← Back
QUEENS
141-11 254 STREET
QUEENS · BIN 4288960
💬 Discuss this project
—Year Built
—Stories
—Building Class
—Zoning
—Gross Floor Area
—Units
5 Open Violations 1 unresolved · 4 paperwork only ▸FDNY Report ↗
Locations of Work
Architecture
Roof2p · 1 filing · 15 docs
Cellar3p · 1 filing · 15 docs
1 job · most recent 08/05/2026
Air Conditioning Systems Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
08/05/2026——Air Conditioning Systems, Heating Systems, Ventilation Systems
Cooling
Cooper & Hunter CH-N48LCU-230VO 55,000 BTU · Condensing Unit ×1
CH-N60LCU-230VO 60,000 BTU · Condensing Unit ×1
Heating
Cooper & Hunter CH-48AHU 55,000 BTU · Ahu ×1
CH-60AHU 60,000 BTU · Ahu ×1
Ventilation
Hampton Bay 7114-01 50 CFM · Exhaust Fan ×6
Delta Breeze SMT150 150 CFM · Kitchen Exhaust ×2
1 job · most recent 08/05/2026
Gas Storm Water/Sanitary
FiledStatusContractorScope
08/05/2026——Gas, Storm, Water/Sanitary
1 job · most recent 08/05/2026
Steel Wood
FiledStatusContractorScope
08/05/2026——Steel, Wood
1 job · most recent 08/05/2026
Fence
FiledStatusContractorScope
08/05/2026——Fence
Building Lifecycle
All (45)Filed (3)Violation (5)Objection (7)Special Inspection (30)
09/15/2026
Objection raised — Admin
09/15/2026
Objection raised — Zoning
09/15/2026
Objection raised — Zoning
09/15/2026
Objection raised — Cost
09/15/2026
Objection raised — Admin
09/15/2026
Objection raised — Structural
09/15/2026
Objection raised — Energy
08/05/2026
Filed — ALT-CO - New Building with Existing Elements to Remain
FILED HEREWITH PLUMBING WORK TYPE IN CONJUNCTION WITH APPLICATION #Q01424015-I1. FILED TO RESOLVE ECB VIOLATIONS.
Q01424015-I1
08/05/2026
Filed — ALT-CO - New Building with Existing Elements to Remain
FILED HEREWITH PLUMBING WORK TYPE IN CONJUNCTION WITH APPLICATION #Q01424015-I1. FILED TO RESOLVE ECB VIOLATIONS.
Q01424015-S1
08/05/2026
Filed — ALT-CO - New Building with Existing Elements to Remain
FILED HEREWITH PLUMBING WORK TYPE IN CONJUNCTION WITH APPLICATION #Q01424015-I1. FILED TO RESOLVE ECB VIOLATIONS.
Q01424015-S2
06/29/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
06/29/2026
Special inspection requirement — Mechanical Systems
06/29/2026
Special inspection requirement — Concrete - Cast-In-Place
06/29/2026
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
06/29/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
06/29/2026
Special inspection requirement — Heating Systems
06/29/2026
Special inspection requirement — Masonry
06/29/2026
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
06/29/2026
Special inspection requirement — Structural Steel - Details
06/29/2026
Special inspection requirement — Structural Steel - High Strength Bolting
06/29/2026
Special inspection requirement — Subgrade Inspections
06/29/2026
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
06/29/2026
Special inspection requirement — Final
06/29/2026
Special inspection requirement — Footing and Foundation
06/29/2026
Special inspection requirement — Energy Code Compliance Inspections
06/29/2026
Special inspection requirement — Fire-Resistance Rated Construction
06/29/2026
Special inspection requirement — Structural Wood Frame
06/29/2026
Special inspection requirement — Duct leakage testing, insulation and design
06/29/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
06/29/2026
Special inspection requirement — Fenestration areas
06/29/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
06/29/2026
Special inspection requirement — Electric vehicle service equipment requirements
06/29/2026
Special inspection requirement — HVAC-R and service water heating equipment
06/29/2026
Special inspection requirement — Metering
06/29/2026
Special inspection requirement — Interior lighting power
06/29/2026
Special inspection requirement — Insulation placement and R values
06/29/2026
Special inspection requirement — HVAC-R and service water heating system controls
06/29/2026
Special inspection requirement — Maintenance information
06/29/2026
Special inspection requirement — Fenestration air leakage
06/29/2026
Special inspection requirement — Permanent certificate
04/25/2008
Violation issued (DOB, open)
VW-VIOLATION WORK WITHOUT PERMIT - ACTIVE
04/25/2008
Violation issued (ECB, open)
Administrative
01/15/1998
Violation issued (ECB, open)
Quality of Life
01/15/1998
Violation issued (ECB, open)
Quality of Life
10/17/1997
Violation issued (ECB, open)
Construction
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
135-223 STREET109/01/2026
THE OWNER OF203/22/2026
OWNER OF PREMISES103/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NKM ENGINEERING PLLC208/05/2026
PETER CHO ARCHITECTS, PLLC108/05/2026
Nothing on file for this building.
▾Special Inspection Requirements (DOB NOW) — 33
DateRequirementInspectorRole
06/29/2026Structural Stability – Alterations of existing buildings—special
06/29/2026Mechanical Systems—special
06/29/2026Concrete - Cast-In-Place—special
06/29/2026Excavations - Sheeting, Shoring, and Bracing—special
06/29/2026Fire-Resistant Penetrations and Joints—special
06/29/2026Heating Systems—special
06/29/2026Masonry—special
06/29/2026Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation—special
06/29/2026Structural Steel - Details—special
06/29/2026Structural Steel - High Strength Bolting—special
06/29/2026Subgrade Inspections—special
06/29/2026Subsurface Investigations (Borings/Test Pits)—special
06/29/2026Final—progress
06/29/2026Footing and Foundation—progress
06/29/2026Energy Code Compliance Inspections—progress
06/29/2026Fire-Resistance Rated Construction—progress
06/29/2026Structural Wood Frame—progress
06/29/2026Duct leakage testing, insulation and design—energy_progress
06/29/2026Fenestration and door U-factor and product ratings—energy_progress
06/29/2026Fenestration areas—energy_progress
06/29/2026HVAC-R and service water piping design and insulation—energy_progress
06/29/2026Electric vehicle service equipment requirements—energy_progress
06/29/2026HVAC-R and service water heating equipment—energy_progress
06/29/2026Metering—energy_progress
06/29/2026Interior lighting power—energy_progress
Latest 25 of 33.
▾Documents — 25 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/16/2026Q01424015-S1Request digital key ↗
08/16/2026Q01424015-I1Request digital key ↗
08/16/2026Q01424015-S2Request digital key ↗
▸Applications & Permits2
▸BISPLAN / WORK APPROVAL APPLICATION2
04/14/2010410233974Open ↗
03/11/2009410233974Open ↗
▸Zoning, Tax Lot & Property Records2
▸DOB NOWZoning Exhibit form (1-5)1
09/28/2026Q01424015-I1Open ↗
▸DOB NOWZD1: DOB Zoning Diagram1
08/16/2026Q01424015-I1Open ↗
▸Seals & Professional Certifications3
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/16/2026Q01424015-S1Open ↗
08/16/2026Q01424015-S2Open ↗
08/16/2026Q01424015-I1Open ↗
▸Trade Schedules & Equipment1
▸BISSCHEDULE B - PLUMBING1
03/11/2009410233974Open ↗
▸Safety & Tenant Protection1
▸DOB NOWStreet Tree Checklist1
08/16/2026Q01424015-I1Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/16/2026Q01424015-S1Open ↗
08/16/2026Q01424015-I1Open ↗
08/16/2026Q01424015-S2Open ↗
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'1
03/11/2009410233974Open ↗
▸Inspections & Test Reports1
▸DOB NOWSOIL REPORT1
08/16/2026Q01424015-I1Open ↗
▸Approvals, Objections & Sign-offs3
▸BISSCHEDULE A - OCCUPANCY / USE2
03/11/2009410233974Open ↗
04/14/2010410233974Open ↗
▸BISADMINISTRATIVE OBJECTIONS1
03/11/2009410233974Open ↗
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1
03/11/2009410233974Open ↗
▸Other Documents4
▸BISPlot Diagram2
04/14/2010410233974Open ↗
03/11/2009410233974Open ↗
▸DOB NOWSite Survey: Initial1
08/16/2026Q01424015-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/16/2026Q01424015-I1Open ↗