← Back
Two stories - detached, small or mid-size
138-61 102 AVENUE
QUEENS · BIN 4214359
💬 Discuss this project
1925Year Built
2.5Stories
A1Building Class
R4Zoning
1,248 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
Two stories - detached, small or mid-size · 2,400 sf lot · 0.52 FAR built · Flood zone X
Locations of Work
Architecture
Permit Issued — active, not yet Signed-off
Floor 2Under Construction7p · 1 filing · 20 docs
Floor 1Under Construction6p · 1 filing · 20 docs
CellarUnder Construction5p · 1 filing · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
06/09/2015$425K—— → —$341/sf building
01/17/2014$413K—— → —$331/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
GERALD CALIENDO ARCHITECTS308/18/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
RAJINDRAH RAMRATTANElectrical103/21/2026
IMPACT BUILDERS CORPGeneral Contractor109/03/2026
RECORD GROUP INCGeneral Contractor107/30/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
AA BUILDING & INSPECTION1519108/05/2025
Building Lifecycle
All (54)Filed (3)Permit Issued (2)Violation (1)Objection (18)Special Inspection (30)
09/02/2026
Permit issued — Construction Fence
Q01264617-S2-FN
08/18/2026
Filed — Alteration CO
HEREWITH FILING ALTERATION TYPE ONE IN ORDER TO DO HORIZONTAL AND VERTICAL ENLARGEMENT TO AN EXISTING ONE FAMILY DWELLING AND CONVERT TO A TWO FAMILY DWELLING. TO ERECT INTERIOR PARTITIONS AND OBTAIN NEW CERTIFICATE OF OCCUPANCY.
Q01264617-S2
08/18/2026
Objection resolved — Resolved
08/18/2026
Objection resolved — Resolved
08/14/2026
Special inspection requirement — HVAC-R and service water heating equipment
08/14/2026
Special inspection requirement — HVAC-R and service water heating system controls
08/14/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
08/14/2026
Special inspection requirement — Maintenance information
08/10/2026
Objection raised — Inspections
08/10/2026
Objection raised — Energy
07/29/2026
Permit issued — General Construction
Q01264617-I1-GC-CX
07/27/2026
Filed — Alteration CO
HEREWITH FILING ALTERATION TYPE ONE IN ORDER TO DO HORIZONTAL AND VERTICAL ENLARGEMENT TO AN EXISTING ONE FAMILY DWELLING AND CONVERT TO A TWO FAMILY DWELLING. TO ERECT INTERIOR PARTITIONS AND OBTAIN NEW CERTIFICATE OF OCCUPANCY.
Q01264617-S1
07/27/2026
Special inspection requirement — Energy Code Compliance Inspections
07/27/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
03/17/2026
Objection resolved — Addressed
03/17/2026
Objection resolved — Addressed
01/26/2026
Special inspection requirement — Ventilation and air distribution system
Younes Abouyaala
01/22/2026
Objection resolved — Addressed
01/22/2026
Objection resolved — Addressed
01/22/2026
Objection resolved — Addressed
01/22/2026
Objection resolved — Addressed
01/22/2026
Objection resolved — Addressed
12/17/2025
Special inspection requirement — Metering
Younes Abouyaala
12/17/2025
Special inspection requirement — Electric vehicle service equipment requirements
Younes Abouyaala
09/10/2025
Violation issued (ECB, closed)
Construction
08/20/2025
Objection raised — Zoning
08/20/2025
Objection raised — Cost
08/20/2025
Objection raised — Zoning
08/20/2025
Objection raised — Zoning
08/20/2025
Objection raised — Zoning
08/20/2025
Objection raised — Zoning
08/19/2025
Objection raised — Admin
08/05/2025
Filed — Alteration CO
HEREWITH FILING ALTERATION TYPE ONE IN ORDER TO DO HORIZONTAL AND VERTICAL ENLARGEMENT TO AN EXISTING ONE FAMILY DWELLING AND CONVERT TO A TWO FAMILY DWELLING. TO ERECT INTERIOR PARTITIONS AND OBTAIN NEW CERTIFICATE OF OCCUPANCY.
Q01264617-I1
08/01/2025
Special inspection requirement — Exterior Insulation and Finish Systems (EIFS)
Younes Abouyaala
08/01/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
Younes Abouyaala
08/01/2025
Special inspection requirement — Subgrade Inspections
Younes Abouyaala
08/01/2025
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
SHAHRIAR QUAYYUM
08/01/2025
Special inspection requirement — Fenestration air leakage
Younes Abouyaala
08/01/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Younes Abouyaala
08/01/2025
Special inspection requirement — Energy Code Compliance Inspections
Younes Abouyaala
08/01/2025
Special inspection requirement — Fire-Resistance Rated Construction
Younes Abouyaala
08/01/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
Younes Abouyaala
08/01/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
Younes Abouyaala
08/01/2025
Special inspection requirement — Concrete - Cast-In-Place
Younes Abouyaala
08/01/2025
Special inspection requirement — Permanent certificate
Younes Abouyaala
08/01/2025
Special inspection requirement — Fenestration areas
Younes Abouyaala
08/01/2025
Special inspection requirement — Insulation placement and R values
Younes Abouyaala
08/01/2025
Special inspection requirement — Air barrier — testing
Younes Abouyaala
08/01/2025
Special inspection requirement — Protection of exposed foundation insulation
Younes Abouyaala
08/01/2025
Special inspection requirement — HVAC-R and service water heating equipment
Younes Abouyaala
08/01/2025
Special inspection requirement — Interior lighting power
Younes Abouyaala
08/01/2025
Special inspection requirement — HVAC-R and service water heating system controls
Younes Abouyaala
08/01/2025
Special inspection requirement — Air barrier - visual inspection
Younes Abouyaala
08/01/2025
Special inspection requirement — Maintenance information
Younes Abouyaala
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWConstruction FencePermit IssuedIMPACT BUILDERS CORP09/02/2026
DOB NOWGeneral ConstructionPermit IssuedRECORD GROUP INC07/29/2026
1 project · most recent 08/18/2026
Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
08/18/2026Permit IssuedIMPACT BUILDERS CORPVentilation Systems
Ventilation
Mitsubishi Electric M4H36W06060615-B 38,000 BTU ×1
1 project · most recent 08/18/2026
Storm Water/Sanitary
FiledStatusContractorScope
08/18/2026——Storm, Water/Sanitary
1 project · most recent 07/28/2026
General Wiring
FiledStatusContractorScope
07/28/2026Permit IssuedVILLAGE ELECTL CONTRS INCGeneral Wiring
1 project · most recent 08/18/2026
Fence
FiledStatusContractorScope
08/18/2026Permit IssuedIMPACT BUILDERS CORPFence
▾Special Inspection Requirements (DOB NOW) — 32
DateRequirementInspectorRole
08/14/2026HVAC-R and service water heating equipment—energy_progress
08/14/2026HVAC-R and service water heating system controls—energy_progress
08/14/2026HVAC-R and service water piping design and insulation—energy_progress
08/14/2026Maintenance information—energy_progress
07/27/2026Energy Code Compliance Inspections—progress
07/27/2026Fire-Resistant Penetrations and Joints—special
01/26/2026Ventilation and air distribution systemYounes Abouyaalaenergy_progress
12/17/2025MeteringYounes Abouyaalaenergy_progress
12/17/2025Electric vehicle service equipment requirementsYounes Abouyaalaenergy_progress
08/01/2025Exterior Insulation and Finish Systems (EIFS)Younes Abouyaalaspecial
08/01/2025Structural Stability – Alterations of existing buildingsYounes Abouyaalaspecial
08/01/2025Subgrade InspectionsYounes Abouyaalaspecial
08/01/2025Subsurface Investigations (Borings/Test Pits)SHAHRIAR QUAYYUMspecial
08/01/2025Fenestration air leakageYounes Abouyaalaenergy_progress
08/01/2025Fire-Resistant Penetrations and JointsYounes Abouyaalaspecial
08/01/2025Energy Code Compliance InspectionsYounes Abouyaalaprogress
08/01/2025Fire-Resistance Rated ConstructionYounes Abouyaalaprogress
08/01/2025Fenestration and door U-factor and product ratingsYounes Abouyaalaenergy_progress
08/01/2025HVAC-R and service water piping design and insulationYounes Abouyaalaenergy_progress
08/01/2025Concrete - Cast-In-PlaceYounes Abouyaalaspecial
08/01/2025Permanent certificateYounes Abouyaalaenergy_progress
08/01/2025Fenestration areasYounes Abouyaalaenergy_progress
08/01/2025Insulation placement and R valuesYounes Abouyaalaenergy_progress
08/01/2025Air barrier — testing Younes Abouyaalaenergy_progress
08/01/2025Protection of exposed foundation insulationYounes Abouyaalaenergy_progress
Latest 25 of 32.
▾Documents — 23 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/19/2026Q01264617-S2Request digital key ↗
08/19/2026Q01264617-I1Request digital key ↗
08/19/2026Q01264617-S1Request digital key ↗
▸Zoning, Tax Lot & Property Records2
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026Q01264617-I1Open ↗
▸DOB NOWZD1: DOB Zoning Diagram1
08/13/2026Q01264617-I1Open ↗
▸Seals & Professional Certifications9
▸DOB NOWSpecial Inspector Seal & Signature3
08/25/2026Q01264617-I1Open ↗
08/25/2026Q01264617-I1Open ↗
08/25/2026Q01264617-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature3
08/25/2026Q01264617-I1Open ↗
08/25/2026Q01264617-I1Open ↗
08/25/2026Q01264617-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/19/2026Q01264617-S2Open ↗
08/19/2026Q01264617-S1Open ↗
08/19/2026Q01264617-I1Open ↗
▸Safety & Tenant Protection1
▸DOB NOWStreet Tree Checklist1
08/13/2026Q01264617-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/19/2026Q01264617-I1Open ↗
08/15/2026Q01264617-S1Open ↗
▸Inspections & Test Reports2
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026Q01264617-I1Open ↗
▸DOB NOWSOIL REPORT1
08/13/2026Q01264617-I1Open ↗
▸Other Documents4
▸DOB NOWSite Survey: Initial1
08/13/2026Q01264617-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/13/2026Q01264617-I1Open ↗
▸DOB NOWPlot Diagram1
08/13/2026Q01264617-I1Open ↗
▸DOB NOWProperty Ownership Certification1
08/19/2026Q01264617-I1Open ↗