← Back
One story - permanent living quarter
158-11 98 STREET
QUEENS · BIN 4295165
💬 Discuss this project
1920Year Built
1.5Stories
A2Building Class
R3XZoning
1,474 sfGross Floor Area
1Units
1 Open Violation ▸FDNY Report ↗
One story - permanent living quarter · 3,000 sf lot · 0.49 FAR built · Flood zone AE
Locations of Work
ArchitectureMechanicalPlumbing
Permit Issued — active, not yet Signed-off
Floor 2Under Construction13p · 1 filing · 20 docs
Floor 1Under Construction2p · 1 filing · 20 docs
BasementUnder Construction2p · 1 filing · 20 docs
1 job · most recent 08/07/2026
Air Conditioning Systems Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
08/07/2026Permit IssuedLW CONTRACTING INCAir Conditioning Systems, Heating Systems, Ventilation Systems
Cooling
Daikin 5MXM48AVJU9 46,000 BTU · Heat Pump Outdoor ×1
Mitsubishi Electric MUZ-WR24NA 38,100 BTU · Heat Pump Outdoor ×1
Heating
Daikin 5MXM48AVJU9 48,500 BTU · Heat Pump Outdoor ×1
5MXS48TVJU 48,500 BTU ×1
Mitsubishi Electric MUZ-WR24NA 38,100 BTU ×1
Ventilation
Broan QTXE110 110 CFM · Exhaust Fan ×6
1 job · most recent 08/07/2026
Gas Water/Sanitary
FiledStatusContractorScope
08/07/2026Permit IssuedMAXWELL PLUMB MECH. CORPGas, Water/Sanitary
1 job · most recent 12/24/2025
General Wiring
FiledStatusContractorScope
12/24/2025CompleteJOSEPH WEINSTEIN ELECTRICGeneral Wiring
1 job · most recent 08/07/2026
Fence
FiledStatusContractorScope
08/07/2026Permit IssuedLW CONTRACTING INCFence
Building Lifecycle
All (63)Filed (5)Permit Issued (6)Signed Off (1)Violation (2)Inspection (7)Objection (12)Special Inspection (30)
09/14/2026
Signed off — Alteration CO
HEREWITH FILE ALTERATION TO ERECT TEMPORARY CONSTRUCTION PLY WOOD FENCE IN CONJUNCTION WITH ALTERATION APPLICATION Q01204044-S1
Q01204044-S1
09/14/2026
Permit issued — General Construction
Q01204044-I1-MS
08/07/2026
Filed — Alteration CO
HEREWITH FILE ALTERATION TO ERECT TEMPORARY CONSTRUCTION PLY WOOD FENCE IN CONJUNCTION WITH ALTERATION APPLICATION Q01204044-S1
Q01204044-P2
08/06/2026
Objection resolved — Resolved
08/06/2026
Objection resolved — Resolved
08/06/2026
Objection resolved — Resolved
07/22/2026
Objection raised — Other
07/22/2026
Objection raised — Other
07/22/2026
Objection raised — Other
07/14/2026
Filed — Alteration CO
HEREWITH FILE ALTERATION TO ERECT TEMPORARY CONSTRUCTION PLY WOOD FENCE IN CONJUNCTION WITH ALTERATION APPLICATION Q01204044-S1
Q01204044-P1
07/13/2026
Special inspection requirement — Exterior Insulation and Finish Systems (EIFS)
SYED RIZVI
07/13/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
SYED RIZVI
07/13/2026
Special inspection requirement — Mechanical Systems
SYED RIZVI
07/13/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
SYED RIZVI
07/13/2026
Special inspection requirement — Energy Code Compliance Inspections
SYED RIZVI
07/13/2026
Special inspection requirement — Final
HAYM GROSS
07/13/2026
Special inspection requirement — Fire-Resistance Rated Construction
SYED RIZVI
07/13/2026
Special inspection requirement — Fenestration areas
SYED RIZVI
07/13/2026
Special inspection requirement — Maintenance information
SYED RIZVI
07/13/2026
Special inspection requirement — HVAC-R and service water heating equipment
SYED RIZVI
07/13/2026
Special inspection requirement — HVAC-R and service water heating system controls
SYED RIZVI
07/13/2026
Special inspection requirement — Air barrier - visual inspection
SYED RIZVI
07/13/2026
Special inspection requirement — Insulation placement and R values
SYED RIZVI
07/13/2026
Special inspection requirement — Permanent certificate
SYED RIZVI
07/13/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
SYED RIZVI
07/13/2026
Special inspection requirement — Fenestration air leakage
SYED RIZVI
07/13/2026
Special inspection requirement — Interior lighting power
SYED RIZVI
07/13/2026
Special inspection requirement — Air barrier — testing
SYED RIZVI
07/13/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
SYED RIZVI
05/12/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
04/30/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
04/22/2026
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
04/17/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
04/10/2026
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
04/03/2026
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
02/02/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
01/23/2026
Permit issued — Plumbing
Q01204044-S2-PL
11/17/2025
Permit issued — Construction Fence
Q01204044-S1-FN
11/07/2025
Permit issued — General Construction
Q01204044-I1-GC
07/17/2025
Objection resolved — Addressed
07/14/2025
Objection resolved — Addressed
06/23/2025
Objection raised — Cost
06/23/2025
Objection raised — Energy
06/18/2025
Permit issued — Construction Fence
Q01204044-S1-FN
06/12/2025
Filed — Alteration CO
HEREWITH FILE ALTERATION TO ERECT TEMPORARY CONSTRUCTION PLY WOOD FENCE IN CONJUNCTION WITH ALTERATION APPLICATION Q01204044-S1
Q01204044-S2
06/11/2025
Filed — Alteration CO
HEREWITH FILE ALTERATION TO ERECT TEMPORARY CONSTRUCTION PLY WOOD FENCE IN CONJUNCTION WITH ALTERATION APPLICATION Q01204044-S1
Q01204044-S1
06/11/2025
Permit issued — Mechanical Systems
Q01204044-I1-GC
05/28/2025
Objection resolved — Addressed
05/12/2025
Special inspection requirement — Permanent certificate
SYED RIZVI
05/12/2025
Special inspection requirement — Maintenance information
SYED RIZVI
04/17/2025
Objection raised — Admin
04/09/2025
Filed — Alteration CO
HEREWITH FILE ALTERATION TO ERECT TEMPORARY CONSTRUCTION PLY WOOD FENCE IN CONJUNCTION WITH ALTERATION APPLICATION Q01204044-S1
Q01204044-I1
04/08/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
SYED RIZVI
04/08/2025
Special inspection requirement — HVAC-R and service water heating equipment
SYED RIZVI
04/08/2025
Special inspection requirement — HVAC-R and service water heating system controls
SYED RIZVI
04/07/2025
Special inspection requirement — Energy Code Compliance Inspections
SYED RIZVI
04/07/2025
Special inspection requirement — Fire-Resistance Rated Construction
SYED RIZVI
04/07/2025
Special inspection requirement — Fenestration areas
SYED RIZVI
04/07/2025
Special inspection requirement — Exterior Insulation and Finish Systems (EIFS)
SYED RIZVI
04/07/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
SYED RIZVI
Latest 60 of 63 events.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
LW CONTRACTING1009/15/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
GERALD CALIENDO ARCHITECTS508/07/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
GERALD J. CALIENDO R.A., P.C.303/21/2026
GERALD J CALIENDO R A P C303/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
LW CONTRACTING INCGeneral Contractor709/15/2026
JOSEPH WEINSTEIN ELECTRICElectrical103/22/2026
MAXWELL PLUMB MECH. CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
RIKE TECH ASSOCIATES LLC2965408/07/2026
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedLW CONTRACTING INC09/14/2026
DOB NOWPlumbingPermit IssuedMAXWELL PLUMB MECH. CORP01/23/2026
DOB NOWConstruction FenceSigned-offLW CONTRACTING INC11/17/2025
DOB NOWGeneral ConstructionPermit IssuedLW CONTRACTING INC11/07/2025
DOB NOWConstruction FenceSigned-offLW CONTRACTING INC06/18/2025
DOB NOWMechanical SystemsPermit IssuedLW CONTRACTING INC06/11/2025
BIS—ISSUEDLW CONTRACTING INC07/07/2016
BISOTISSUEDNYC DEV & CON LLC05/11/2007
▾Field Inspections (DOB CAP) — 7
DateTypeResultReport
05/12/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
04/30/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
04/22/2026Certified Gas-Gas-Piping-RoughingCertifiedView ↗
04/17/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
04/10/2026Pass-Final General Construction Non-Directive 14PassView ↗
04/03/2026Fail-Final General Construction Non-Directive 14FailView ↗
02/02/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 38
DateRequirementInspectorRole
07/13/2026Exterior Insulation and Finish Systems (EIFS)SYED RIZVIspecial
07/13/2026Fire-Resistant Penetrations and JointsSYED RIZVIspecial
07/13/2026Mechanical SystemsSYED RIZVIspecial
07/13/2026Structural Stability – Alterations of existing buildingsSYED RIZVIspecial
07/13/2026Energy Code Compliance InspectionsSYED RIZVIprogress
07/13/2026FinalHAYM GROSSprogress
07/13/2026Fire-Resistance Rated ConstructionSYED RIZVIprogress
07/13/2026Fenestration areasSYED RIZVIenergy_progress
07/13/2026Maintenance informationSYED RIZVIenergy_progress
07/13/2026HVAC-R and service water heating equipmentSYED RIZVIenergy_progress
07/13/2026HVAC-R and service water heating system controlsSYED RIZVIenergy_progress
07/13/2026Air barrier - visual inspectionSYED RIZVIenergy_progress
07/13/2026Insulation placement and R valuesSYED RIZVIenergy_progress
07/13/2026Permanent certificateSYED RIZVIenergy_progress
07/13/2026HVAC-R and service water piping design and insulationSYED RIZVIenergy_progress
07/13/2026Fenestration air leakageSYED RIZVIenergy_progress
07/13/2026Interior lighting powerSYED RIZVIenergy_progress
07/13/2026Air barrier — testing SYED RIZVIenergy_progress
07/13/2026Fenestration and door U-factor and product ratingsSYED RIZVIenergy_progress
05/12/2025Permanent certificateSYED RIZVIenergy_progress
05/12/2025Maintenance informationSYED RIZVIenergy_progress
04/08/2025HVAC-R and service water piping design and insulationSYED RIZVIenergy_progress
04/08/2025HVAC-R and service water heating equipmentSYED RIZVIenergy_progress
04/08/2025HVAC-R and service water heating system controlsSYED RIZVIenergy_progress
04/07/2025Energy Code Compliance InspectionsSYED RIZVIprogress
Latest 25 of 38.
▾Documents — 66 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch5
08/20/2026Q01204044-P2Request digital key ↗
08/20/2026Q01204044-P1Request digital key ↗
08/20/2026Q01204044-S2Request digital key ↗
Showing 3 of 5 on file for this type
▸Applications & Permits7
▸BISPLAN / WORK APPROVAL APPLICATION6
09/21/2016420944410Open ↗
11/27/2015420944410Open ↗
10/28/2015420944410Open ↗
Showing 3 of 6 on file for this type
▸BISWORK PERMIT APPLICATION1
07/13/2016420944410Open ↗
▸Zoning, Tax Lot & Property Records8
▸BISZONING DIAGRAM3
09/12/2016420944410Open ↗
09/12/2016420944410Open ↗
01/04/2016420944410Open ↗
▸DOB NOWZoning Exhibit form (1-5)2
08/15/2026Q01204044-P1Open ↗
08/13/2026Q01204044-I1Open ↗
▸DOB NOWZD1: DOB Zoning Diagram2
08/15/2026Q01204044-P1Open ↗
08/13/2026Q01204044-I1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026Q01204044-I1Open ↗
▸Seals & Professional Certifications20
▸DOB NOWProgress Inspector Seal & Signature10
08/29/2026Q01204044-P1Open ↗
08/29/2026Q01204044-P1Open ↗
08/29/2026Q01204044-P1Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/20/2026Q01204044-P2Open ↗
08/20/2026Q01204044-P1Open ↗
08/20/2026Q01204044-S2Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
08/29/2026Q01204044-P1Open ↗
08/29/2026Q01204044-P1Open ↗
08/23/2026Q01204044-I1Open ↗
Showing 3 of 4 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
02/11/2014420944410Open ↗
▸Trade Schedules & Equipment1
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE1
02/11/2014420944410Open ↗
▸Safety & Tenant Protection1
▸BISSTREET TREE CHECKLIST1
02/11/2014420944410Open ↗
▸Environmental & Asbestos6
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/20/2026Q01204044-S2Open ↗
08/20/2026Q01204044-S1Open ↗
08/20/2026Q01204044-I1Open ↗
Showing 3 of 5 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
02/11/2014420944410Open ↗
▸Energy Compliance1
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
02/11/2014420944410Open ↗
▸Approvals, Objections & Sign-offs4
▸BISSCHEDULE A - OCCUPANCY / USE3
11/27/2015420944410Open ↗
10/28/2015420944410Open ↗
02/11/2014420944410Open ↗
▸BISADMINISTRATIVE OBJECTIONS1
02/11/2014420944410Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
09/01/2016420944410Open ↗
02/11/2014420944410Open ↗
▸Filing & Intake Forms2
▸BISEFILING COVER SHEET1
02/11/2014420944410Open ↗
▸BISADDITIONAL INFORMATION1
10/28/2015420944410Open ↗
▸Other Documents9
▸DOB NOWSite Survey: Initial2
08/15/2026Q01204044-P1Open ↗
08/13/2026Q01204044-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone2
08/15/2026Q01204044-P1Open ↗
08/13/2026Q01204044-I1Open ↗
▸DOB NOWPlot Diagram2
08/15/2026Q01204044-P1Open ↗
08/13/2026Q01204044-I1Open ↗
▸DOB NOWProperty Ownership Certification2
08/20/2026Q01204044-I1Open ↗
08/15/2026Q01204044-P1Open ↗
▸BISPLOT DIAGRAM1
02/11/2014420944410Open ↗