| Firm | Filings | Most Recent |
|---|---|---|
| AGT ARCHITECTURE P.C. | 3 | 01/19/2026 |
| Representative | Filings | Most Recent |
|---|---|---|
| FANG ARCHITECT | 3 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| URENA CONST & DESIGN INC | General Contractor | 1 | 07/08/2026 |
| INFINITI ESC PLUMBING COR | Plumbing | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| FANG ARCHITECT | 5513 | 3 | 01/19/2026 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Plumbing | Signed-off | INFINITI ESC PLUMBING COR | 08/05/2025 |
| DOB NOW | General Construction | Signed-off | URENA CONST & DESIGN INC | 06/18/2025 |
| Date | Type | Result | Report |
|---|---|---|---|
| 01/29/2026 | Pass-Final General Construction Non-Directive 14 | Pass | View ↗ |
| 01/26/2026 | Certified Water and Sanitary-WS-Fixtures-Finish | Certified | View ↗ |
| 12/22/2025 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 08/12/2025 | Certified Gas-Gas-Piping-Roughing | Certified | View ↗ |
| 08/12/2025 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 08/12/2025 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 01/07/2026 | Fire-Resistant Penetrations and Joints | DEZHANG FANG | special |
| 01/07/2026 | Energy Code Compliance Inspections | DEZHANG FANG | progress |
| 01/07/2026 | HVAC-R and service water heating system controls | DEZHANG FANG | energy_progress |
| 01/07/2026 | HVAC-R and service water heating equipment | DEZHANG FANG | energy_progress |
| 01/07/2026 | Maintenance information | DEZHANG FANG | energy_progress |
| 01/07/2026 | HVAC-R and service water piping design and insulation | DEZHANG FANG | energy_progress |
| 03/27/2025 | Structural Stability – Alterations of existing buildings | DEZHANG FANG | special |
| 03/24/2025 | Fire-Resistant Penetrations and Joints | DEZHANG FANG | special |
| 03/24/2025 | Energy Code Compliance Inspections | DEZHANG FANG | progress |
| 03/24/2025 | Fire-Resistance Rated Construction | DEZHANG FANG | progress |
| 03/24/2025 | Fenestration and door U-factor and product ratings | DEZHANG FANG | energy_progress |
| 03/24/2025 | Fenestration air leakage | DEZHANG FANG | energy_progress |
| 03/24/2025 | Insulation placement and R values | DEZHANG FANG | energy_progress |
| 03/24/2025 | Fenestration areas | DEZHANG FANG | energy_progress |
| 03/24/2025 | Interior lighting power | DEZHANG FANG | energy_progress |