← Back
One story - permanent living quarter
171-30 119 AVENUE
QUEENS · Baisley Park · BIN 4268215
💬 Discuss this project
1920Year Built
1.5Stories
A2Building Class
R3AZoning
1,045 sfGross Floor Area
1Units
One story - permanent living quarter · 3,360 sf lot · 0.31 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
MYRTLE DEVELOPMENT109/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
PIROOZ ENGINEERING, P.C.109/17/2026
Building Lifecycle
All (29)Filed (1)Special Inspection (28)
09/17/2026
Filed — Alteration CO
PROPOSED PLUMBING WORK IN CONJUNCTION WITH ALTERATION-CO APPLICATION # Q01450101-I1
Q01450101-I1
09/05/2026
Special inspection requirement — HVAC-R and service water heating system controls
09/05/2026
Special inspection requirement — Subgrade Inspections
09/05/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
09/05/2026
Special inspection requirement — HVAC-R and service water heating equipment
08/23/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
08/23/2026
Special inspection requirement — Heating Systems
08/23/2026
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
08/23/2026
Special inspection requirement — Final
08/23/2026
Special inspection requirement — Footing and Foundation
08/23/2026
Special inspection requirement — Energy Code Compliance Inspections
08/23/2026
Special inspection requirement — Fire-Resistance Rated Construction
08/23/2026
Special inspection requirement — Preliminary
08/23/2026
Special inspection requirement — Structural Wood Frame
08/23/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
08/23/2026
Special inspection requirement — Air barrier - visual inspection
08/23/2026
Special inspection requirement — Fenestration air leakage
08/23/2026
Special inspection requirement — Interior lighting power
08/23/2026
Special inspection requirement — Maintenance information
08/23/2026
Special inspection requirement — Electric vehicle service equipment requirements
08/23/2026
Special inspection requirement — Permanent certificate
08/23/2026
Special inspection requirement — Insulation placement and R values
08/23/2026
Special inspection requirement — Fenestration areas
08/23/2026
Special inspection requirement — Metering
08/23/2026
Special inspection requirement — Ventilation and air distribution system
08/23/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
08/23/2026
Special inspection requirement — Mechanical Systems
08/23/2026
Special inspection requirement — Concrete - Cast-In-Place
08/23/2026
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
Nothing on file for this building.
1 project · most recent 09/17/2026
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
09/17/2026——Heating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Tottokool Condensers - AAC5048E1000A Gas furnace - AGF96M120D5B 100,000 BTU · Split System ×2
Ventilation
Panasonic FV-06VE1 60 CFM · Exhaust Fan ×5
FV-15VQ5 150 CFM · Exhaust Fan ×2
1 project · most recent 09/17/2026
Concrete Wood
FiledStatusContractorScope
09/17/2026——Concrete, Wood
1 project · most recent 09/17/2026
Fence
FiledStatusContractorScope
09/17/2026——Fence
▾Special Inspection Requirements (DOB NOW) — 28
DateRequirementInspectorRole
09/05/2026HVAC-R and service water heating system controls—energy_progress
09/05/2026Subgrade Inspections—special
09/05/2026HVAC-R and service water piping design and insulation—energy_progress
09/05/2026HVAC-R and service water heating equipment—energy_progress
08/23/2026Fire-Resistant Penetrations and Joints—special
08/23/2026Heating Systems—special
08/23/2026Subsurface Investigations (Borings/Test Pits)—special
08/23/2026Final—progress
08/23/2026Footing and Foundation—progress
08/23/2026Energy Code Compliance Inspections—progress
08/23/2026Fire-Resistance Rated Construction—progress
08/23/2026Preliminary—progress
08/23/2026Structural Wood Frame—progress
08/23/2026Structural Stability – Alterations of existing buildings—special
08/23/2026Air barrier - visual inspection—energy_progress
08/23/2026Fenestration air leakage—energy_progress
08/23/2026Interior lighting power—energy_progress
08/23/2026Maintenance information—energy_progress
08/23/2026Electric vehicle service equipment requirements—energy_progress
08/23/2026Permanent certificate—energy_progress
08/23/2026Insulation placement and R values—energy_progress
08/23/2026Fenestration areas—energy_progress
08/23/2026Metering—energy_progress
08/23/2026Ventilation and air distribution system—energy_progress
08/23/2026Fenestration and door U-factor and product ratings—energy_progress
Latest 25 of 28.
▾Documents — 9 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
09/21/2026Q01450101-I1Request digital key ↗
▸Zoning, Tax Lot & Property Records1
▸DOB NOWZD1: DOB Zoning Diagram1
09/21/2026Q01450101-I1Open ↗
▸Seals & Professional Certifications1
▸DOB NOWDPL-1: Design Professional Seal & Signature1
09/21/2026Q01450101-I1Open ↗
▸Safety & Tenant Protection1
▸DOB NOWStreet Tree Checklist1
09/21/2026Q01450101-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
09/21/2026Q01450101-I1Open ↗
▸Inspections & Test Reports1
▸DOB NOWSOIL REPORT1
09/21/2026Q01450101-I1Open ↗
▸Other Documents3
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
09/21/2026Q01450101-I1Open ↗
▸DOB NOWProperty Ownership Certification1
09/21/2026Q01450101-I1Open ↗
▸DOB NOWSite Survey: Initial1
09/21/2026Q01450101-I1Open ↗