← Back
Two stories - detached, small or mid-size
115-12 197 STREET
QUEENS · BIN 4237506
💬 Discuss this project
1930Year Built
2.5Stories
A1Building Class
R3AZoning
1,408 sfGross Floor Area
1Units
Two stories - detached, small or mid-size · 2,700 sf lot · 0.52 FAR built · Flood zone X
Locations of Work
Architecture
Floor 22p · 1 filing · 6 docs
Floor 1
Cellar1p · 1 filing · 6 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
CD ARCHITECT STUDIO, LLP106/20/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
JON PAUL DESIGN & CONSULTING203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
TRINCHESE CONSTRUCTION INGeneral Contractor104/09/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
CD ARCHITECT STUDIO, LLP2573106/20/2025
Building Lifecycle
All (21)Filed (1)Permit Issued (1)Signed Off (1)Inspection (3)Objection (4)Special Inspection (11)
01/09/2026
Signed off — Alteration
RESTORE EX. 1-FAMILY DWELLING & REPAIR FIRE DAMAGES INCLUDING GENERAL CONSTRUCTION, MINOR STRUCTURAL REPAIR & COSMETIC FINISHES. NO CHANGE TO EGRESS, USE OR OCCUPANCY.
Q01237721-I1
12/11/2025
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
11/24/2025
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
11/06/2025
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
07/07/2025
Permit issued — General Construction
Q01237721-I1-GC-CX
07/03/2025
Objection resolved — Addressed
07/02/2025
Objection resolved — Addressed
07/01/2025
Objection raised — Zoning
07/01/2025
Objection raised — Cost
06/20/2025
Filed — Alteration
RESTORE EX. 1-FAMILY DWELLING & REPAIR FIRE DAMAGES INCLUDING GENERAL CONSTRUCTION, MINOR STRUCTURAL REPAIR & COSMETIC FINISHES. NO CHANGE TO EGRESS, USE OR OCCUPANCY.
Q01237721-I1
06/06/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
Nat Costanza
06/06/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Nat Costanza
06/06/2025
Special inspection requirement — Final
Nat Costanza
06/06/2025
Special inspection requirement — Energy Code Compliance Inspections
Nat Costanza
06/06/2025
Special inspection requirement — Fire-Resistance Rated Construction
Nat Costanza
06/06/2025
Special inspection requirement — Fenestration air leakage
Nat Costanza
06/06/2025
Special inspection requirement — Air barrier - visual inspection
Nat Costanza
06/06/2025
Special inspection requirement — Insulation placement and R values
Nat Costanza
06/06/2025
Special inspection requirement — Fenestration areas
Nat Costanza
06/06/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
Nat Costanza
06/06/2025
Special inspection requirement — Interior lighting power
Nat Costanza
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offTRINCHESE CONSTRUCTION IN07/07/2025
BISOTISSUEDGREEN STREET POWER PARTNE10/21/2015
Nothing on file for this building.
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
12/11/2025Pass-Final General Construction Non-Directive 14PassView ↗
11/24/2025Fail-Final General Construction Non-Directive 14FailView ↗
11/06/2025Fail-Final General Construction Non-Directive 14FailView ↗
▾Special Inspection Requirements (DOB NOW) — 11
DateRequirementInspectorRole
06/06/2025Structural Stability – Alterations of existing buildingsNat Costanzaspecial
06/06/2025Fire-Resistant Penetrations and JointsNat Costanzaspecial
06/06/2025FinalNat Costanzaprogress
06/06/2025Energy Code Compliance InspectionsNat Costanzaprogress
06/06/2025Fire-Resistance Rated ConstructionNat Costanzaprogress
06/06/2025Fenestration air leakageNat Costanzaenergy_progress
06/06/2025Air barrier - visual inspectionNat Costanzaenergy_progress
06/06/2025Insulation placement and R valuesNat Costanzaenergy_progress
06/06/2025Fenestration areasNat Costanzaenergy_progress
06/06/2025Fenestration and door U-factor and product ratingsNat Costanzaenergy_progress
06/06/2025Interior lighting powerNat Costanzaenergy_progress
▾Documents — 24 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/19/2026Q01237721-I1Request digital key ↗
▸Applications & Permits2
▸BISPLAN / WORK APPROVAL APPLICATION1
10/20/2015440246869Open ↗
▸BISWORK PERMIT APPLICATION1
10/21/2015440246869Open ↗
▸Seals & Professional Certifications5
▸DOB NOWProgress Inspector Seal & Signature2
08/31/2026Q01237721-I1Open ↗
08/31/2026Q01237721-I1Open ↗
▸BISAPPLICANT OWNER SIGNATURE1
10/20/2015440246869Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/19/2026Q01237721-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/31/2026Q01237721-I1Open ↗
▸Environmental & Asbestos2
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
10/20/2015440246869Open ↗
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/19/2026Q01237721-I1Open ↗
▸Energy Compliance5
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY2
05/12/2017440246869Open ↗
10/20/2015440246869Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
05/12/2017440246869Open ↗
▸BISSOLAR TAX ABATEMENT APPLICATION1
10/20/2015440246869Open ↗
▸BISPTA4: SOLAR TAX ABATEMENT APPLICATION (FINAL)1
05/16/2017440246869Open ↗
▸Inspections & Test Reports2
▸BISTECHNICAL REPORT: RESPONSIBILITY2
05/12/2017440246869Open ↗
10/20/2015440246869Open ↗
▸Approvals, Objections & Sign-offs3
▸BISLETTERS - SUPPORTING DOCUMENTATION1
05/12/2017440246869Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
05/12/2017440246869Open ↗
▸BISUtility Company PV System Interconnection Acknowledgement Letter1
05/12/2017440246869Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
05/12/2017440246869Open ↗
10/20/2015440246869Open ↗
▸Filing & Intake Forms2
▸BISADDITIONAL INFORMATION1
03/08/2016440246869Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
10/20/2015440246869Open ↗