← Back
Two family converted from one family
188-03 ILION AVENUE
QUEENS · BIN 4221977
💬 Discuss this project
1925Year Built
2Stories
B3Building Class
R2Zoning
2,370 sfGross Floor Area
2Units
Two family converted from one family · 6,000 sf lot · 0.4 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Permit Issued — active, not yet Signed-off
Floor 2Under Construction2p · 1 filing · 15 docs
Floor 1
CellarUnder Construction3p · 1 filing · 15 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
SUNG HO SHIN ARCHITECT, PC307/28/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
MEIR GLAZERGeneral Contractor109/19/2026
Building Lifecycle
All (8)Filed (3)Permit Issued (1)Objection (4)
09/18/2026
Permit issued — Construction Fence
Q01350165-S2-FN
07/28/2026
Filed — Alteration
Proposed one story horizontal addition, and minor interior renovation, and new concrete stair at cellar.
Q01350165-S2
04/29/2026
Objection resolved — Resolved
04/24/2026
Objection raised — Admin
04/24/2026
Objection raised — Admin
04/24/2026
Objection raised — Zoning
04/20/2026
Filed — Alteration
Proposed one story horizontal addition, and minor interior renovation, and new concrete stair at cellar.
Q01350165-I1
04/20/2026
Filed — Alteration
Proposed one story horizontal addition, and minor interior renovation, and new concrete stair at cellar.
Q01350165-S1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWConstruction FencePermit IssuedMEIR GLAZER09/18/2026
1 project · most recent 07/28/2026
Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
07/28/2026Permit IssuedMEIR GLAZER CONSTRUCTIONHeating Systems, Ventilation Systems
Heating
Goodman GD9S800403AN 40 BTU ×2
Ventilation
Panasonic FV-0510V51 100 CFM · Exhaust Fan ×1
1 project · most recent 07/28/2026
Gas Water/Sanitary
FiledStatusContractorScope
07/28/2026——Gas, Water/Sanitary
1 project · most recent 07/28/2026
Wood
FiledStatusContractorScope
07/28/2026Permit IssuedMEIR GLAZER CONSTRUCTIONWood
1 project · most recent 07/28/2026
Fence
FiledStatusContractorScope
07/28/2026Permit IssuedMEIR GLAZER CONSTRUCTIONFence
▾Special Inspection Requirements (DOB NOW) — 1
DateRequirementInspectorRole
04/17/2026Fire-Resistant Penetrations and Joints—special
▾Documents — 15 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/17/2026Q01350165-S2Request digital key ↗
08/15/2026Q01350165-S1Request digital key ↗
08/15/2026Q01350165-I1Request digital key ↗
▸Zoning, Tax Lot & Property Records4
▸DOB NOWRestrictive Declaration/Easement 13
08/17/2026Q01350165-S2Open ↗
08/15/2026Q01350165-S1Open ↗
08/15/2026Q01350165-I1Open ↗
▸DOB NOWZD1: DOB Zoning Diagram1
08/15/2026Q01350165-I1Open ↗
▸Seals & Professional Certifications3
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/17/2026Q01350165-S1Open ↗
08/17/2026Q01350165-I1Open ↗
08/17/2026Q01350165-S2Open ↗
▸Inspections & Test Reports1
▸DOB NOWGeotechnical Report (BC 1803.6)1
08/15/2026Q01350165-I1Open ↗
▸Other Documents4
▸DOB NOWAdjoining Owners Notification1
08/15/2026Q01350165-I1Open ↗
▸DOB NOWPlot Diagram1
08/15/2026Q01350165-I1Open ↗
▸DOB NOWSite Survey: Initial1
08/15/2026Q01350165-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/15/2026Q01350165-I1Open ↗