← Back
Two stories - detached, small or mid-size
221-54 92 AVENUE
QUEENS · BIN 4230146
💬 Discuss this project
1925Year Built
2Stories
A1Building Class
R3AZoning
1,120 sfGross Floor Area
1Units
Two stories - detached, small or mid-size · 3,000 sf lot · 0.37 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
1 job · most recent 08/20/2026
Air Conditioning Systems Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
08/20/2026——Air Conditioning Systems, Heating Systems, Ventilation Systems
Cooling
Carrier 27VPA960A*030* 60,000 BTU · Condensing Unit ×1
Heating
Carrier 59MN7C120C24--22 120,000 BTU · Furnace ×1
Ventilation
Hampton Bay 7114-01 50 CFM · Exhaust Fan ×3
Delta Breeze SMT150 150 CFM · Exhaust Fan ×1
1 job · most recent 08/20/2026
Gas Water/Sanitary
FiledStatusContractorScope
08/20/2026——Gas, Water/Sanitary
1 job · most recent 08/20/2026
Fence
FiledStatusContractorScope
08/20/2026——Fence
Building Lifecycle
All (30)Filed (1)Objection (4)Special Inspection (25)
09/03/2026
Objection resolved — Addressed
09/03/2026
Objection resolved — Addressed
09/01/2026
Objection raised — Other
09/01/2026
Objection raised — Other
08/20/2026
Filed — Alteration
INSTALLATION OF TEMPORARY CONSTRUCTION FENCE IN CONJUNCTION WITH DOB NOW APPLICATION #Q01424866-I1. FENCE SHALL COMPLY WITH CHAPTER 33 OF THE NYC BUILDING CODE.
Q01424866-I1
07/28/2026
Special inspection requirement — Air barrier — testing
06/30/2026
Special inspection requirement — Concrete - Cast-In-Place
06/30/2026
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
06/30/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
06/30/2026
Special inspection requirement — Masonry
06/30/2026
Special inspection requirement — Structural Steel - Details
06/30/2026
Special inspection requirement — Structural Steel - High Strength Bolting
06/30/2026
Special inspection requirement — Subgrade Inspections
06/30/2026
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
06/30/2026
Special inspection requirement — Final
06/30/2026
Special inspection requirement — Footing and Foundation
06/30/2026
Special inspection requirement — Energy Code Compliance Inspections
06/30/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
06/30/2026
Special inspection requirement — Structural Wood Frame
06/30/2026
Special inspection requirement — Electric vehicle service equipment requirements
06/30/2026
Special inspection requirement — Fenestration air leakage
06/30/2026
Special inspection requirement — Maintenance information
06/30/2026
Special inspection requirement — Metering
06/30/2026
Special inspection requirement — Permanent certificate
06/30/2026
Special inspection requirement — Interior lighting power
06/30/2026
Special inspection requirement — Insulation placement and R values
06/30/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
06/30/2026
Special inspection requirement — Air barrier - visual inspection
06/30/2026
Special inspection requirement — Fenestration areas
06/30/2026
Special inspection requirement — Fire-Resistance Rated Construction
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NKM ENGINEERING PLLC108/20/2026
Nothing on file for this building.
▾Special Inspection Requirements (DOB NOW) — 25
DateRequirementInspectorRole
07/28/2026Air barrier — testing —energy_progress
06/30/2026Concrete - Cast-In-Place—special
06/30/2026Excavations - Sheeting, Shoring, and Bracing—special
06/30/2026Fire-Resistant Penetrations and Joints—special
06/30/2026Masonry—special
06/30/2026Structural Steel - Details—special
06/30/2026Structural Steel - High Strength Bolting—special
06/30/2026Subgrade Inspections—special
06/30/2026Subsurface Investigations (Borings/Test Pits)—special
06/30/2026Final—progress
06/30/2026Footing and Foundation—progress
06/30/2026Energy Code Compliance Inspections—progress
06/30/2026Structural Stability – Alterations of existing buildings—special
06/30/2026Structural Wood Frame—progress
06/30/2026Electric vehicle service equipment requirements—energy_progress
06/30/2026Fenestration air leakage—energy_progress
06/30/2026Maintenance information—energy_progress
06/30/2026Metering—energy_progress
06/30/2026Permanent certificate—energy_progress
06/30/2026Interior lighting power—energy_progress
06/30/2026Insulation placement and R values—energy_progress
06/30/2026Fenestration and door U-factor and product ratings—energy_progress
06/30/2026Air barrier - visual inspection—energy_progress
06/30/2026Fenestration areas—energy_progress
06/30/2026Fire-Resistance Rated Construction—progress
▾Documents — 17 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/21/2026Q01424866-S1Request digital key ↗
08/21/2026Q01424866-I1Request digital key ↗
▸Zoning, Tax Lot & Property Records2
▸DOB NOWZD1: DOB Zoning Diagram2
09/24/2026Q01424866-I1Open ↗
08/21/2026Q01424866-I1Open ↗
▸Seals & Professional Certifications4
▸DOB NOWDPL-1: Design Professional Seal & Signature4
09/24/2026Q01424866-S3Open ↗
09/24/2026Q01424866-S2Open ↗
09/24/2026Q01424866-S1Open ↗
Showing 3 of 4 on file for this type
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
09/24/2026Q01424866-S3Open ↗
09/24/2026Q01424866-S2Open ↗
08/21/2026Q01424866-S3Open ↗
Showing 3 of 5 on file for this type
▸Inspections & Test Reports1
▸DOB NOWSOIL REPORT1
08/21/2026Q01424866-I1Open ↗
▸Other Documents3
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
09/24/2026Q01424866-I1Open ↗
▸DOB NOWSite Survey: Initial1
08/21/2026Q01424866-I1Open ↗
▸DOB NOWPlot Diagram1
09/24/2026Q01424866-I1Open ↗