← Back
Primarily 2 family with 1 store or office
97-16 101 AVENUE
QUEENS · BIN 4189378
💬 Discuss this project
1920Year Built
3Stories
S2Building Class
R6BZoning
3,000 sfGross Floor Area
3Units
7 Open Violations 6 unresolved · 1 paperwork only ▸FDNY Report ↗
Primarily 2 family with 1 store or office · 2,017 sf lot · 1.49 FAR built · Flood zone X
Locations of Work
StructuralPlumbing
Permit Issued — active, not yet Signed-off
Floor 1Under Construction2p · 1 filing · 12 docs
CellarUnder Construction2p · 1 filing · 12 docs
1 job · most recent 04/24/2026
Air Conditioning Systems Heating Systems
FiledStatusContractorScopeMake / Model / Capacity
04/24/2026Permit IssuedC PLUS DESIGN GROUP INCAir Conditioning Systems, Heating Systems
Cooling
Blueridge BXALA60FC0 60,000 BTU · Fan Coil Indoor ×1
Heating
Blueridge BXL2A60UC0 60,000 BTU · Condensing Unit ×1
1 job · most recent 04/24/2026
Water/Sanitary
FiledStatusContractorScope
04/24/2026Permit IssuedWATERMARK PLUMBING CORPWater/Sanitary
2 jobs · most recent 03/24/2025
General Wiring Lighting
FiledStatusContractorScope
03/24/2025Permit Issued876 ELECTRICAL CORP3 meters, 1 new_meters
01/23/2025Permit IssuedBDS ELECTRIC CORP.General Wiring, Lighting
1 job · most recent 04/24/2026
Wood
FiledStatusContractorScope
04/24/2026Permit IssuedC PLUS DESIGN GROUP INCWood
Building Lifecycle
All (39)Filed (3)Permit Issued (2)Violation (15)Objection (6)Special Inspection (13)
06/26/2026
Permit issued — Structural
Q01200111-I1-GC-CX
04/24/2026
Filed — Alteration
FILING FOR INTERIOR RENOVATION OF EXISTING COMMERCIAL SPACE AT FIRST FLOOR AND CELLAR , AS PER PLANS. NO CHANGE IN USE EGRESS, OR OCCUPANCY.
Q01200111-S2
04/01/2026
Special inspection requirement — Mechanical Systems
04/01/2026
Special inspection requirement — Final
01/21/2026
Permit issued — Plumbing
Q01200111-S1-PL
05/05/2025
Objection resolved — Addressed
04/22/2025
Objection resolved — Addressed
04/16/2025
Objection raised — Cost
04/16/2025
Objection raised — Other
04/10/2025
Filed — Alteration
FILING FOR INTERIOR RENOVATION OF EXISTING COMMERCIAL SPACE AT FIRST FLOOR AND CELLAR , AS PER PLANS. NO CHANGE IN USE EGRESS, OR OCCUPANCY.
Q01200111-S1
04/03/2025
Objection resolved — Addressed
04/01/2025
Objection raised — Cost
03/27/2025
Filed — Alteration
FILING FOR INTERIOR RENOVATION OF EXISTING COMMERCIAL SPACE AT FIRST FLOOR AND CELLAR , AS PER PLANS. NO CHANGE IN USE EGRESS, OR OCCUPANCY.
Q01200111-I1
03/24/2025
Special inspection requirement — Energy Code Compliance Inspections
SERGEY BOLOTOV
03/24/2025
Special inspection requirement — Fire-Resistance Rated Construction
SERGEY BOLOTOV
03/24/2025
Special inspection requirement — Final
SERGEY BOLOTOV
03/24/2025
Special inspection requirement — Fenestration air leakage
SERGEY BOLOTOV
03/24/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
SERGEY BOLOTOV
03/24/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
SERGEY BOLOTOV
03/24/2025
Special inspection requirement — Insulation placement and R values
SERGEY BOLOTOV
03/24/2025
Special inspection requirement — Fenestration areas
SERGEY BOLOTOV
03/24/2025
Special inspection requirement — Lighting controls
SERGEY BOLOTOV
03/24/2025
Special inspection requirement — Air barrier - visual inspection
SERGEY BOLOTOV
03/24/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
SERGEY BOLOTOV
06/20/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
09/20/2019
Violation issued (ECB, closed)
Construction
09/20/2019
Violation issued (ECB, open)
Construction
04/06/2018
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
11/06/2015
Violation issued (HPD, open)
B
11/06/2015
Violation issued (HPD, closed)
B
11/06/2015
Violation issued (HPD, closed)
B
11/06/2015
Violation issued (HPD, closed)
B
11/06/2015
Violation issued (HPD, open)
B
10/01/2015
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
03/03/2015
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
03/21/2000
Violation issued (ECB, closed)
Boilers
08/29/1995
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/07/1994
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/22/1989
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
FLIGHT LEVEL 970609/13/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
LONG ISLAND ENGINEERING & ARCHITECT104/24/2026
ASR ENGINEERING PC104/10/2025
SYED ENGINEERING, P.C.103/27/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
JAM CONSULTANTS, INC.403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
BDS ELECTRIC CORP.Electrical103/22/2026
C PLUS DESIGN GROUP INCGeneral Contractor106/28/2026
WATERMARK PLUMBING CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SJS INSPECTIONS AND CONSU8286103/27/2025
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralPermit IssuedC PLUS DESIGN GROUP INC06/26/2026
DOB NOWPlumbingPermit IssuedWATERMARK PLUMBING CORP01/21/2026
▾Special Inspection Requirements (DOB NOW) — 13
DateRequirementInspectorRole
04/01/2026Mechanical Systems—special
04/01/2026Final—progress
03/24/2025Energy Code Compliance InspectionsSERGEY BOLOTOVprogress
03/24/2025Fire-Resistance Rated ConstructionSERGEY BOLOTOVprogress
03/24/2025FinalSERGEY BOLOTOVprogress
03/24/2025Fenestration air leakageSERGEY BOLOTOVenergy_progress
03/24/2025Fire-Resistant Penetrations and JointsSERGEY BOLOTOVspecial
03/24/2025Fenestration and door U-factor and product ratingsSERGEY BOLOTOVenergy_progress
03/24/2025Insulation placement and R valuesSERGEY BOLOTOVenergy_progress
03/24/2025Fenestration areasSERGEY BOLOTOVenergy_progress
03/24/2025Lighting controlsSERGEY BOLOTOVenergy_progress
03/24/2025Air barrier - visual inspectionSERGEY BOLOTOVenergy_progress
03/24/2025Structural Stability – Alterations of existing buildingsSERGEY BOLOTOVspecial
▾Documents — 12 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/20/2026Q01200111-I1Request digital key ↗
08/20/2026Q01200111-S2Request digital key ↗
08/20/2026Q01200111-S1Request digital key ↗
▸Seals & Professional Certifications6
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/20/2026Q01200111-S2Open ↗
08/13/2026Q01200111-I1Open ↗
08/13/2026Q01200111-S1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
09/01/2026Q01200111-I1Open ↗
09/01/2026Q01200111-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
09/01/2026Q01200111-I1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/20/2026Q01200111-S2Open ↗
08/13/2026Q01200111-I1Open ↗
08/13/2026Q01200111-S1Open ↗