← Back
Two stories - detached, small or mid-size
85-42 CHEVY CHASE STREET
QUEENS · BIN 4213546
💬 Discuss this project
1935Year Built
2Stories
A1Building Class
R1-2Zoning
1,824 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
Two stories - detached, small or mid-size · 7,790 sf lot · 0.23 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralPlumbing
Roof2p · 1 filing · 20 docs
Floor 24p · 2 filings · 20 docs
Floor 1
Cellar8p · 2 filings · 20 docs
2 jobs · most recent 05/03/2024
General Wiring
FiledStatusContractorScope
05/03/2024CompleteINDY ELECTRIC CORP.General Wiring
12/30/2021CompleteMLS ELECTRIC LLCGeneral Wiring
Building Lifecycle
All (77)Filed (9)Permit Issued (12)Signed Off (3)Violation (5)Inspection (6)Objection (12)Special Inspection (30)
09/04/2024
Signed off — Alteration
APPLICATION FILED FOR GUT REHAB EXISTING ONE FAMILY DWELLING, NEW FRONT ENTRANCE ADDITION OF 18 SQ. FT. AND A VERTICAL ENLARGE AT REAR 2ND.FL. 346 sfOVER EXISTING FIRST FLOOR.
Q00653968-I1
09/03/2024
Permit issued — Mechanical Systems
Q00653968-I1-MS
08/30/2024
Signed off — Alteration
temp construction fence; scaffolding
Q00767059-I1
07/26/2024
Signed off — Alteration
minor plumbing work at cellar, 001,002
Q00653277-I1
06/26/2024
Violation issued (ECB, closed)
Zoning
05/03/2024
Filed — Alteration
minor plumbing work at cellar, 001,002
Q00653277-P2
05/03/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
SYED RIZVI
05/03/2024
Special inspection requirement — Energy Code Compliance Inspections
SYED RIZVI
05/01/2024
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
05/01/2024
Special inspection requirement — Energy Code Compliance Inspections
SYED RIZVI
05/01/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
SYED RIZVI
04/29/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
04/25/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
09/11/2023
Permit issued — Construction Fence
Q00767059-I1-FN
09/08/2023
Permit issued — Supported Scaffold
Q00767059-I1-SF
08/29/2023
Permit issued — Construction Fence
Q00767059-I1-SF
08/25/2023
Permit issued — Construction Fence
Q00767059-I1-FN
08/16/2023
Permit issued — Structural
Q00653968-I1-GC-CX
07/24/2023
Special inspection requirement — Mechanical Systems
SYED RIZVI
07/24/2023
Special inspection requirement — Structural Steel - High Strength Bolting
SYED RIZVI
07/24/2023
Special inspection requirement — Final
HAYM GROSS
07/24/2023
Special inspection requirement — Fire-Resistance Rated Construction
SYED RIZVI
07/24/2023
Special inspection requirement — Structural Wood Frame
SYED RIZVI
07/24/2023
Special inspection requirement — Energy Code Compliance Inspections
SYED RIZVI
07/24/2023
Special inspection requirement — Fenestration air leakage
SYED RIZVI
07/24/2023
Special inspection requirement — Air barrier - visual inspection
SYED RIZVI
07/24/2023
Special inspection requirement — Interior lighting power
SYED RIZVI
07/24/2023
Special inspection requirement — Fenestration and door U-factor and product ratings
SYED RIZVI
07/24/2023
Special inspection requirement — Fenestration areas
SYED RIZVI
07/24/2023
Special inspection requirement — Lighting in dwelling units
SYED RIZVI
07/24/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
SYED RIZVI
07/24/2023
Special inspection requirement — Structural Steel - Welding
SYED RIZVI
07/24/2023
Special inspection requirement — Concrete - Cast-In-Place
SYED RIZVI
07/24/2023
Special inspection requirement — Masonry
SYED RIZVI
07/21/2023
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
07/21/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
07/21/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
07/06/2023
Permit issued — Plumbing
Q00653277-I1-PL
06/30/2023
Filed — Alteration
minor plumbing work at cellar, 001,002
Q00653277-P1
05/24/2023
Special inspection requirement — Energy Code Compliance Inspections
SYED RIZVI
05/24/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
SYED RIZVI
04/07/2023
Filed — Alteration
APPLICATION FILED FOR GUT REHAB EXISTING ONE FAMILY DWELLING, NEW FRONT ENTRANCE ADDITION OF 18 SQ. FT. AND A VERTICAL ENLARGE AT REAR 2ND.FL. 346 sfOVER EXISTING FIRST FLOOR.
Q00653968-P2
03/27/2023
Special inspection requirement — Air barrier - visual inspection
SYED RIZVI
03/27/2023
Special inspection requirement — Concrete - Cast-In-Place
SYED RIZVI
03/27/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
SYED RIZVI
03/27/2023
Special inspection requirement — Masonry
SYED RIZVI
03/27/2023
Special inspection requirement — Mechanical Systems
SYED RIZVI
03/27/2023
Special inspection requirement — Structural Steel - High Strength Bolting
SYED RIZVI
03/27/2023
Special inspection requirement — Structural Steel - Welding
SYED RIZVI
03/27/2023
Special inspection requirement — Energy Code Compliance Inspections
SYED RIZVI
03/16/2023
Permit issued — Plumbing
Q00653277-I1-PL
07/01/2022
Permit issued — Supported Scaffold
Q00767059-I1-SF
07/01/2022
Permit issued — Supported Scaffold
Q00767059-I1-FN
06/29/2022
Filed — Alteration
temp construction fence; scaffolding
Q00767059-I1
06/29/2022
Violation issued (ECB, closed)
Construction
06/29/2022
Violation issued (ECB, closed)
Construction
06/17/2022
Permit issued — Mechanical Systems
Q00653968-I1-GC-CX
05/10/2022
Violation issued (ECB, closed)
Construction
04/14/2022
Filed — Alteration
APPLICATION FILED FOR GUT REHAB EXISTING ONE FAMILY DWELLING, NEW FRONT ENTRANCE ADDITION OF 18 SQ. FT. AND A VERTICAL ENLARGE AT REAR 2ND.FL. 346 sfOVER EXISTING FIRST FLOOR.
Q00653968-P1
02/02/2022
Objection raised — Scope
Latest 60 of 77 events.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
FOAM INC MAGIC203/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
05/03/2023$1.3M—Private party → Private party$724/sf building
09/12/2017$969K—Private party → Private party$531/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
HAYM S. GROSS, ARCHITECT405/03/2024
RIKE TECH ASSOCIATES LLC304/07/2023
HC ARCHITECT, PC206/01/2018
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
BRITZ ENTERPRISES INC.1403/21/2026
A D BUILDING SOLUTIONS403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
BEST MATCH CORPORATIONGeneral Contractor1407/08/2026
MAGIC FOAM INCGeneral Contractor903/21/2026
ALL PRO PLBG & HTG INCPlumbing207/08/2026
ROCK E SMALL PLBG&HTG INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
RIKE TECH ASSOCIATES LLC2965705/03/2024
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offBEST MATCH CORPORATION09/03/2024
DOB NOWConstruction FenceSigned-offBEST MATCH CORPORATION09/11/2023
DOB NOWSupported ScaffoldSigned-offBEST MATCH CORPORATION09/08/2023
DOB NOWConstruction FenceSigned-offBEST MATCH CORPORATION08/29/2023
DOB NOWConstruction FenceSigned-offBEST MATCH CORPORATION08/25/2023
DOB NOWStructuralSigned-offBEST MATCH CORPORATION08/16/2023
DOB NOWPlumbingSigned-offROCK E SMALL PLBG&HTG INC07/06/2023
DOB NOWPlumbingSigned-offALL PRO PLBG & HTG INC03/16/2023
DOB NOWSupported ScaffoldSigned-offMAGIC FOAM INC07/01/2022
DOB NOWSupported ScaffoldSigned-offMAGIC FOAM INC07/01/2022
DOB NOWMechanical SystemsSigned-offMAGIC FOAM INC06/17/2022
DOB NOWPlumbingSigned-offALL PRO PLBG & HTG INC02/01/2022
▾Field Inspections (DOB CAP) — 6
DateTypeResultReport
05/01/2024Pass-Final General Construction Non-Directive 14PassView ↗
04/29/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
04/25/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
07/21/2023Certified Gas-Gas-Piping-RoughingCertifiedView ↗
07/21/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
07/21/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 55
DateRequirementInspectorRole
05/03/2024Fire-Resistant Penetrations and JointsSYED RIZVIspecial
05/03/2024Energy Code Compliance InspectionsSYED RIZVIprogress
05/01/2024Energy Code Compliance InspectionsSYED RIZVIprogress
05/01/2024Fire-Resistant Penetrations and JointsSYED RIZVIspecial
07/24/2023Mechanical SystemsSYED RIZVIspecial
07/24/2023Structural Steel - High Strength BoltingSYED RIZVIspecial
07/24/2023FinalHAYM GROSSprogress
07/24/2023Fire-Resistance Rated ConstructionSYED RIZVIprogress
07/24/2023Structural Wood FrameSYED RIZVIprogress
07/24/2023Energy Code Compliance InspectionsSYED RIZVIprogress
07/24/2023Fenestration air leakageSYED RIZVIenergy_progress
07/24/2023Air barrier - visual inspectionSYED RIZVIenergy_progress
07/24/2023Interior lighting powerSYED RIZVIenergy_progress
07/24/2023Fenestration and door U-factor and product ratingsSYED RIZVIenergy_progress
07/24/2023Fenestration areasSYED RIZVIenergy_progress
07/24/2023Lighting in dwelling unitsSYED RIZVIenergy_progress
07/24/2023Fire-Resistant Penetrations and JointsSYED RIZVIspecial
07/24/2023Structural Steel - WeldingSYED RIZVIspecial
07/24/2023Concrete - Cast-In-PlaceSYED RIZVIspecial
07/24/2023MasonrySYED RIZVIspecial
05/24/2023Energy Code Compliance InspectionsSYED RIZVIprogress
05/24/2023Fire-Resistant Penetrations and JointsSYED RIZVIspecial
03/27/2023Air barrier - visual inspectionSYED RIZVIenergy_progress
03/27/2023Concrete - Cast-In-PlaceSYED RIZVIspecial
03/27/2023Fire-Resistant Penetrations and JointsSYED RIZVIspecial
Latest 25 of 55.
▾Documents — 66 on file (BIS + DOB NOW)
▸Plans & Drawings9
▸DOB NOWPlans/Sketch9
08/29/2026Q00049279-I1Request digital key ↗
08/29/2026Q00049348-I1Request digital key ↗
08/26/2026Q00653968-P1Request digital key ↗
Showing 3 of 9 on file for this type
▸Applications & Permits2
▸BISPLAN / WORK APPROVAL APPLICATION2
06/19/2018421583708Open ↗
06/13/2018421641824Open ↗
▸Zoning, Tax Lot & Property Records3
▸DOB NOWZD1: DOB Zoning Diagram3
08/13/2026Q00653968-P2Open ↗
08/13/2026Q00653968-I1Open ↗
08/13/2026Q00653968-P1Open ↗
▸Seals & Professional Certifications28
▸DOB NOWProgress Inspector Seal & Signature11
09/01/2026Q00653968-P1Open ↗
09/01/2026Q00653968-P1Open ↗
09/01/2026Q00653968-P2Open ↗
Showing 3 of 11 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature9
08/29/2026Q00049279-I1Open ↗
08/26/2026Q00767059-I1Open ↗
08/22/2026Q00653277-P2Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature7
09/01/2026Q00653968-P1Open ↗
09/01/2026Q00653968-P2Open ↗
08/29/2026Q00653277-I1Open ↗
Showing 3 of 7 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
12/19/2017421583708Open ↗
▸Trade Schedules & Equipment1
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE1
12/19/2017421583708Open ↗
▸Environmental & Asbestos6
▸DOB NOWDEP ACP-5: Asbestos Assessment Report6
08/22/2026Q00653277-I1Open ↗
08/22/2026Q00653277-P2Open ↗
08/22/2026Q00653277-P1Open ↗
Showing 3 of 6 on file for this type
▸Energy Compliance2
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
12/19/2017421583708Open ↗
▸DOB NOWEN2: As Built Energy Analysis1
08/13/2026Q00653968-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸BISSCHEDULE A - OCCUPANCY / USE1
06/19/2018421583708Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
12/19/2017421583708Open ↗
▸Filing & Intake Forms3
▸BISEFILING COVER SHEET2
06/13/2018421641824Open ↗
12/19/2017421583708Open ↗
▸BISBPP: CHECKLIST IN LIEU OF PLANS-ALT31
06/13/2018421641824Open ↗
▸Other Documents10
▸DOB NOWPlot Diagram3
08/13/2026Q00653968-P2Open ↗
08/13/2026Q00653968-P1Open ↗
08/13/2026Q00653968-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone3
08/13/2026Q00653968-I1Open ↗
08/13/2026Q00653968-P1Open ↗
08/13/2026Q00653968-P2Open ↗
▸DOB NOWSite Survey: Initial2
08/13/2026Q00653968-I1Open ↗
08/13/2026Q00653968-P2Open ↗
▸BISBPP - DOT Builders Pavement Unit Waiver Request Form1
06/13/2018421641824Open ↗
▸BISPLOT DIAGRAM1
12/19/2017421583708Open ↗