← Back
Two family frame
101-60 105 STREET
QUEENS · BIN 4198440
💬 Discuss this project
1920Year Built
2.5Stories
B2Building Class
R4-1Zoning
1,780 sfGross Floor Area
2Units
0 Open ViolationsFDNY Report ↗
Two family frame · 2,500 sf lot · 0.71 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
INDETAIL ARCHITECTURAL AND ENGIN208/31/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
HTX BUILDING CONSULTING203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ALTECO CORPGeneral Contractor707/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
INDETAIL DESIGN ARCHITECT4828105/05/2021
Building Lifecycle
All (32)Filed (2)Permit Issued (3)Signed Off (1)Violation (2)Inspection (1)Objection (18)Special Inspection (5)
01/03/2022
Signed off — Alteration
REMOVED EXTG. ILLEGAL STORAGE LOCATED ON REAR YARD, REBUILD DOMESTIC STORAGE, ANSWER VIOLATION 35560127K. NO CHANGE IN USE, OCCUPANCY AND EGRESS.
Q00515913-I1
12/28/2021
Permit issued — Structural
Q00515913-I1-FO
12/28/2021
Permit issued — Structural
Q00515913-I1-ST
11/30/2021
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
10/20/2021
Permit issued — General Construction
Q00515913-I1-GC
08/31/2021
Filed — Alteration
REMOVED EXTG. ILLEGAL STORAGE LOCATED ON REAR YARD, REBUILD DOMESTIC STORAGE, ANSWER VIOLATION 35560127K. NO CHANGE IN USE, OCCUPANCY AND EGRESS.
Q00515913-P1
08/30/2021
Special inspection requirement — Masonry
08/30/2021
Special inspection requirement — Wood – Prefabricated I-Joists
08/30/2021
Special inspection requirement — Concrete - Cast-In-Place
08/30/2021
Special inspection requirement — Final
08/30/2021
Special inspection requirement — Footing and Foundation
08/13/2021
Objection resolved — Addressed
08/13/2021
Objection resolved — Addressed
08/13/2021
Objection resolved — Addressed
08/13/2021
Objection resolved — Addressed
08/13/2021
Objection resolved — Addressed
08/13/2021
Objection resolved — Addressed
08/13/2021
Objection resolved — Addressed
07/20/2021
Objection resolved — Addressed
06/23/2021
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/21/2021
Objection resolved — Addressed
06/07/2021
Objection raised — Other
06/07/2021
Objection raised — Zoning
06/07/2021
Objection raised — Zoning
06/07/2021
Objection raised — Zoning
06/07/2021
Objection raised — Zoning
06/07/2021
Objection raised — Inspections
06/07/2021
Objection raised — Scope
06/07/2021
Objection raised — Scope
06/07/2021
Objection raised — Inspections
05/05/2021
Filed — Alteration
REMOVED EXTG. ILLEGAL STORAGE LOCATED ON REAR YARD, REBUILD DOMESTIC STORAGE, ANSWER VIOLATION 35560127K. NO CHANGE IN USE, OCCUPANCY AND EGRESS.
Q00515913-I1
03/29/2021
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralPermit IssuedALTECO CORP12/28/2021
DOB NOWStructuralPermit IssuedALTECO CORP12/28/2021
DOB NOWGeneral ConstructionSigned-offALTECO CORP10/20/2021
Nothing on file for this building.
▾Field Inspections (DOB CAP) — 1
DateTypeResultReport
11/30/2021Pass-Final General Construction Non-Directive 14PassView ↗
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
08/30/2021Masonry—special
08/30/2021Wood – Prefabricated I-Joists—special
08/30/2021Concrete - Cast-In-Place—special
08/30/2021Final—progress
08/30/2021Footing and Foundation—progress
▾Documents — 4 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/27/2026Q00515913-P1Request digital key ↗
08/15/2026Q00515913-I1Request digital key ↗
▸Seals & Professional Certifications2
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/27/2026Q00515913-P1Open ↗
08/27/2026Q00515913-I1Open ↗