← Back
Two family converted from one family
240-18 144 AVENUE
QUEENS · BIN 4287992
💬 Discuss this project
1925Year Built
2.5Stories
B3Building Class
R3AZoning
1,344 sfGross Floor Area
2Units
1 Open Violation 0 unresolved · 1 paperwork only ▸
Two family converted from one family · 3,000 sf lot · 0.45 FAR built · Flood zone X500
Locations of Work
ArchitectureStructuralPlumbing
Permit Issued — active, not yet Signed-off
Floor 2Under Construction14p · 1 filing · 17 docs
Floor 1Under Construction14p · 1 filing · 17 docs
CellarUnder Construction17p · 1 filing · 17 docs
1 job · most recent 07/13/2026
Air Conditioning Systems Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
07/13/2026Permit IssuedRISHON HOMES CORPAir Conditioning Systems, Heating Systems, Ventilation Systems
Cooling
Goodman GLXS4BA6010A 60,000 BTU · Condensing Unit ×1
GSXN403610A 36,000 BTU · Condensing Unit ×1
Heating
Goodman GM9S800603BN 60,000 BTU · Furnace ×1
GMVC961005CN 100,000 BTU · Furnace ×1
Ventilation
Hampton Bay 7114-01 50 CFM · Exhaust Fan ×5
Delta Breeze SMT150 150 CFM · Exhaust Fan ×2
1 job · most recent 07/13/2026
Gas Storm Water/Sanitary
FiledStatusContractorScope
07/13/2026Permit IssuedPLBG P & H INCGas, Storm, Water/Sanitary
1 job · most recent 07/13/2026
Steel Wood
FiledStatusContractorScope
07/13/2026Permit IssuedRISHON HOMES CORPSteel, Wood
1 job · most recent 03/20/2026
Fence
FiledStatusContractorScope
03/20/2026Permit IssuedRISHON HOMES CORPFence
Building Lifecycle
All (53)Filed (4)Permit Issued (4)Violation (1)Objection (14)Special Inspection (30)
09/21/2026
Permit issued — Foundation
Q01412617-I1-GC-CX
09/21/2026
Permit issued — General Construction
Q01412617-I1-FO-EA
09/17/2026
Permit issued — Plumbing
Q01412617-S1-PL
08/26/2026
Objection resolved — Resolved
08/17/2026
Objection raised — Energy
08/17/2026
Objection resolved — Resolved
07/15/2026
Objection resolved — Addressed
07/13/2026
Filed — Alteration CO
FILED HEREWITH MECHANICAL WORK TYPE IN CONJUNCTION WITH DOB NOW APPLICATION #Q01412617-I1
Q01412617-S2
07/13/2026
Objection resolved — Resolved
07/13/2026
Objection resolved — Addressed
07/13/2026
Objection resolved — Addressed
07/13/2026
Objection resolved — Addressed
07/06/2026
Objection raised — Energy
07/02/2026
Objection raised — Admin
07/02/2026
Objection raised — Zoning
07/02/2026
Objection raised — Other
07/02/2026
Objection raised — Zoning
07/02/2026
Objection raised — Other
06/08/2026
Filed — Alteration CO
FILED HEREWITH MECHANICAL WORK TYPE IN CONJUNCTION WITH DOB NOW APPLICATION #Q01412617-I1
Q01412617-S1
06/05/2026
Filed — Alteration CO
FILED HEREWITH MECHANICAL WORK TYPE IN CONJUNCTION WITH DOB NOW APPLICATION #Q01412617-I1
Q01412617-I1
06/05/2026
Special inspection requirement — Mechanical Systems
06/05/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
06/05/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
06/05/2026
Special inspection requirement — Final
06/05/2026
Special inspection requirement — Energy Code Compliance Inspections
06/05/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
06/05/2026
Special inspection requirement — Duct leakage testing, insulation and design
06/05/2026
Special inspection requirement — Maintenance information
06/05/2026
Special inspection requirement — HVAC-R and service water heating equipment
06/05/2026
Special inspection requirement — HVAC-R and service water heating system controls
06/05/2026
Special inspection requirement — Ventilation and air distribution system
06/04/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
06/04/2026
Special inspection requirement — Concrete - Cast-In-Place
06/04/2026
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
06/04/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
06/04/2026
Special inspection requirement — Masonry
06/04/2026
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
06/04/2026
Special inspection requirement — Structural Steel - High Strength Bolting
06/04/2026
Special inspection requirement — Subgrade Inspections
06/04/2026
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
06/04/2026
Special inspection requirement — Structural Steel - Details
06/04/2026
Special inspection requirement — Final
06/04/2026
Special inspection requirement — Footing and Foundation
06/04/2026
Special inspection requirement — Energy Code Compliance Inspections
06/04/2026
Special inspection requirement — Fire-Resistance Rated Construction
06/04/2026
Special inspection requirement — Structural Wood Frame
06/04/2026
Special inspection requirement — Fenestration areas
06/04/2026
Special inspection requirement — Air barrier - visual inspection
06/04/2026
Special inspection requirement — Fenestration air leakage
06/04/2026
Special inspection requirement — Insulation placement and R values
04/13/2026
Violation issued (ECB, open)
Construction
03/24/2026
Permit issued — Construction Fence
Q01375296-I1-FN
03/20/2026
Filed — Alteration
INSTALLATION OF TEMPORARY CONSTRUCTION FENCE IN CONJUNCTION WITH DOB NOW APPLICATION TO BE FILED. FENCE SHALL COMPLY WITH CHAPTER 33 OF THE NYC BUILDING CODE.
Q01375296-I1
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
135-223 STREET709/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NKM ENGINEERING PLLC307/13/2026
PETER CHO ARCHITECTS, PLLC103/20/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
RISHON HOMES CORPGeneral Contractor309/22/2026
PLBG P & H INCPlumbing109/18/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NKM ENGINEERING PLLC6244206/08/2026
TRIANGLE INSPECTION & TES7495106/08/2026
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWFoundationPermit IssuedRISHON HOMES CORP09/21/2026
DOB NOWGeneral ConstructionPermit IssuedRISHON HOMES CORP09/21/2026
DOB NOWPlumbingPermit IssuedPLBG P & H INC09/17/2026
DOB NOWConstruction FencePermit IssuedRISHON HOMES CORP03/24/2026
▾Special Inspection Requirements (DOB NOW) — 36
DateRequirementInspectorRole
06/05/2026Mechanical Systems—special
06/05/2026Fire-Resistant Penetrations and Joints—special
06/05/2026Structural Stability – Alterations of existing buildings—special
06/05/2026Final—progress
06/05/2026Energy Code Compliance Inspections—progress
06/05/2026HVAC-R and service water piping design and insulation—energy_progress
06/05/2026Duct leakage testing, insulation and design—energy_progress
06/05/2026Maintenance information—energy_progress
06/05/2026HVAC-R and service water heating equipment—energy_progress
06/05/2026HVAC-R and service water heating system controls—energy_progress
06/05/2026Ventilation and air distribution system—energy_progress
06/04/2026Structural Stability – Alterations of existing buildings—special
06/04/2026Concrete - Cast-In-Place—special
06/04/2026Excavations - Sheeting, Shoring, and Bracing—special
06/04/2026Fire-Resistant Penetrations and Joints—special
06/04/2026Masonry—special
06/04/2026Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation—special
06/04/2026Structural Steel - High Strength Bolting—special
06/04/2026Subgrade Inspections—special
06/04/2026Subsurface Investigations (Borings/Test Pits)—special
06/04/2026Structural Steel - Details—special
06/04/2026Final—progress
06/04/2026Footing and Foundation—progress
06/04/2026Energy Code Compliance Inspections—progress
06/04/2026Fire-Resistance Rated Construction—progress
Latest 25 of 36.
▾Documents — 18 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/29/2026Q01375296-I1Request digital key ↗
08/16/2026Q01412617-S2Request digital key ↗
08/14/2026Q01412617-S1Request digital key ↗
Showing 3 of 4 on file for this type
▸Zoning, Tax Lot & Property Records1
▸DOB NOWZD1: DOB Zoning Diagram1
08/14/2026Q01412617-I1Open ↗
▸Seals & Professional Certifications4
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/29/2026Q01375296-I1Open ↗
08/16/2026Q01412617-S1Open ↗
08/16/2026Q01412617-I1Open ↗
Showing 3 of 4 on file for this type
▸Safety & Tenant Protection1
▸DOB NOWStreet Tree Checklist1
08/14/2026Q01412617-I1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/16/2026Q01412617-S2Open ↗
08/14/2026Q01412617-S1Open ↗
08/14/2026Q01412617-I1Open ↗
▸Inspections & Test Reports1
▸DOB NOWSOIL REPORT1
08/14/2026Q01412617-I1Open ↗
▸Other Documents4
▸DOB NOWProperty Ownership Certification1
08/14/2026Q01412617-I1Open ↗
▸DOB NOWSite Survey: Initial1
08/14/2026Q01412617-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/14/2026Q01412617-I1Open ↗
▸DOB NOWPlot Diagram1
08/14/2026Q01412617-I1Open ↗