← Back
One story - permanent living quarter
187-04 ILION AVENUE
QUEENS · BIN 4221787
💬 Discuss this project
1920Year Built
1.5Stories
A2Building Class
R2Zoning
1,194 sfGross Floor Area
1Units
2 Open Violations 0 unresolved · 2 paperwork only ▸FDNY Report ↗
One story - permanent living quarter · 6,000 sf lot · 0.2 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralPlumbing
Roof4p · 1 filing · 20 docs
Floor 22p · 1 filing · 20 docs
Floor 15p · 3 filings · 20 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
DDG ARCHITECTURE, P.C.1008/23/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
D+DG ARCHITECTURE603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
BUILT QUICK INCGeneral Contractor903/21/2026
CHATEL CONSTRUCTION CORPGeneral Contractor404/09/2026
2AK LIGHT ELECTRIC CORPElectrical103/22/2026
EH PLUMBING & HEATING CORPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
HPL ENGINEERING PC5613808/23/2026
Building Lifecycle
All (64)Filed (10)Permit Issued (8)Signed Off (3)Violation (2)Inspection (3)Objection (8)Special Inspection (30)
09/14/2026
Signed off — Alteration
Interior renovation and enlargement at 1st floor. No change in the use, occupancy or egress of the building.
Q00715999-I1
08/23/2026
Filed — Alteration
Interior removals/demo of entire 1st floor. New interior partitions ( new bathroom, Bedroom and kitchen layouts) exterior insulation, new finishes, interior doors, hardware throughout work throughout. No change in use, occupancy, egress, or bulk.
Q00655632-P2
08/14/2026
Special inspection requirement — Air barrier - visual inspection
08/14/2026
Special inspection requirement — Structural Steel - Details
Fran Huang
08/14/2026
Special inspection requirement — Structural Wood Frame
Fran Huang
08/14/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
08/14/2026
Special inspection requirement — Final
Fran Huang
08/14/2026
Special inspection requirement — Fenestration air leakage
08/14/2026
Special inspection requirement — Concrete - Cast-In-Place
Fran Huang
08/14/2026
Special inspection requirement — Final
Fran Huang
08/14/2026
Special inspection requirement — Lighting in dwelling units
08/14/2026
Special inspection requirement — Fenestration areas
08/14/2026
Special inspection requirement — Mechanical Systems
Fran Huang
08/14/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
Fran Huang
08/14/2026
Special inspection requirement — Permanent certificate
Fran Huang
08/14/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
Fran Huang
08/14/2026
Special inspection requirement — Masonry
Fran Huang
08/14/2026
Special inspection requirement — Structural Steel - High Strength Bolting
Fran Huang
08/14/2026
Special inspection requirement — Subgrade Inspections
Fran Huang
08/14/2026
Special inspection requirement — Footing and Foundation
Fran Huang
08/14/2026
Special inspection requirement — Structural Steel - Welding
Fran Huang
08/14/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Fran Huang
08/14/2026
Special inspection requirement — Wood – Seismic Resistance
Fran Huang
08/14/2026
Special inspection requirement — Insulation placement and R values
08/14/2026
Special inspection requirement — Fire-Resistance Rated Construction
Fran Huang
07/29/2026
Objection resolved — Resolved
07/24/2026
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
07/24/2026
Objection raised — Scope
07/22/2026
Filed — Alteration
Interior renovation and enlargement at 1st floor. No change in the use, occupancy or egress of the building.
Q00715999-P5
07/16/2026
Signed off — Alteration
New plumbing work for non-gas plumbing fixtures at existing Attic bathroom, 1st Floor bathroom and kitchen all per plan. No change in use, occupancy or egress with this application.
Q00678586-I1
07/14/2026
Signed off — Alteration
Q00744123-I1
07/08/2026
Special inspection requirement — Permanent certificate
Fran Huang
07/08/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
Fran Huang
07/08/2026
Special inspection requirement — Mechanical Systems
Fran Huang
07/08/2026
Special inspection requirement — Masonry
Fran Huang
07/08/2026
Special inspection requirement — Final
Fran Huang
07/06/2026
Objection resolved — Addressed
07/02/2026
Objection raised — Scope
06/30/2026
Filed — Alteration
Interior removals/demo of entire 1st floor. New interior partitions ( new bathroom, Bedroom and kitchen layouts) exterior insulation, new finishes, interior doors, hardware throughout work throughout. No change in use, occupancy, egress, or bulk.
Q00655632-P1
05/27/2026
Special inspection requirement — Permanent certificate
04/24/2026
Objection resolved — Resolved
02/06/2026
Objection raised — Cost
01/15/2026
Filed — Alteration
Interior renovation and enlargement at 1st floor. No change in the use, occupancy or egress of the building.
Q00715999-P4
12/29/2025
Special inspection requirement — Insulation placement and R values
10/29/2025
Permit issued — Mechanical Systems
Q00655632-I1-MS
10/22/2025
Permit issued — Foundation
Q00715999-I1-ST
10/22/2025
Permit issued — Structural
Q00715999-I1-FO
10/22/2025
Permit issued — Structural
Q00715999-I1-GC
11/11/2022
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
11/09/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
10/28/2022
Permit issued — Plumbing
Q00678586-I1-PL
09/06/2022
Filed — Alteration
Interior renovation and enlargement at 1st floor. No change in the use, occupancy or egress of the building.
Q00715999-P2
08/25/2022
Objection resolved — Addressed
08/18/2022
Violation issued (ECB, open)
Site Safety
08/18/2022
Violation issued (ECB, open)
Unknown
08/14/2022
Objection raised — Scope
08/11/2022
Filed — Alteration
Interior renovation and enlargement at 1st floor. No change in the use, occupancy or egress of the building.
Q00715999-P1
08/09/2022
Filed — Alteration
New plumbing work for non-gas plumbing fixtures at existing Attic bathroom, 1st Floor bathroom and kitchen all per plan. No change in use, occupancy or egress with this application.
Q00678586-I1
08/03/2022
Permit issued — Structural
Q00715999-I1-GC
06/15/2022
Permit issued — Construction Fence
Q00744123-I1-FN
Latest 60 of 64 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offCHATEL CONSTRUCTION CORP10/29/2025
DOB NOWFoundationSigned-offCHATEL CONSTRUCTION CORP10/22/2025
DOB NOWStructuralSigned-offCHATEL CONSTRUCTION CORP10/22/2025
DOB NOWStructuralSigned-offCHATEL CONSTRUCTION CORP10/22/2025
DOB NOWPlumbingSigned-offEH PLUMBING & HEATING COR10/28/2022
DOB NOWStructuralSigned-offBUILT QUICK INC08/03/2022
DOB NOWConstruction FenceSigned-offBUILT QUICK INC06/15/2022
DOB NOWMechanical SystemsSigned-offBUILT QUICK INC04/11/2022
BISOTISSUEDSUNRUN INSTALLATION SVC09/20/2017
1 project · most recent 08/23/2026
Others
FiledStatusContractorScopeMake / Model / Capacity
08/23/2026Signed-offCHATEL CONSTRUCTION CORPOthers
Other
Mitsubishi Electric MXZ-3C24NA3-U1 66,000 BTU · Condensing Unit ×3
Greenheck SP-AP0511WP 75 CFM · Exhaust Fan ×1
3 projects · most recent 08/27/2026
General Wiring
FiledStatusContractorScope
08/27/2026CompleteBELLA CRUISE ELECTRICALGeneral Wiring
02/19/2026Complete2AK LIGHT ELECTRIC CORPGeneral Wiring
05/03/2022CancelledADAM ELECL CONTRNG LLCGeneral Wiring
1 project · most recent 07/22/2026
Steel Concrete Wood
FiledStatusContractorScope
07/22/2026Signed-offCHATEL CONSTRUCTION CORPSteel, Concrete, Wood
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
07/24/2026Fail-Final General Construction Non-Directive 14FailView ↗
11/11/2022Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
11/09/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 72
DateRequirementInspectorRole
08/14/2026Air barrier - visual inspection—energy_progress
08/14/2026Permanent certificateFran Huangenergy_progress
08/14/2026FinalFran Huangprogress
08/14/2026Structural Stability – Alterations of existing buildingsFran Huangspecial
08/14/2026Mechanical SystemsFran Huangspecial
08/14/2026Fenestration air leakage—energy_progress
08/14/2026MasonryFran Huangspecial
08/14/2026Subgrade InspectionsFran Huangspecial
08/14/2026Structural Steel - High Strength BoltingFran Huangspecial
08/14/2026Structural Steel - WeldingFran Huangspecial
08/14/2026Wood – Seismic ResistanceFran Huangspecial
08/14/2026Fire-Resistant Penetrations and JointsFran Huangspecial
08/14/2026Concrete - Cast-In-PlaceFran Huangspecial
08/14/2026Structural Steel - DetailsFran Huangspecial
08/14/2026Structural Stability – Alterations of existing buildingsFran Huangspecial
08/14/2026Fire-Resistance Rated ConstructionFran Huangprogress
08/14/2026Footing and FoundationFran Huangprogress
08/14/2026FinalFran Huangprogress
08/14/2026Structural Wood FrameFran Huangprogress
08/14/2026Lighting in dwelling units—energy_progress
08/14/2026Insulation placement and R values—energy_progress
08/14/2026Fenestration areas—energy_progress
08/14/2026Fenestration and door U-factor and product ratings—energy_progress
07/08/2026MasonryFran Huangspecial
07/08/2026Permanent certificateFran Huangenergy_progress
Latest 25 of 72.
▾Documents — 126 on file (BIS + DOB NOW)
▸Plans & Drawings10
▸DOB NOWPlans/Sketch10
08/26/2026Q00655632-P2Request digital key ↗
08/26/2026Q00655632-I1Request digital key ↗
08/26/2026Q00744123-I1Request digital key ↗
Showing 3 of 10 on file for this type
▸Applications & Permits2
▸BISPLAN / WORK APPROVAL APPLICATION1
09/19/2017440435593Open ↗
▸BISWORK PERMIT APPLICATION1
09/19/2017440435593Open ↗
▸Zoning, Tax Lot & Property Records5
▸DOB NOWZD1: DOB Zoning Diagram5
08/15/2026Q00715999-P5Open ↗
08/13/2026Q00715999-P1Open ↗
08/13/2026Q00715999-P4Open ↗
Showing 3 of 5 on file for this type
▸Seals & Professional Certifications68
▸DOB NOWSpecial Inspector Seal & Signature34
09/23/2026Q00655632-P2Open ↗
09/23/2026Q00655632-P2Open ↗
08/31/2026Q00655632-P1Open ↗
Showing 3 of 34 on file for this type
▸DOB NOWProgress Inspector Seal & Signature21
09/23/2026Q00655632-P2Open ↗
09/23/2026Q00655632-P2Open ↗
08/31/2026Q00655632-P1Open ↗
Showing 3 of 21 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature10
08/26/2026Q00655632-P2Open ↗
08/26/2026Q00655632-P1Open ↗
08/26/2026Q00655632-I1Open ↗
Showing 3 of 10 on file for this type
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
09/19/2017440435593Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
09/19/2017440435593Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
09/19/2017440435593Open ↗
▸Safety & Tenant Protection1
▸BISTENANT PROTECTION PLAN AND NOTES1
09/19/2017440435593Open ↗
▸Environmental & Asbestos10
▸DOB NOWDEP ACP-5: Asbestos Assessment Report9
08/26/2026Q00655632-P2Open ↗
08/26/2026Q00655632-I1Open ↗
08/25/2026Q00715999-I1Open ↗
Showing 3 of 9 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
09/19/2017440435593Open ↗
▸Energy Compliance7
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY2
11/22/2017440435593Open ↗
09/19/2017440435593Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
09/19/2017440435593Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
11/22/2017440435593Open ↗
▸BISSOLAR TAX ABATEMENT APPLICATION1
11/22/2017440435593Open ↗
▸BISNYCECC ANALYSIS1
09/19/2017440435593Open ↗
▸BISPTA4: SOLAR TAX ABATEMENT APPLICATION (PRELIMINARY)1
09/19/2017440435593Open ↗
▸Inspections & Test Reports2
▸BISTECHNICAL REPORT: RESPONSIBILITY2
11/22/2017440435593Open ↗
09/19/2017440435593Open ↗
▸Approvals, Objections & Sign-offs3
▸BISUtility Company PV System Interconnection Acknowledgement Letter1
11/22/2017440435593Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION1
11/22/2017440435593Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
11/22/2017440435593Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
11/22/2017440435593Open ↗
09/19/2017440435593Open ↗
▸Filing & Intake Forms1
▸BISEFILING JOB APPLICATION COVER SHEET1
09/19/2017440435593Open ↗
▸Other Documents15
▸DOB NOWSite Survey: Initial5
08/25/2026Q00715999-I1Open ↗
08/15/2026Q00715999-P5Open ↗
08/13/2026Q00715999-P2Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone5
08/15/2026Q00715999-P5Open ↗
08/13/2026Q00715999-P4Open ↗
08/13/2026Q00715999-P2Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWPlot Diagram5
08/15/2026Q00715999-P5Open ↗
08/13/2026Q00715999-P4Open ↗
08/13/2026Q00715999-I1Open ↗
Showing 3 of 5 on file for this type