← Back
Two stories - detached, small or mid-size
81-28 252 STREET
QUEENS · BIN 4174777
💬 Discuss this project
1950Year Built
2Stories
A1Building Class
R2AZoning
1,200 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
Two stories - detached, small or mid-size · 4,000 sf lot · 0.3 FAR built · Flood zone X
Locations of Work
ArchitectureGeneral
Floor 21p · 1 filing · 7 docs
Floor 11p · 1 filing · 7 docs
Cellar1p · 1 filing · 7 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
02/04/2025$715K—Private party → Private party$596/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
MAZ DESIGN LLC112/22/2025
MA ENGINEERING, P.C.106/18/2025
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
MAZ 247 CORPGeneral Contractor104/09/2026
PLUMB-IT MECHANICAL INCPlumbing107/08/2026
Building Lifecycle
All (19)Filed (2)Permit Issued (2)Signed Off (1)Violation (2)Inspection (3)Objection (8)Special Inspection (1)
03/03/2026
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
02/24/2026
Signed off — Alteration
MINOR INTERIOR DRYWALL REMOVE REPLACE AND COSMETIC PAINING WITH NEW 2 FIXTURE BATHROOM AND LAUNDRYAREA AT CELLAR & LIFTING ECB VIOLATION #39141768J . LIFT STOP WORK ORDER.NO CHANGE USE EGRESS AND OCCUPANCY.
Q01230906-I1
02/23/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
02/23/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
02/09/2026
Permit issued — Plumbing
Q01230906-S1-PL
12/22/2025
Filed — Alteration
MINOR INTERIOR DRYWALL REMOVE REPLACE AND COSMETIC PAINING WITH NEW 2 FIXTURE BATHROOM AND LAUNDRYAREA AT CELLAR & LIFTING ECB VIOLATION #39141768J . LIFT STOP WORK ORDER.NO CHANGE USE EGRESS AND OCCUPANCY.
Q01230906-S1
09/05/2025
Permit issued — General Construction
Q01230906-I1-GC
08/14/2025
Objection resolved — Addressed
08/14/2025
Objection resolved — Addressed
08/05/2025
Objection raised — Cost
08/05/2025
Objection resolved — Addressed
07/21/2025
Objection raised — Admin
07/21/2025
Objection raised — Admin
07/09/2025
Objection resolved — Addressed
07/01/2025
Objection raised — Zoning
06/18/2025
Filed — Alteration
MINOR INTERIOR DRYWALL REMOVE REPLACE AND COSMETIC PAINING WITH NEW 2 FIXTURE BATHROOM AND LAUNDRYAREA AT CELLAR & LIFTING ECB VIOLATION #39141768J . LIFT STOP WORK ORDER.NO CHANGE USE EGRESS AND OCCUPANCY.
Q01230906-I1
05/23/2025
Special inspection requirement — Final
MOATEZ ALI
03/17/2025
Violation issued (ECB, closed)
Construction
03/17/2025
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offJVR PLBG AND HEATING INC02/09/2026
DOB NOWGeneral ConstructionSigned-offMAZ 247 CORP09/05/2025
1 project · most recent 12/22/2025
Water/Sanitary
FiledStatusContractorScope
12/22/2025Signed-offPLUMB-IT MECHANICAL INCWater/Sanitary
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
03/03/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
02/23/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
02/23/2026Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 1
DateRequirementInspectorRole
05/23/2025FinalMOATEZ ALIprogress
▾Documents — 7 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/19/2026Q01230906-S1Request digital key ↗
08/19/2026Q01230906-I1Request digital key ↗
▸Seals & Professional Certifications3
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/13/2026Q01230906-S1Open ↗
08/13/2026Q01230906-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
08/24/2026Q01230906-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/13/2026Q01230906-S1Open ↗
08/13/2026Q01230906-I1Open ↗