| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 09/11/2026 | Permit Issued | 26 BONIM LLC | Heating and Air Conditioning Systems, Ventilation Systems | Heat / Cool Mitsubishi Electric MXZ-4C36NA3 34,400 BTU · Condensing Unit ×2 Ventilation Hampton Bay 7114-01 50 CFM · Exhaust Fan ×5 Delta Breeze SMT150 150 BTU · Exhaust Fan ×2 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 09/11/2026 | — | — | Gas, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 09/11/2026 | Permit Issued | 26 BONIM LLC | Wood |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 09/11/2026 | Permit Issued | 26 BONIM LLC | Fence |
| Owner | Filings | Most Recent |
|---|---|---|
| ZMIROT | 3 | 09/23/2026 |
| Firm | Filings | Most Recent |
|---|---|---|
| NKM ENGINEERING PLLC | 2 | 09/11/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| 26 BONIM LLC | General Contractor | 1 | 09/15/2026 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Construction Fence | Permit Issued | 26 BONIM LLC | 09/14/2026 |
| BIS | — | ISSUED | N/A | 11/24/1992 |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 09/10/2026 | Fire-Resistant Penetrations and Joints | — | special |
| 09/10/2026 | Energy Code Compliance Inspections | — | progress |
| 09/10/2026 | HVAC-R and service water heating system controls | — | energy_progress |
| 09/10/2026 | Maintenance information | — | energy_progress |
| 09/10/2026 | HVAC-R and service water heating equipment | — | energy_progress |
| 09/10/2026 | HVAC-R and service water piping design and insulation | — | energy_progress |
| 07/21/2026 | Subsurface Investigations (Borings/Test Pits) | — | special |
| 07/21/2026 | Final | — | progress |
| 07/21/2026 | Footing and Foundation | — | progress |
| 07/21/2026 | Energy Code Compliance Inspections | — | progress |
| 07/21/2026 | Fire-Resistance Rated Construction | — | progress |
| 07/21/2026 | Structural Wood Frame | — | progress |
| 07/21/2026 | Fenestration air leakage | — | energy_progress |
| 07/21/2026 | Permanent certificate | — | energy_progress |
| 07/21/2026 | Structural Stability – Alterations of existing buildings | — | special |
| 07/21/2026 | Insulation placement and R values | — | energy_progress |
| 07/21/2026 | Fenestration areas | — | energy_progress |
| 07/21/2026 | Electric vehicle service equipment requirements | — | energy_progress |
| 07/21/2026 | Metering | — | energy_progress |
| 07/21/2026 | Interior lighting power | — | energy_progress |
| 07/21/2026 | Air barrier - visual inspection | — | energy_progress |
| 07/21/2026 | Maintenance information | — | energy_progress |
| 07/21/2026 | Fenestration and door U-factor and product ratings | — | energy_progress |
| 07/21/2026 | Concrete - Cast-In-Place | — | special |
| 07/21/2026 | Excavations - Sheeting, Shoring, and Bracing | — | special |