← Back
Two stories - detached, small or mid-size
48-10 HANFORD STREET
QUEENS · Douglaston-Little Neck · BIN 4169924
💬 Discuss this project
1910Year Built
2Stories
A1Building Class
R1-2Zoning
2,704 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
Two stories - detached, small or mid-size · 9,660 sf lot · 0.28 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
SPARTAN QUALITY CORP.503/22/2026
G5 CONCRETE103/22/2026
GS CONCRETE LLC103/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
VATCHE GHAZARIAN, PE103/07/2022
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
G5 CONCRETE, LLCGeneral Contractor303/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
INTERNATIONAL GEOTEHCNICA1795103/07/2022
IP CONCRETE TESTING AND I6252103/07/2022
Building Lifecycle
All (12)Filed (1)Permit Issued (1)Signed Off (1)Violation (2)Inspection (1)Special Inspection (6)
02/13/2023
Signed off — Alteration
Q00686195-I1
02/10/2023
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
04/22/2022
Violation issued (ECB, closed)
Construction
04/22/2022
Violation issued (ECB, closed)
Construction
04/14/2022
Permit issued — General Construction
Q00686195-I1-GC-CX
03/07/2022
Filed — Alteration
Q00686195-I1
02/23/2022
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
MICHAEL KARANTINIDIS, P.E.
02/23/2022
Special inspection requirement — Concrete - Cast-In-Place
INDARDEO PARBHUNATH
02/23/2022
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
INDARDEO PARBHUNATH
02/23/2022
Special inspection requirement — Subgrade Inspections
INDARDEO PARBHUNATH
02/23/2022
Special inspection requirement — Final
Younes Abouyaala
02/23/2022
Special inspection requirement — Footing and Foundation
Younes Abouyaala
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offG5 CONCRETE, LLC04/14/2022
BISPLISSUEDMAGNUM PLUMBING & HEATING CORP.10/16/1998
BIS—ISSUEDNA09/28/1998
Nothing on file for this building.
▾Field Inspections (DOB CAP) — 1
DateTypeResultReport
02/10/2023Pass-Final General Construction Non-Directive 14PassView ↗
▾Special Inspection Requirements (DOB NOW) — 6
DateRequirementInspectorRole
02/23/2022Subsurface Investigations (Borings/Test Pits)MICHAEL KARANTINIDIS, P.E.special
02/23/2022Concrete - Cast-In-PlaceINDARDEO PARBHUNATHspecial
02/23/2022Excavations - Sheeting, Shoring, and BracingINDARDEO PARBHUNATHspecial
02/23/2022Subgrade InspectionsINDARDEO PARBHUNATHspecial
02/23/2022FinalYounes Abouyaalaprogress
02/23/2022Footing and FoundationYounes Abouyaalaprogress
▾Documents — 11 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/26/2026Q00686195-I1Request digital key ↗
▸Seals & Professional Certifications7
▸DOB NOWSpecial Inspector Seal & Signature4
08/27/2026Q00686195-I1Open ↗
08/27/2026Q00686195-I1Open ↗
08/27/2026Q00686195-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProgress Inspector Seal & Signature2
08/27/2026Q00686195-I1Open ↗
08/27/2026Q00686195-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/13/2026Q00686195-I1Open ↗
▸Inspections & Test Reports3
▸DOB NOWTR4 Plot Diagram1
08/13/2026Q00686195-I1Open ↗
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026Q00686195-I1Open ↗
▸DOB NOWSOIL REPORT1
08/13/2026Q00686195-I1Open ↗