← Back
Primarily 2 family with 1 store or office
143-09 HILLSIDE AVENUE
QUEENS · BIN 4207298
💬 Discuss this project
1931
Year Built
3
Stories
S2
Building Class
C4-4D
Zoning
3,300 sf
Gross Floor Area
3
Units
Primarily 2 family with 1 store or office · 1,824 sf lot · 1.81 FAR built · Flood zone X
Floor Stack
3
People & Firms
2
Timeline
16
Permits & Filings
0
Scope of Work
0
Inspections
0
Documents
0
Locations of Work
Architecture
Mechanical
Plumbing
Roof
1p · 1 filing · 20 docs
Architecture
Project Q01202297 ↗
Signed-off · 04/25/2025
Repair front store wall Stucco and add a structural dunnage at the roof level to support exhaust equipment
On file for this project
22 documents · 1 drawing sheet
Floor 1
1p · 1 filing · 20 docs
Plumbing
Project Q01202297 ↗
Signed-off · 04/25/2025
Repair front store wall Stucco and add a structural dunnage at the roof level to support exhaust equipment
On file for this project
22 documents · 1 drawing sheet
Cellar
3p · 1 filing · 20 docs
Architecture
Mechanical
Project Q01202297 ↗
Signed-off · 04/25/2025
Repair front store wall Stucco and add a structural dunnage at the roof level to support exhaust equipment
On file for this project
22 documents · 3 drawing sheets
Design Consultants
1
Special Inspectors
1
▾
Design Consultants (Architect / Engineer of Record)
Firm
Filings
Most Recent
RAMIREZ ENGINEERING PLLC
4
08/13/2025
▾
Special Inspection Agencies
Agency
License #
Filings
Most Recent
RAMIREZ ENGINEERING PLLC
8679
3
04/10/2025
Building Lifecycle
All (16)
Filed (4)
Signed Off (2)
Special Inspection (10)
03/26/2026
Signed off — Alteration
INSTALL GAS ON EXISTING SERVICE FOR THE NEW KITCHEN EQUIPMENT AND WATER HEATER. ADD A KITCHEN SINK AND TWO WATER DRAINAGE AT KITCHEN.
Q01202297-I1
09/05/2025
Special inspection requirement — Tenant Protection Plan Compliance
Amauris Ramirez
08/13/2025
Filed — Alteration
INSTALL GAS ON EXISTING SERVICE FOR THE NEW KITCHEN EQUIPMENT AND WATER HEATER. ADD A KITCHEN SINK AND TWO WATER DRAINAGE AT KITCHEN.
Q01202297-P1
07/14/2025
Signed off — Alteration
INSTALL GAS ON EXISTING SERVICE FOR THE NEW KITCHEN EQUIPMENT AND WATER HEATER. ADD A KITCHEN SINK AND TWO WATER DRAINAGE AT KITCHEN.
Q01202297-S2
04/12/2025
Special inspection requirement — Energy Code Compliance Inspections
Amauris Ramirez
04/11/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Amauris Ramirez
04/10/2025
Filed — Alteration
INSTALL GAS ON EXISTING SERVICE FOR THE NEW KITCHEN EQUIPMENT AND WATER HEATER. ADD A KITCHEN SINK AND TWO WATER DRAINAGE AT KITCHEN.
Q01202297-S2
04/09/2025
Special inspection requirement — Final
Amauris Ramirez
04/09/2025
Special inspection requirement — Tenant Protection Plan Compliance
Amauris Ramirez
04/09/2025
Special inspection requirement — Structural Steel - Details
Amauris Ramirez
04/09/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Amauris Ramirez
04/08/2025
Filed — Alteration
INSTALL GAS ON EXISTING SERVICE FOR THE NEW KITCHEN EQUIPMENT AND WATER HEATER. ADD A KITCHEN SINK AND TWO WATER DRAINAGE AT KITCHEN.
Q01202297-S1
04/04/2025
Filed — Alteration
INSTALL GAS ON EXISTING SERVICE FOR THE NEW KITCHEN EQUIPMENT AND WATER HEATER. ADD A KITCHEN SINK AND TWO WATER DRAINAGE AT KITCHEN.
Q01202297-I1
04/03/2025
Special inspection requirement — Tenant Protection Plan Compliance
Amauris Ramirez
03/27/2025
Special inspection requirement — Mechanical Systems
Amauris Ramirez
03/27/2025
Special inspection requirement — Final
Amauris Ramirez
Nothing on file for this building.
Nothing on file for this building.
Nothing on file for this building.
Nothing on file for this building.