← Back
Two stories - detached, small or mid-size
109-23 111 STREET
QUEENS · BIN 4249161
💬 Discuss this project
1925Year Built
2.5Stories
A1Building Class
R4AZoning
1,468 sfGross Floor Area
1Units
1 Open Violation 0 unresolved · 1 paperwork only ▸FDNY Report ↗
Two stories - detached, small or mid-size · 3,068 sf lot · 0.48 FAR built · Flood zone X
Locations of Work
ArchitectureElectricalFire Protection
Permit Issued — active, not yet Signed-off
Floor 3Under Construction12p · 2 filings · 20 docs
Floor 2Under Construction10p · 1 filing · 20 docs
Floor 1Under Construction11p · 1 filing · 20 docs
CellarUnder Construction12p · 2 filings · 20 docs
1 job · most recent 01/15/2025
Air Conditioning Systems Associated Ducts and Piping Heating Systems
FiledStatusContractorScopeMake / Model / Capacity
01/15/2025——Air Conditioning Systems, Associated Ducts and Piping, Heating Systems
Cooling
Ecoer EODA18H-4860 5 tons · Pump ×2
Heating
Ecoer EODA18H-4860 5 tons · Heat Pump Outdoor ×2
Ducts & Piping
Ecoer EAHATN-60 54,000 BTU · Heat Pump Outdoor ×2
1 job · most recent 01/09/2026
FiledStatusContractorScope
01/09/2026——39 heads
2 jobs · most recent 01/09/2026
Gas Water/Sanitary
FiledStatusContractorScope
01/09/2026———
01/15/2025——Gas, Water/Sanitary
Building Lifecycle
All (100)Filed (7)Permit Issued (2)Violation (1)Objection (60)Special Inspection (30)
05/26/2026
Violation issued (ECB, open)
Construction
05/08/2026
Permit issued — General Construction
Q00690100-I1-GC
04/02/2026
Permit issued — Construction Fence
Q01337238-I1-FN
02/09/2026
Objection resolved — Addressed
02/09/2026
Objection resolved — Addressed
02/09/2026
Objection resolved — Addressed
02/09/2026
Objection resolved — Addressed
02/09/2026
Objection resolved — Addressed
01/22/2026
Objection raised — Fire_Protection
01/22/2026
Objection raised — Fire_Protection
01/22/2026
Objection raised — Fire_Protection
01/22/2026
Objection raised — Cost
01/22/2026
Objection raised — Fire_Protection
01/09/2026
Filed — Alteration
Proposed sprinkler system as per plan filed in conjunction with Alt-CO # Q00690100.
Q01334686-I1
12/20/2025
Filed — Alteration
Q01337238-I1
12/16/2025
Special inspection requirement — Seismic Isolation Systems
12/16/2025
Special inspection requirement — Post-installed Anchors
12/16/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
12/16/2025
Special inspection requirement — Sprinkler Systems
10/07/2025
Objection resolved — Addressed
10/07/2025
Objection resolved — Addressed
10/06/2025
Special inspection requirement — HVAC-R and service water heating equipment
GLEN LANGER
10/06/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
GLEN LANGER
10/06/2025
Special inspection requirement — Maintenance information
GLEN LANGER
10/06/2025
Special inspection requirement — Ventilation and air distribution system
GLEN LANGER
10/06/2025
Special inspection requirement — HVAC-R and service water heating system controls
GLEN LANGER
10/06/2025
Special inspection requirement — Duct leakage testing, insulation and design
GLEN LANGER
09/30/2025
Objection resolved — Addressed
09/30/2025
Objection resolved — Addressed
09/30/2025
Objection resolved — Addressed
09/30/2025
Objection resolved — Addressed
09/15/2025
Special inspection requirement — Fenestration air leakage
GLEN LANGER
09/15/2025
Special inspection requirement — Air barrier — testing
GLEN LANGER
09/15/2025
Special inspection requirement — Metering
GLEN LANGER
09/15/2025
Special inspection requirement — Air barrier - visual inspection
GLEN LANGER
09/15/2025
Special inspection requirement — Insulation placement and R values
GLEN LANGER
09/15/2025
Special inspection requirement — Interior lighting power
GLEN LANGER
09/15/2025
Special inspection requirement — Electric vehicle service equipment requirements
GLEN LANGER
09/15/2025
Special inspection requirement — Permanent certificate
GLEN LANGER
09/15/2025
Special inspection requirement — Fenestration areas
GLEN LANGER
09/15/2025
Special inspection requirement — Masonry
GLEN LANGER
09/15/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
GLEN LANGER
09/15/2025
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
GLEN LANGER
09/15/2025
Special inspection requirement — Concrete - Precast
GLEN LANGER
09/15/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
GLEN LANGER
09/15/2025
Special inspection requirement — Subgrade Inspections
GLEN LANGER
09/15/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
GLEN LANGER
09/15/2025
Special inspection requirement — Concrete - Cast-In-Place
GLEN LANGER
09/15/2025
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
GLEN LANGER
09/15/2025
Special inspection requirement — Protection of exposed foundation insulation
GLEN LANGER
09/15/2025
Special inspection requirement — Maintenance information
GLEN LANGER
08/25/2025
Objection resolved — Addressed
07/25/2025
Objection raised — Other
07/06/2025
Objection resolved — Addressed
06/12/2025
Objection raised — Other
05/27/2025
Objection resolved — Addressed
04/28/2025
Objection raised — Other
04/15/2025
Filed — Alteration CO
APPLICATION FILED TO CHANGE C OF O FROM 1 FAMILY TO 2 FAMILY WITH HORIZONTAL AND VERTICAL EXTENSION AND INTERIOR RENOVATIONS.
Q00690100-P1
01/30/2025
Objection resolved — Addressed
01/30/2025
Objection resolved — Addressed
Latest 60 of 100 events.
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
SHARON ENGINEERING, P.C101/09/2026
SOUTHERN CONSULTING ENGINEERING PC612/20/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
VERNON21203/21/2026
BMB BUILDING CONSULTING203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
KAIETEUR CONSTRUCTION INC.General Contractor207/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
S&S CONCRETE & SOIL TESTI1008304/15/2025
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedKAIETEUR CONSTRUCTION INC.05/08/2026
DOB NOWConstruction FencePermit IssuedKAIETEUR CONSTRUCTION INC04/02/2026
BISPLISSUEDMASTERS MECHANICAL PLUMBING & HE11/08/1996
▾Special Inspection Requirements (DOB NOW) — 55
DateRequirementInspectorRole
12/16/2025Seismic Isolation Systems—special
12/16/2025Post-installed Anchors—special
12/16/2025Fire-Resistant Penetrations and Joints—special
12/16/2025Sprinkler Systems—special
10/06/2025HVAC-R and service water heating equipmentGLEN LANGERenergy_progress
10/06/2025HVAC-R and service water piping design and insulationGLEN LANGERenergy_progress
10/06/2025Maintenance informationGLEN LANGERenergy_progress
10/06/2025Ventilation and air distribution systemGLEN LANGERenergy_progress
10/06/2025HVAC-R and service water heating system controlsGLEN LANGERenergy_progress
10/06/2025Duct leakage testing, insulation and designGLEN LANGERenergy_progress
09/15/2025Fenestration air leakageGLEN LANGERenergy_progress
09/15/2025Air barrier — testing GLEN LANGERenergy_progress
09/15/2025MeteringGLEN LANGERenergy_progress
09/15/2025Air barrier - visual inspectionGLEN LANGERenergy_progress
09/15/2025Insulation placement and R valuesGLEN LANGERenergy_progress
09/15/2025Interior lighting powerGLEN LANGERenergy_progress
09/15/2025Electric vehicle service equipment requirementsGLEN LANGERenergy_progress
09/15/2025Permanent certificateGLEN LANGERenergy_progress
09/15/2025Fenestration areasGLEN LANGERenergy_progress
09/15/2025MasonryGLEN LANGERspecial
09/15/2025Fenestration and door U-factor and product ratingsGLEN LANGERenergy_progress
09/15/2025Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationGLEN LANGERspecial
09/15/2025Concrete - PrecastGLEN LANGERspecial
09/15/2025Fire-Resistant Penetrations and JointsGLEN LANGERspecial
09/15/2025Subgrade InspectionsGLEN LANGERspecial
Latest 25 of 55.
▾Documents — 48 on file (BIS + DOB NOW)
▸Plans & Drawings7
▸DOB NOWPlans/Sketch7
08/26/2026Q00720242-I1Request digital key ↗
08/21/2026Q00720240-I1Request digital key ↗
08/21/2026Q00720241-I1Request digital key ↗
Showing 3 of 7 on file for this type
▸Zoning, Tax Lot & Property Records2
▸DOB NOWZD1: DOB Zoning Diagram2
08/15/2026Q00690100-I1Open ↗
08/13/2026Q00690100-P1Open ↗
▸Seals & Professional Certifications22
▸DOB NOWProgress Inspector Seal & Signature12
09/27/2026Q00690100-P1Open ↗
09/27/2026Q00690100-P1Open ↗
09/27/2026Q00690100-P1Open ↗
Showing 3 of 12 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature7
08/26/2026Q00720242-I1Open ↗
08/21/2026Q00720241-I1Open ↗
08/20/2026Q00690100-I1Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature3
09/27/2026Q00690100-P1Open ↗
09/01/2026Q00690100-I1Open ↗
08/31/2026Q00720241-I1Open ↗
▸Safety & Tenant Protection3
▸DOB NOWStreet Tree Checklist2
08/15/2026Q00690100-P1Open ↗
08/15/2026Q00690100-I1Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/15/2026Q00690100-I1Open ↗
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/21/2026Q00720241-I1Open ↗
08/17/2026Q01334686-I1Open ↗
08/15/2026Q00690100-P1Open ↗
Showing 3 of 5 on file for this type
▸Other Documents9
▸DOB NOWPlot Diagram2
08/15/2026Q00690100-I1Open ↗
08/13/2026Q00690100-P1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone2
08/15/2026Q00690100-I1Open ↗
08/13/2026Q00690100-P1Open ↗
▸DOB NOWProperty Ownership Certification2
08/15/2026Q00690100-P1Open ↗
08/15/2026Q00690100-I1Open ↗
▸DOB NOWSite Survey: Initial2
08/15/2026Q00690100-I1Open ↗
08/13/2026Q00690100-P1Open ↗
▸DOB NOWFinal Survey1
08/15/2026Q00690100-I1Open ↗