← Back
Two stories - detached, small or mid-size
110-03 164 PLACE
QUEENS · BIN 4216969
💬 Discuss this project
1925Year Built
2Stories
A1Building Class
R3AZoning
784 sfGross Floor Area
1Units
1 Open Violation 0 unresolved · 1 paperwork only ▸FDNY Report ↗
Two stories - detached, small or mid-size · 2,550 sf lot · 0.31 FAR built · Flood zone X
Locations of Work
StructuralPlumbing
Permit Issued — active, not yet Signed-off
Floor 2Under Construction6p · 1 filing · 17 docs
Floor 1Under Construction6p · 1 filing · 17 docs
CellarUnder Construction7p · 1 filing · 17 docs
1 job · most recent 04/03/2026
Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
04/03/2026Permit IssuedPRECISION HOME DEV INCAir Conditioning Systems, Ventilation Systems
Cooling
Fujitsu ASU7RLF1 7,000 BTU · Fan Coil Indoor ×8
Ventilation
Greenheck SP-C50-QD 50 CFM · Exhaust Fan ×5
SP-B90 100 CFM · Exhaust Fan ×2
1 job · most recent 04/03/2026
Gas Storm Water/Sanitary
FiledStatusContractorScope
04/03/2026Permit IssuedROCK E SMALL PLBG&HTG INCGas, Storm, Water/Sanitary
1 job · most recent 09/09/2026
General Wiring Lighting
FiledStatusContractorScope
09/09/2026Pending PaymentBDS ELECTRIC CORP.General Wiring, Lighting
1 job · most recent 04/03/2026
Wood
FiledStatusContractorScope
04/03/2026Permit IssuedROCK E SMALL PLBG&HTG INCWood
1 job · most recent 03/12/2026
Fence
FiledStatusContractorScope
03/12/2026Permit IssuedPRECISION HOME DEV INCFence
Building Lifecycle
All (23)Filed (3)Permit Issued (3)Violation (2)Inspection (1)Objection (11)Special Inspection (3)
08/12/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
07/27/2026
Permit issued — Plumbing
Q01368996-S1-PL
07/21/2026
Permit issued — Structural
Q01368996-I1-GC-CX
07/20/2026
Permit issued — Construction Fence
Q01368997-I1-FN
04/13/2026
Objection raised — Cost
04/13/2026
Objection raised — Other
04/03/2026
Filed — Alteration CO
Addition and alteration of an existing one-family house to convert it into a two-family house, as per drawings herewith filed, and obtain a certificate of occupancy.
Q01368996-S1
04/03/2026
Objection resolved — Addressed
04/03/2026
Objection resolved — Addressed
04/03/2026
Objection resolved — Addressed
04/03/2026
Objection resolved — Addressed
04/02/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
MUZAFFAR JAMAL
04/02/2026
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
MUZAFFAR JAMAL
04/02/2026
Special inspection requirement — Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention Facilities
Rajasekhar Sakhamuri
03/25/2026
Objection raised — Zoning
03/25/2026
Objection raised — Zoning
03/25/2026
Objection raised — Code
03/25/2026
Objection raised — Zoning
03/25/2026
Objection raised — Plumbing
03/13/2026
Filed — Alteration CO
Addition and alteration of an existing one-family house to convert it into a two-family house, as per drawings herewith filed, and obtain a certificate of occupancy.
Q01368996-I1
03/12/2026
Filed — Alteration
Install new construction fence as per drawing.
Q01368997-I1
05/16/2016
Violation issued (ECB, open)
Zoning
06/04/2005
Violation issued (ECB, closed)
Zoning
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
WORKFORCE CONTRACTING708/26/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ARCHITECTURAL CONCEPT304/03/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
ARCHITECTUAL CONCEPT403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
PRECISION HOME DEV INCGeneral Contractor208/26/2026
ROCK E SMALL PLBG&HTG INCPlumbing107/28/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ARCHITECTURAL CONCEPT3642204/03/2026
TRIANGLE INSPECTION & TES7495104/03/2026
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedROCK E SMALL PLBG&HTG INC07/27/2026
DOB NOWStructuralPermit IssuedPRECISION HOME DEV INC07/21/2026
DOB NOWConstruction FencePermit IssuedPRECISION HOME DEV INC07/20/2026
▾Field Inspections (DOB CAP) — 1
DateTypeResultReport
08/12/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 3
DateRequirementInspectorRole
04/02/2026Fire-Resistant Penetrations and JointsMUZAFFAR JAMALspecial
04/02/2026Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationMUZAFFAR JAMALspecial
04/02/2026Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention FacilitiesRajasekhar Sakhamurispecial
▾Documents — 19 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/17/2026Q01368997-I1Request digital key ↗
08/17/2026Q01368996-I1Request digital key ↗
08/17/2026Q01368996-S1Request digital key ↗
▸Zoning, Tax Lot & Property Records2
▸DOB NOWZD1: DOB Zoning Diagram1
08/17/2026Q01368996-I1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/17/2026Q01368996-I1Open ↗
▸Seals & Professional Certifications5
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/17/2026Q01368997-I1Open ↗
08/17/2026Q01368996-I1Open ↗
08/17/2026Q01368996-S1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/27/2026Q01368996-S1Open ↗
08/27/2026Q01368996-S1Open ↗
▸Safety & Tenant Protection1
▸DOB NOWStreet Tree Checklist1
08/17/2026Q01368996-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/17/2026Q01368996-I1Open ↗
08/17/2026Q01368996-S1Open ↗
▸Inspections & Test Reports1
▸DOB NOWGeotechnical Report (BC 1803.6)1
08/17/2026Q01368996-I1Open ↗
▸Other Documents5
▸DOB NOWProperty Ownership Certification1
08/17/2026Q01368996-I1Open ↗
▸DOB NOWSite Survey: Initial1
08/17/2026Q01368996-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/17/2026Q01368996-I1Open ↗
▸DOB NOWAdjoining Owners Notification1
08/17/2026Q01368996-I1Open ↗
▸DOB NOWPlot Diagram1
08/17/2026Q01368996-I1Open ↗