← Back
One story retail building
90-41 160 STREET
QUEENS · BIN 4208843
💬 Discuss this project
1931Year Built
1Stories
K1Building Class
C6-3Zoning
1,200 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
One story retail building · Owner of record: 9041 LLC · 1,386 sf lot · 0.87 FAR built · Flood zone X
Locations of Work
Architecture
Floor 12p · 1 filing · 10 docs
Nothing on file for this building.
Building Lifecycle
All (24)Filed (2)Permit Issued (2)Signed Off (1)Violation (4)Inspection (1)Objection (10)Special Inspection (4)
02/17/2026
Signed off — Alteration
MINOR INTERIOR RENOVATIONS OF EXISTING NAIL SALON AT 1ST FLOOR. NO CHANGE TO EXISTING USE, OCCUPANCY OR EGRESS.
Q01192917-I1
02/13/2026
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
02/12/2026
Violation issued (FDNY_NOV, closed)
01/27/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
DEZHANG FANG
01/27/2026
Special inspection requirement — Fire-Resistance Rated Construction
DEZHANG FANG
01/14/2026
Objection resolved — Addressed
01/14/2026
Objection resolved — Addressed
01/05/2026
Objection raised — Structural
01/05/2026
Objection raised — Structural
12/19/2025
Filed — Alteration
MINOR INTERIOR RENOVATIONS OF EXISTING NAIL SALON AT 1ST FLOOR. NO CHANGE TO EXISTING USE, OCCUPANCY OR EGRESS.
Q01192917-P1
12/16/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
DEZHANG FANG
12/16/2025
Special inspection requirement — Fire-Resistance Rated Construction
DEZHANG FANG
12/12/2025
Permit issued — General Construction
Q01192917-I1-GC
04/11/2025
Permit issued — General Construction
Q01192917-I1-GC
03/26/2025
Objection resolved — Addressed
03/26/2025
Objection resolved — Addressed
03/26/2025
Objection resolved — Addressed
03/24/2025
Objection raised — Structural
03/24/2025
Objection raised — Cost
03/24/2025
Objection raised — Mechanical
03/13/2025
Filed — Alteration
MINOR INTERIOR RENOVATIONS OF EXISTING NAIL SALON AT 1ST FLOOR. NO CHANGE TO EXISTING USE, OCCUPANCY OR EGRESS.
Q01192917-I1
03/21/2018
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/13/2018
Violation issued (ECB, closed)
Construction
12/27/2017
Violation issued (ECB, closed)
Construction
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
NEW SCHOOL PROSTHETICS ORTHOTI203/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
FANG ARCHITECT212/19/2025
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
DUVAL LLCGeneral Contractor204/09/2026
TREVOR DUNWELLElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
FANG ARCHITECT5513212/19/2025
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offDUVAL LLC12/12/2025
DOB NOWGeneral ConstructionSigned-offDUVAL LLC04/11/2025
BISOTISSUEDICM GLOBAL DESIGN INC03/15/2018
BISOTISSUEDHANSOL SIGN ART CORP03/01/2007
BISFPISSUEDIDEAL FIRE SYSTEMS, INC08/21/2002
BISFPISSUEDNEW YORK BUSINESS FIRE SYSTEM02/27/2001
BISOTISSUEDACE SIGN AND RIGGING CORP06/09/1994
▾Field Inspections (DOB CAP) — 1
DateTypeResultReport
02/13/2026Pass-Final General Construction Non-Directive 14PassView ↗
▾Special Inspection Requirements (DOB NOW) — 4
DateRequirementInspectorRole
01/27/2026Fire-Resistant Penetrations and JointsDEZHANG FANGspecial
01/27/2026Fire-Resistance Rated ConstructionDEZHANG FANGprogress
12/16/2025Fire-Resistant Penetrations and JointsDEZHANG FANGspecial
12/16/2025Fire-Resistance Rated ConstructionDEZHANG FANGprogress
▾Documents — 34 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/20/2026Q01192917-P1Contact architect ↗
08/20/2026Q01192917-I1Contact architect ↗
▸Applications & Permits5
▸BISWORK PERMIT APPLICATION2
03/19/2018421611116Open ↗
11/21/2008410187630Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION2
03/23/2018421611116Open ↗
11/05/2008410187630Open ↗
▸BISNon-Directive 14 Construction Sign Off Including Sign Applications1
06/05/2018421611116Open ↗
▸Seals & Professional Certifications9
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION3
06/05/2018421611116Open ↗
03/23/2018421611116Open ↗
03/19/2018421611116Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/20/2026Q01192917-P1Open ↗
08/20/2026Q01192917-I1Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
03/23/2018421611116Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
03/23/2018421611116Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
08/26/2026Q01192917-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/26/2026Q01192917-I1Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/20/2026Q01192917-I1Open ↗
08/20/2026Q01192917-P1Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
03/23/2018421611116Open ↗
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER1
11/05/2008410187630Open ↗
▸Energy Compliance4
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS3
06/05/2018421611116Open ↗
03/23/2018421611116Open ↗
03/19/2018421611116Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
06/05/2018421611116Open ↗
▸Approvals, Objections & Sign-offs2
▸BISADMINISTRATIVE OBJECTIONS1
11/05/2008410187630Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
06/05/2018421611116Open ↗
▸Cost, Insurance & Ownership3
▸BISCOST AFFIDAVIT3
06/05/2018421611116Open ↗
03/23/2018421611116Open ↗
11/05/2008410187630Open ↗
▸Filing & Intake Forms3
▸BISEFILING COVER SHEET2
03/23/2018421611116Open ↗
11/05/2008410187630Open ↗
▸BISADDITIONAL INFORMATION1
03/23/2018421611116Open ↗
▸Other Documents2
▸DOB NOWWaiver Document2
08/13/2026Q01192917-P1Open ↗
08/13/2026Q01192917-I1Open ↗