H K203/21/2026
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
BIS—ISSUEDHAREST INC.06/24/2019
BISPLISSUEDC.R.U. MECHAN & HEAT INC07/30/2014
BIS—ISSUEDSIN DO CONSTRUCTION INC07/23/2014
BISMHISSUEDSIN DO CONSTRUCTION INC12/27/2013
BISPLISSUEDPLUMBING & HTG DOCTOR INC09/17/2013
BIS—ISSUEDSIN DO CONSTRUCTION INC08/30/2013
BIS—ISSUEDCAGLIOTI CONSTRUCTION CO.04/24/1992
BISPLISSUEDJOHN MATRANGA PLG & HTG10/04/1991
BISEQISSUEDD-B-A CAGLIOT1 CONST. CO08/20/1991
BISOTISSUEDD-B-A CAGLIOT1 CONST. CO08/20/1991
▾Special Inspection Requirements (DOB NOW) — 13
DateRequirementInspectorRole
08/13/2025Structural Stability – Alterations of existing buildings—special
08/13/2025Fire-Resistant Penetrations and Joints—special
08/13/2025Energy Code Compliance Inspections—progress
08/13/2025Fire-Resistance Rated Construction—progress
08/13/2025Fenestration and door U-factor and product ratings—energy_progress
08/13/2025Insulation placement and R values—energy_progress
08/13/2025Lighting controls—energy_progress
08/13/2025Interior lighting power—energy_progress
08/13/2025Fenestration areas—energy_progress
08/13/2025Fenestration air leakage—energy_progress
08/13/2025Air barrier - visual inspection—energy_progress
08/13/2025Maintenance information—energy_progress
08/13/2025Protection of exposed foundation insulation—energy_progress
▾Documents — 104 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/19/2026Q01270946-S1Request digital key ↗
08/19/2026Q01270946-I1Request digital key ↗
08/19/2026Q01270946-S3Request digital key ↗
Showing 3 of 4 on file for this type
▸Applications & Permits16
▸BISPLAN / WORK APPROVAL APPLICATION8
08/12/2019421688604Open ↗
04/23/2019421688604Open ↗
07/29/2014421000384Open ↗
Showing 3 of 8 on file for this type
▸BISWORK PERMIT APPLICATION4
07/17/2019421688604Open ↗
08/08/2014421000384Open ↗
07/30/2014421000384Open ↗
Showing 3 of 4 on file for this type
▸BISCERTIFICATE OF OCCUPANCY: APPLICATION2
07/26/2019421688604Open ↗
08/07/2014421000384Open ↗
▸BISNon-Directive 14 Construction Sign Off Including Sign Applications1
04/14/2014420930452Open ↗
▸BISPLAN - WORK & PERMITS - SUPPPORTING DOCUMENTATION1
08/15/2014421000384Open ↗
▸Zoning, Tax Lot & Property Records2
▸DOB NOWZD1: DOB Zoning Diagram1
08/13/2026Q01270946-I1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/19/2026Q01270946-I1Open ↗
▸Seals & Professional Certifications11
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION5
08/15/2014421000384Open ↗
07/18/2014421000384Open ↗
04/14/2014420930452Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/13/2026Q01270946-S3Open ↗
08/13/2026Q01270946-S2Open ↗
08/13/2026Q01270946-S1Open ↗
Showing 3 of 4 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
12/24/2013420930452Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
12/24/2013420930452Open ↗
▸Trade Schedules & Equipment8
▸BISSELF-CERT PLUMBING NOTICE1
08/20/2014421000384Open ↗
▸BISEQUIPMENT USE APPLICATION/PERMIT1
04/14/2014420930452Open ↗
▸BISEQUIPMENT USE PERMITS1
04/14/2014420930452Open ↗
▸BISSCHEDULE B - PLUMBING1
04/04/2013420818949Open ↗
▸BISRPZ/DDCV TEST REPORT : GEN215B1
08/20/2014421000384Open ↗
▸BISFA - FDNY APPROVAL : FD-FAA1
07/09/2014420930764Open ↗
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE1
07/18/2014421000384Open ↗
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)1
08/13/2026Q01270946-I1Open ↗
▸Safety & Tenant Protection5
▸BISSTREET TREE CHECKLIST3
11/09/2018421688604Open ↗
07/18/2014421000384Open ↗
04/04/2013420818949Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/19/2026Q01270946-I1Open ↗
▸DOB NOWStreet Tree Checklist1
08/13/2026Q01270946-I1Open ↗
▸Environmental & Asbestos2
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
04/04/2013420818949Open ↗
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/19/2026Q01270946-I1Open ↗
▸Energy Compliance7
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS6
08/15/2014421000384Open ↗
07/30/2014421000384Open ↗
07/18/2014421000384Open ↗
Showing 3 of 6 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS1
04/14/2014420930452Open ↗
▸Approvals, Objections & Sign-offs14
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST5
08/12/2019421688604Open ↗
01/23/2015421000384Open ↗
08/15/2014421000384Open ↗
Showing 3 of 5 on file for this type
▸BISADMINISTRATIVE OBJECTIONS4
07/18/2014421000384Open ↗
12/24/2013420930452Open ↗
12/18/2013420930764Open ↗
Showing 3 of 4 on file for this type
▸BISSCHEDULE A - OCCUPANCY / USE3
04/15/2019421688604Open ↗
07/18/2014421000384Open ↗
04/04/2013420818949Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION2
04/14/2014420930452Open ↗
04/18/2013420818949Open ↗
▸Cost, Insurance & Ownership11
▸BISCOST AFFIDAVIT9
08/12/2019421688604Open ↗
11/09/2018421688604Open ↗
08/15/2014421000384Open ↗
Showing 3 of 9 on file for this type
▸BISDEPT OF FINANCE VERIFICATION2
08/12/2019421688604Open ↗
08/15/2014421000384Open ↗
▸Filing & Intake Forms16
▸BISADDITIONAL INFORMATION10
08/12/2019421688604Open ↗
08/07/2019421688604Open ↗
07/30/2019421688604Open ↗
Showing 3 of 10 on file for this type
▸BISEFILING COVER SHEET6
11/09/2018421688604Open ↗
07/18/2014421000384Open ↗
07/18/2014421000384Open ↗
Showing 3 of 6 on file for this type
▸Other Documents8
▸BISPLOT DIAGRAM3
08/12/2019421688604Open ↗
08/15/2014421000384Open ↗
04/04/2013420818949Open ↗
▸DOB NOWPlot Diagram2
08/19/2026Q01270946-I1Open ↗
08/13/2026Q01270946-I1Open ↗
▸DOB NOWProperty Ownership Certification1
08/13/2026Q01270946-I1Open ↗
▸DOB NOWSite Survey: Initial1
08/13/2026Q01270946-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/13/2026Q01270946-I1Open ↗