← Back
Two family converted from one family
259-28 148 DRIVE
QUEENS · BIN 4291048
💬 Discuss this project
1960Year Built
2Stories
B3Building Class
R3XZoning
2,366 sfGross Floor Area
2Units
0 Open ViolationsFDNY Report ↗
Two family converted from one family · 3,900 sf lot · 0.61 FAR built · Flood zone X500
Locations of Work
ArchitectureElectricalMechanicalPlumbing
Floor 24p · 1 filing · 20 docs
Floor 14p · 1 filing · 20 docs
Cellar9p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
PARKSIDE REALTY GROUP1607/08/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
08/29/2023$1.3M—ORANGE DOOR REALTY GROUP LLC → Private party$554/sf building
11/22/2021$530K—— → —$224/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
CL ENGINEERING P.C.502/14/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
METRO DESIGN CONSULTANTS INC1003/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
PRECISION HOME DEV INCGeneral Contractor407/08/2026
INFINITI ESC PLUMBING CORPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
CL ENGINEERING P.C.6781402/14/2023
TRIANGLE INSPECTION & TES7495202/14/2023
Building Lifecycle
All (81)Filed (5)Permit Issued (3)Signed Off (2)Violation (3)Inspection (6)Objection (32)Special Inspection (30)
06/14/2023
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
04/07/2023
Signed off — Alteration CO
CONVERSION OF THE EXISTING ONE AND HALF STORY ONE-FAMILY BUILDING INTO A TWO-STORY TWO-FAMILY BUILDING AS SHOWN ON THE PLANS. PROPOSED VERTICAL AND HORIZONTAL ENLARGEMENT. INTERIOR RENOVATION. OBTAIN A NEW CERTIFICATE OF OCCUPANCY.
Q00674125-S3
03/20/2023
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
CHRISTIAN LOZADA
03/20/2023
Special inspection requirement — Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention Facilities
Rajasekhar Sakhamuri
03/20/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
CHRISTIAN LOZADA
03/20/2023
Special inspection requirement — Energy Code Compliance Inspections
CHRISTIAN LOZADA
03/20/2023
Special inspection requirement — Maintenance information
CHRISTIAN LOZADA
03/20/2023
Special inspection requirement — HVAC-R and service water heating system controls
CHRISTIAN LOZADA
03/20/2023
Special inspection requirement — HVAC-R and service water heating equipment
CHRISTIAN LOZADA
03/20/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
CHRISTIAN LOZADA
03/02/2023
Signed off — Alteration CO
CONVERSION OF THE EXISTING ONE AND HALF STORY ONE-FAMILY BUILDING INTO A TWO-STORY TWO-FAMILY BUILDING AS SHOWN ON THE PLANS. PROPOSED VERTICAL AND HORIZONTAL ENLARGEMENT. INTERIOR RENOVATION. OBTAIN A NEW CERTIFICATE OF OCCUPANCY.
Q00674125-S1
03/02/2023
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
02/27/2023
Special inspection requirement — Structural Steel - High Strength Bolting
CHRISTIAN LOZADA
02/27/2023
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
CHRISTIAN LOZADA
02/27/2023
Special inspection requirement — Masonry
CHRISTIAN LOZADA
02/27/2023
Special inspection requirement — Structural Stability – Alterations of existing buildings
CHRISTIAN LOZADA
02/27/2023
Special inspection requirement — Subgrade Inspections
CHRISTIAN LOZADA
02/27/2023
Special inspection requirement — Structural Wood Frame
CHRISTIAN LOZADA
02/27/2023
Special inspection requirement — Energy Code Compliance Inspections
CHRISTIAN LOZADA
02/27/2023
Special inspection requirement — Final
CHRISTIAN LOZADA
02/27/2023
Special inspection requirement — Fire-Resistance Rated Construction
CHRISTIAN LOZADA
02/27/2023
Special inspection requirement — Duct leakage testing, insulation and design
CHRISTIAN LOZADA
02/27/2023
Special inspection requirement — HVAC-R and service water heating equipment
CHRISTIAN LOZADA
02/27/2023
Special inspection requirement — Ventilation and air distribution system
CHRISTIAN LOZADA
02/27/2023
Special inspection requirement — Interior lighting power
CHRISTIAN LOZADA
02/27/2023
Special inspection requirement — Fenestration air leakage
CHRISTIAN LOZADA
02/27/2023
Special inspection requirement — Fenestration and door U-factor and product ratings
CHRISTIAN LOZADA
02/27/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
CHRISTIAN LOZADA
02/27/2023
Special inspection requirement — HVAC-R and service water heating system controls
CHRISTIAN LOZADA
02/27/2023
Special inspection requirement — Electric vehicle service equipment requirements
CHRISTIAN LOZADA
02/27/2023
Special inspection requirement — Permanent certificate
CHRISTIAN LOZADA
02/27/2023
Special inspection requirement — Insulation placement and R values
CHRISTIAN LOZADA
02/27/2023
Special inspection requirement — Metering
CHRISTIAN LOZADA
02/27/2023
Special inspection requirement — Maintenance information
CHRISTIAN LOZADA
02/23/2023
Objection resolved — Addressed
02/23/2023
Objection resolved — Addressed
02/21/2023
Objection raised — Zoning
02/21/2023
Objection raised — Zoning
02/14/2023
Filed — Alteration CO
CONVERSION OF THE EXISTING ONE AND HALF STORY ONE-FAMILY BUILDING INTO A TWO-STORY TWO-FAMILY BUILDING AS SHOWN ON THE PLANS. PROPOSED VERTICAL AND HORIZONTAL ENLARGEMENT. INTERIOR RENOVATION. OBTAIN A NEW CERTIFICATE OF OCCUPANCY.
Q00674125-P1
02/14/2023
Filed — Alteration CO
CONVERSION OF THE EXISTING ONE AND HALF STORY ONE-FAMILY BUILDING INTO A TWO-STORY TWO-FAMILY BUILDING AS SHOWN ON THE PLANS. PROPOSED VERTICAL AND HORIZONTAL ENLARGEMENT. INTERIOR RENOVATION. OBTAIN A NEW CERTIFICATE OF OCCUPANCY.
Q00674125-P2
01/13/2023
Violation issued (ECB, closed)
Unknown
09/27/2022
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
09/27/2022
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
09/27/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
09/27/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
09/22/2022
Permit issued — Plumbing
Q00674125-S3-PL
08/03/2022
Violation issued (ECB, closed)
Construction
08/03/2022
Violation issued (ECB, closed)
Site Safety
07/29/2022
Filed — Alteration CO
CONVERSION OF THE EXISTING ONE AND HALF STORY ONE-FAMILY BUILDING INTO A TWO-STORY TWO-FAMILY BUILDING AS SHOWN ON THE PLANS. PROPOSED VERTICAL AND HORIZONTAL ENLARGEMENT. INTERIOR RENOVATION. OBTAIN A NEW CERTIFICATE OF OCCUPANCY.
Q00674125-S3
07/29/2022
Permit issued — Mechanical Systems
Q00674125-I1-GC-CX
07/27/2022
Permit issued — Construction Fence
Q00674125-S1-FN
04/11/2022
Objection raised — Structural
04/11/2022
Objection resolved — Addressed
03/21/2022
Objection raised — Scope
03/21/2022
Objection resolved — Addressed
03/21/2022
Objection raised — Fire_Protection
03/21/2022
Objection resolved — Addressed
03/21/2022
Objection raised — Scope
03/21/2022
Objection resolved — Addressed
03/21/2022
Objection raised — Scope
Latest 60 of 81 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offINFINITI ESC PLUMBING COR09/22/2022
DOB NOWMechanical SystemsPermit IssuedPRECISION HOME DEV INC07/29/2022
DOB NOWConstruction FenceSigned-offPRECISION HOME DEV INC07/27/2022
1 project · most recent 02/14/2023
Air Conditioning Systems Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
02/14/2023Permit IssuedPRECISION HOME DEV INCAir Conditioning Systems, Heating Systems, Ventilation Systems
Cooling
Goodman GSX130481 48,000 BTU · Condensing Unit ×2
GSX130601 60,000 BTU · Condensing Unit ×2
Heating
Goodman GM9S920804CN 80,000 BTU · Furnace ×2
GM9S921004CN 100,000 BTU · Furnace ×2
Ventilation
Hampton Bay 7114-01 50 CFM · Exhaust Fan ×10
Delta Breeze SMT150 150 CFM · Exhaust Fan ×4
1 project · most recent 02/14/2023
Gas Storm Water/Sanitary
FiledStatusContractorScope
02/14/2023Signed-offINFINITI ESC PLUMBING CORGas, Storm, Water/Sanitary
1 project · most recent 08/15/2022
General Wiring
FiledStatusContractorScope
08/15/2022CompletePOWER SURGE ELECTRIC, INCGeneral Wiring
1 project · most recent 02/14/2023
Steel Wood
FiledStatusContractorScope
02/14/2023Signed-offINFINITI ESC PLUMBING CORSteel, Wood
1 project · most recent 02/14/2023
Earthwork
FiledStatusContractorScope
02/14/2023Signed-offINFINITI ESC PLUMBING COREarthwork
▾Field Inspections (DOB CAP) — 6
DateTypeResultReport
06/14/2023Pass-Final CND-Occupancy InspectionPassView ↗
03/02/2023Pass-Final CND-Occupancy InspectionPassView ↗
09/27/2022Certified Gas-Gas-Piping-RoughingCertifiedView ↗
09/27/2022Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
09/27/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
09/27/2022Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 48
DateRequirementInspectorRole
03/20/2023Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationCHRISTIAN LOZADAspecial
03/20/2023Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention FacilitiesRajasekhar Sakhamurispecial
03/20/2023Fire-Resistant Penetrations and JointsCHRISTIAN LOZADAspecial
03/20/2023Energy Code Compliance InspectionsCHRISTIAN LOZADAprogress
03/20/2023Maintenance informationCHRISTIAN LOZADAenergy_progress
03/20/2023HVAC-R and service water heating system controlsCHRISTIAN LOZADAenergy_progress
03/20/2023HVAC-R and service water heating equipmentCHRISTIAN LOZADAenergy_progress
03/20/2023HVAC-R and service water piping design and insulationCHRISTIAN LOZADAenergy_progress
02/27/2023Structural Steel - High Strength BoltingCHRISTIAN LOZADAspecial
02/27/2023Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationCHRISTIAN LOZADAspecial
02/27/2023MasonryCHRISTIAN LOZADAspecial
02/27/2023Structural Stability – Alterations of existing buildingsCHRISTIAN LOZADAspecial
02/27/2023Subgrade InspectionsCHRISTIAN LOZADAspecial
02/27/2023Structural Wood FrameCHRISTIAN LOZADAprogress
02/27/2023Energy Code Compliance InspectionsCHRISTIAN LOZADAprogress
02/27/2023FinalCHRISTIAN LOZADAprogress
02/27/2023Fire-Resistance Rated ConstructionCHRISTIAN LOZADAprogress
02/27/2023Duct leakage testing, insulation and designCHRISTIAN LOZADAenergy_progress
02/27/2023HVAC-R and service water heating equipmentCHRISTIAN LOZADAenergy_progress
02/27/2023Ventilation and air distribution systemCHRISTIAN LOZADAenergy_progress
02/27/2023Interior lighting powerCHRISTIAN LOZADAenergy_progress
02/27/2023Fenestration air leakageCHRISTIAN LOZADAenergy_progress
02/27/2023Fenestration and door U-factor and product ratingsCHRISTIAN LOZADAenergy_progress
02/27/2023HVAC-R and service water piping design and insulationCHRISTIAN LOZADAenergy_progress
02/27/2023HVAC-R and service water heating system controlsCHRISTIAN LOZADAenergy_progress
Latest 25 of 48.
▾Documents — 50 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch5
08/25/2026Q00674125-S1Request digital key ↗
08/25/2026Q00674125-S3Request digital key ↗
08/25/2026Q00674125-P1Request digital key ↗
Showing 3 of 5 on file for this type
▸Zoning, Tax Lot & Property Records3
▸DOB NOWZD1: DOB Zoning Diagram2
08/13/2026Q00674125-I1Open ↗
08/13/2026Q00674125-P1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026Q00674125-I1Open ↗
▸Seals & Professional Certifications20
▸DOB NOWSpecial Inspector Seal & Signature9
09/19/2026Q00674125-P2Open ↗
09/19/2026Q00674125-P2Open ↗
08/25/2026Q00674125-S3Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWProgress Inspector Seal & Signature6
09/19/2026Q00674125-P2Open ↗
09/19/2026Q00674125-P2Open ↗
08/25/2026Q00674125-S3Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/13/2026Q00674125-I1Open ↗
08/13/2026Q00674125-S3Open ↗
08/13/2026Q00674125-S1Open ↗
Showing 3 of 5 on file for this type
▸Safety & Tenant Protection2
▸DOB NOWStreet Tree Checklist2
08/13/2026Q00674125-I1Open ↗
08/13/2026Q00674125-P1Open ↗
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/13/2026Q00674125-S1Open ↗
08/13/2026Q00674125-P2Open ↗
08/13/2026Q00674125-I1Open ↗
Showing 3 of 5 on file for this type
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis1
08/13/2026Q00674125-I1Open ↗
▸Inspections & Test Reports4
▸DOB NOWSOIL REPORT2
08/13/2026Q00674125-I1Open ↗
08/13/2026Q00674125-P1Open ↗
▸DOB NOWTR4 Plot Diagram1
08/13/2026Q00674125-I1Open ↗
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026Q00674125-I1Open ↗
▸Other Documents10
▸DOB NOWSite Survey: Initial2
08/13/2026Q00674125-I1Open ↗
08/13/2026Q00674125-P1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone2
08/13/2026Q00674125-P1Open ↗
08/13/2026Q00674125-I1Open ↗
▸DOB NOWPlot Diagram2
08/13/2026Q00674125-P1Open ↗
08/13/2026Q00674125-I1Open ↗
▸DOB NOWProperty Ownership Certification2
08/13/2026Q00674125-I1Open ↗
08/13/2026Q00674125-P1Open ↗
▸DOB NOWFinal Survey1
08/13/2026Q00674125-I1Open ↗
▸DOB NOWAdjoining Owners Notification1
08/13/2026Q00674125-I1Open ↗