← Back
Two family converted from one family
259-64 148 DRIVE
QUEENS · BIN 4291057
💬 Discuss this project
1950Year Built
2Stories
B3Building Class
R3XZoning
2,510 sfGross Floor Area
2Units
0 Open ViolationsFDNY Report ↗
Two family converted from one family · 4,000 sf lot · 0.63 FAR built · Flood zone X500
Locations of Work
ArchitectureStructuralElectricalPlumbingFire Protection
Permit Issued — active, not yet Signed-off
Floor 2Under Construction33p · 1 filing · 20 docs
Floor 1Under Construction32p · 1 filing · 20 docs
CellarUnder Construction31p · 1 filing · 20 docs
1 job · most recent 05/14/2026
Sprinkler System
FiledStatusContractorScope
05/14/2026——Sprinkler System
1 job · most recent 05/14/2026
Gas Storm Water/Sanitary
FiledStatusContractorScope
05/14/2026Permit IssuedBT'S PLUMBING AND HEATINGGas, Storm, Water/Sanitary
1 job · most recent 08/22/2024
General Wiring
FiledStatusContractorScope
08/22/2024Permit IssuedJOSEPH WEINSTEIN ELECTRICGeneral Wiring
1 job · most recent 05/14/2026
Fence
FiledStatusContractorScope
05/14/2026Permit IssuedBT'S PLUMBING AND HEATINGFence
Building Lifecycle
All (106)Filed (8)Permit Issued (4)Signed Off (1)Violation (3)Inspection (8)Objection (52)Special Inspection (30)
08/03/2026
Signed off — ALT-CO - New Building with Existing Elements to Remain
Enlargement and conversion to 2-family dwelling as per submitted drawings. Filing to obtain a new certificate of occupancy. No change in use and egress.
Q08047737-S2
06/02/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
05/18/2026
Special inspection requirement — Permanent certificate
GLEN LANGER
05/18/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
GLEN LANGER
05/18/2026
Special inspection requirement — Metering
GLEN LANGER
05/18/2026
Special inspection requirement — HVAC-R and service water heating equipment
GLEN LANGER
05/18/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
GLEN LANGER
05/18/2026
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
GLEN LANGER
05/18/2026
Special inspection requirement — Maintenance information
GLEN LANGER
05/18/2026
Special inspection requirement — HVAC-R and service water heating system controls
GLEN LANGER
05/14/2026
Filed — ALT-CO - New Building with Existing Elements to Remain
Enlargement and conversion to 2-family dwelling as per submitted drawings. Filing to obtain a new certificate of occupancy. No change in use and egress.
Q08047737-P6
05/07/2026
Special inspection requirement — Maintenance information
GLEN LANGER
05/07/2026
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
GLEN LANGER
05/07/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
GLEN LANGER
05/07/2026
Special inspection requirement — Metering
GLEN LANGER
05/07/2026
Special inspection requirement — HVAC-R and service water heating system controls
GLEN LANGER
05/07/2026
Special inspection requirement — Permanent certificate
GLEN LANGER
05/07/2026
Special inspection requirement — HVAC-R and service water heating equipment
GLEN LANGER
05/07/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
GLEN LANGER
03/25/2026
Filed — ALT-CO - New Building with Existing Elements to Remain
Enlargement and conversion to 2-family dwelling as per submitted drawings. Filing to obtain a new certificate of occupancy. No change in use and egress.
Q08047737-P4
02/20/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
02/02/2026
Special inspection requirement — Maintenance information
GLEN LANGER
02/02/2026
Special inspection requirement — Permanent certificate
GLEN LANGER
02/02/2026
Special inspection requirement — Metering
GLEN LANGER
02/02/2026
Special inspection requirement — HVAC-R and service water heating equipment
GLEN LANGER
02/02/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
GLEN LANGER
02/02/2026
Special inspection requirement — HVAC-R and service water heating system controls
GLEN LANGER
02/02/2026
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
GLEN LANGER
02/02/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
GLEN LANGER
01/22/2026
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
01/22/2026
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
01/22/2026
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
01/22/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
01/22/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
12/03/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
11/07/2025
Permit issued — Plumbing
Q08047737-S1-PL
08/26/2025
Special inspection requirement — Sprinkler Systems
08/12/2025
Objection resolved — Addressed
07/15/2025
Objection resolved — Addressed
07/14/2025
Objection raised — Scope
07/14/2025
Objection raised — Cost
06/24/2025
Filed — ALT-CO - New Building with Existing Elements to Remain
Enlargement and conversion to 2-family dwelling as per submitted drawings. Filing to obtain a new certificate of occupancy. No change in use and egress.
Q08047737-P3
04/30/2025
Special inspection requirement — Sprinkler Systems
05/30/2024
Special inspection requirement — Permanent certificate
GLEN LANGER
05/30/2024
Special inspection requirement — Energy Code Compliance Inspections
GLEN LANGER
05/30/2024
Special inspection requirement — Fenestration and door U-factor and product ratings
GLEN LANGER
05/30/2024
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
GLEN LANGER
05/21/2024
Objection resolved — Addressed
05/20/2024
Objection raised — Scope
05/13/2024
Filed — ALT-CO - New Building with Existing Elements to Remain
Enlargement and conversion to 2-family dwelling as per submitted drawings. Filing to obtain a new certificate of occupancy. No change in use and egress.
Q08047737-P2
05/07/2024
Violation issued (ECB, closed)
Construction
04/24/2024
Permit issued — Plumbing
Q08047737-S1-PL
04/23/2024
Permit issued — General Construction
Q08047737-I1-GC
03/20/2024
Objection resolved — Addressed
03/06/2024
Violation issued (ECB, closed)
Construction
02/27/2024
Objection resolved — Addressed
02/09/2024
Permit issued — Construction Fence
Q08047737-S2-FN
01/24/2024
Objection resolved — Addressed
01/24/2024
Objection resolved — Addressed
01/24/2024
Objection resolved — Addressed
Latest 60 of 106 events.
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
SOUTHERN CONSULTING ENGINEERING PC805/14/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
JARED ASSOCIATE CONSULTING1203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
L&L CONSTRUCTION DEVELOPGeneral Contractor303/21/2026
UMOJA USA LLCGeneral Contractor107/08/2026
BT'S PLUMBING AND HEATINGPlumbing107/08/2026
M & M PIPING AND HEATINGPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
S&S CONCRETE & SOIL TESTI1008505/14/2026
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedBT'S PLUMBING AND HEATING11/07/2025
DOB NOWPlumbingPermit IssuedM & M PIPING AND HEATING04/24/2024
DOB NOWGeneral ConstructionPermit IssuedL&L CONSTRUCTION DEVELOP04/23/2024
DOB NOWConstruction FenceSigned-offUMOJA USA LLC02/09/2024
BISOTISSUEDTOM PETERSEN ARCHITECT, LLC09/09/2014
▾Field Inspections (DOB CAP) — 8
DateTypeResultReport
06/02/2026Pass-Final CND-Occupancy InspectionPassView ↗
02/20/2026Pass-Final CND-Occupancy InspectionPassView ↗
01/22/2026Certified Gas-Gas-Piping-RoughingCertifiedView ↗
01/22/2026Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
01/22/2026Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
01/22/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
01/22/2026Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
12/03/2025Pass-Final CND-Occupancy InspectionPassView ↗
▾Special Inspection Requirements (DOB NOW) — 64
DateRequirementInspectorRole
05/18/2026Maintenance informationGLEN LANGERenergy_progress
05/18/2026Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationGLEN LANGERspecial
05/18/2026Fire-Resistant Penetrations and JointsGLEN LANGERspecial
05/18/2026HVAC-R and service water piping design and insulationGLEN LANGERenergy_progress
05/18/2026MeteringGLEN LANGERenergy_progress
05/18/2026HVAC-R and service water heating system controlsGLEN LANGERenergy_progress
05/18/2026HVAC-R and service water heating equipmentGLEN LANGERenergy_progress
05/18/2026Permanent certificateGLEN LANGERenergy_progress
05/07/2026HVAC-R and service water heating system controlsGLEN LANGERenergy_progress
05/07/2026Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationGLEN LANGERspecial
05/07/2026Fire-Resistant Penetrations and JointsGLEN LANGERspecial
05/07/2026Permanent certificateGLEN LANGERenergy_progress
05/07/2026Maintenance informationGLEN LANGERenergy_progress
05/07/2026HVAC-R and service water heating equipmentGLEN LANGERenergy_progress
05/07/2026HVAC-R and service water piping design and insulationGLEN LANGERenergy_progress
05/07/2026MeteringGLEN LANGERenergy_progress
02/02/2026Permanent certificateGLEN LANGERenergy_progress
02/02/2026MeteringGLEN LANGERenergy_progress
02/02/2026Maintenance informationGLEN LANGERenergy_progress
02/02/2026Fire-Resistant Penetrations and JointsGLEN LANGERspecial
02/02/2026Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationGLEN LANGERspecial
02/02/2026HVAC-R and service water heating system controlsGLEN LANGERenergy_progress
02/02/2026HVAC-R and service water piping design and insulationGLEN LANGERenergy_progress
02/02/2026HVAC-R and service water heating equipmentGLEN LANGERenergy_progress
08/26/2025Sprinkler Systems—special
Latest 25 of 64.
▾Documents — 71 on file (BIS + DOB NOW)
▸Plans & Drawings9
▸DOB NOWPlans/Sketch9
08/17/2026Q08047737-P4Request digital key ↗
08/17/2026Q08047737-S3Request digital key ↗
08/17/2026Q08047737-S2Request digital key ↗
Showing 3 of 9 on file for this type
▸Applications & Permits3
▸BISPLAN / WORK APPROVAL APPLICATION1
09/05/2014440167061Open ↗
▸BISWORK PERMIT APPLICATION1
09/05/2014440167061Open ↗
▸BISNon-Directive 14 Construction Sign Off Including Sign Applications1
04/14/2016440167061Open ↗
▸Zoning, Tax Lot & Property Records4
▸DOB NOWZD1: DOB Zoning Diagram3
08/13/2026Q08047737-I1Open ↗
08/13/2026Q08047737-P2Open ↗
08/13/2026Q08047737-P5Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026Q08047737-I1Open ↗
▸Seals & Professional Certifications30
▸DOB NOWProgress Inspector Seal & Signature12
08/31/2026Q08047737-P5Open ↗
08/31/2026Q08047737-P5Open ↗
08/31/2026Q08047737-P5Open ↗
Showing 3 of 12 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature9
08/17/2026Q08047737-P3Open ↗
08/17/2026Q08047737-P2Open ↗
08/17/2026Q08047737-S3Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature6
08/31/2026Q08047737-P5Open ↗
08/28/2026Q08047737-I1Open ↗
08/27/2026Q08047737-P4Open ↗
Showing 3 of 6 on file for this type
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
09/05/2014440167061Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
09/05/2014440167061Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
09/05/2014440167061Open ↗
▸Safety & Tenant Protection1
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026Q08047737-I1Open ↗
▸Environmental & Asbestos9
▸DOB NOWDEP ACP-5: Asbestos Assessment Report9
08/17/2026Q08047737-S3Open ↗
08/17/2026Q08047737-S2Open ↗
08/17/2026Q08047737-S1Open ↗
Showing 3 of 9 on file for this type
▸Approvals, Objections & Sign-offs2
▸BISLETTERS - SUPPORTING DOCUMENTATION1
04/14/2016440167061Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
04/14/2016440167061Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
04/14/2016440167061Open ↗
09/05/2014440167061Open ↗
▸Filing & Intake Forms2
▸BISADDITIONAL INFORMATION1
11/02/2015440167061Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
09/05/2014440167061Open ↗
▸Other Documents9
▸DOB NOWSite Survey: Initial3
08/13/2026Q08047737-P5Open ↗
08/13/2026Q08047737-P2Open ↗
08/13/2026Q08047737-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone3
08/13/2026Q08047737-P2Open ↗
08/13/2026Q08047737-P5Open ↗
08/13/2026Q08047737-I1Open ↗
▸DOB NOWProperty Ownership Certification3
08/17/2026Q08047737-P5Open ↗
08/15/2026Q08047737-I1Open ↗
08/14/2026Q08047737-P2Open ↗