Primarily 2 family with 1 store or office
137-38 JAMAICA AVENUE
QUEENS · BIN 4213658
💬 Discuss this project
1920Year Built
2Stories
S2Building Class
R7AZoning
1,500 sfGross Floor Area
3Units
Primarily 2 family with 1 store or office · 1,261 sf lot · 1.19 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Floor 11p · 1 filing · 13 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
GRUPO DESIGN207/29/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
SIMPLE ARCHITECTURE PC203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
MKSSKR CONSULTING SERVICEGeneral Contractor407/08/2026
SIGNORE & SONS PLBG CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
GIOVANNI ZAPATA R.A.3882207/29/2022
Building Lifecycle
All (16)Filed (2)Permit Issued (3)Inspection (4)Special Inspection (7)
10/10/2023
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
07/12/2023
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
01/02/2023
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
10/24/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
10/06/2022
Permit issued — Plumbing
Q00719806-S1-PL
08/15/2022
Permit issued — General Construction
Q00719806-I1-GC
08/15/2022
Permit issued — General Construction
Q00719806-I1-GC-CX
07/29/2022
Filed — Alteration
SUBSEQUENT PLUMBING FILING IN CONJUNCTION WITH GC WORK FILED AND APPROVED UNDER JOB # Q00719806-I1, FOR RETAIL STORE AT 1ST FLOOR.
Q00719806-S1
07/23/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
GIOVANNI ZAPATA
05/10/2022
Filed — Alteration
SUBSEQUENT PLUMBING FILING IN CONJUNCTION WITH GC WORK FILED AND APPROVED UNDER JOB # Q00719806-I1, FOR RETAIL STORE AT 1ST FLOOR.
Q00719806-I1
04/29/2022
Special inspection requirement — Electrical motors and elevators
RONALD VILLANO
04/29/2022
Special inspection requirement — Lighting in dwelling units
RONALD VILLANO
04/15/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
GIOVANNI ZAPATA
04/15/2022
Special inspection requirement — Final
GIOVANNI ZAPATA
04/15/2022
Special inspection requirement — Mechanical Systems
GIOVANNI ZAPATA
04/15/2022
Special inspection requirement — Energy Code Compliance Inspections
GIOVANNI ZAPATA
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedSIGNORE & SONS PLBG CORP10/06/2022
DOB NOWGeneral ConstructionPermit IssuedMKSSKR CONSULTING SERVICE08/15/2022
DOB NOWGeneral ConstructionPermit IssuedMKSSKR CONSULTING SERVICE08/15/2022
1 project · most recent 03/04/2022
General Wiring
FiledStatusContractorScope
03/04/2022Permit IssuedPOWER SURGE ELECTRIC, INCGeneral Wiring
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
10/10/2023Pass-Final CND-Occupancy InspectionPassView ↗
07/12/2023Pass-Final CND-Occupancy InspectionPassView ↗
01/02/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
10/24/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 7
DateRequirementInspectorRole
07/23/2022Fire-Resistant Penetrations and JointsGIOVANNI ZAPATAspecial
04/29/2022Electrical motors and elevatorsRONALD VILLANOenergy_progress
04/29/2022Lighting in dwelling unitsRONALD VILLANOenergy_progress
04/15/2022Fire-Resistant Penetrations and JointsGIOVANNI ZAPATAspecial
04/15/2022FinalGIOVANNI ZAPATAprogress
04/15/2022Mechanical SystemsGIOVANNI ZAPATAspecial
04/15/2022Energy Code Compliance InspectionsGIOVANNI ZAPATAprogress
▾Documents — 13 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/26/2026Q00719806-S1Request digital key ↗
08/26/2026Q00719806-I1Request digital key ↗
▸Seals & Professional Certifications9
▸DOB NOWProgress Inspector Seal & Signature4
08/31/2026Q00719806-I1Open ↗
08/31/2026Q00719806-I1Open ↗
08/31/2026Q00719806-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature3
08/31/2026Q00719806-S1Open ↗
08/31/2026Q00719806-I1Open ↗
08/31/2026Q00719806-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/26/2026Q00719806-S1Open ↗
08/26/2026Q00719806-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/26/2026Q00719806-I1Open ↗
08/26/2026Q00719806-S1Open ↗