← Back
One story retail building
43-15 BEACH 44 STREET
QUEENS · BIN 4301817
💬 Discuss this project
1965Year Built
1Stories
K1Building Class
R4Zoning
4,420 sfGross Floor Area
4Units
0 Open ViolationsFDNY Report ↗
One story retail building · Owner of record: 43 RD ST HOLDING CORP · 9,135 sf lot · 0.48 FAR built · Flood zone AE
Locations of Work
ArchitectureMechanicalPlumbing
Permit Issued — active, not yet Signed-off
RoofUnder Construction2p · 1 filing · 18 docs
Floor 1Under Construction6p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
KHALILCO1308/12/2026
TARIK HOLDING CORP103/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
KING ARCHITECT, PLLC407/29/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SEASONED HOME IMPROVEMEN*General Contractor204/09/2026
STOVALL, DARRYLElectrical203/21/2026
SIGNORE & SONS PLBG CORPPlumbing207/08/2026
MCQUEEN EUSEBIOElectrical103/21/2026
M&L SIGNS INCElectrical103/21/2026
EUSEBIO MCQUEENElectrical103/21/2026
LG ELITE PLUMBING INCPlumbing108/12/2026
RICHARD HIRSCHELElectrical103/21/2026
EVANS, DWAYNEElectrical103/21/2026
HERNANDEZ, LElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
A TECH ENGINEERING NYC, P6738204/23/2025
Building Lifecycle
All (25)Filed (4)Permit Issued (5)Violation (4)Inspection (1)Special Inspection (11)
08/11/2026
Permit issued — Plumbing
Q01179640-I1-PL
07/31/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
King Leung
07/29/2026
Filed — Alteration
HEREBY FILING PLUMBING WORK AT EXISTING FIRST FLOOR COMMERCIAL SPACE AS PER PLANS.
Q01179640-P1
07/13/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
King Leung
06/01/2026
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
08/12/2025
Violation issued (FDNY_NOV, closed)
07/10/2025
Permit issued — Plumbing
Q01179640-I1-PL
05/30/2025
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/06/2025
Permit issued — Mechanical Systems
Q01179582-S1-MS
04/23/2025
Filed — Alteration
HEREBY FILING RELATED MECHANICAL SYSTEM VENTILATION WORK AT 1ST FLOOR TENANT SPACE.
Q01179582-S1
04/14/2025
Permit issued — Plumbing
Q01179640-I1-PL
04/11/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
King Leung
04/11/2025
Special inspection requirement — Mechanical Systems
anthony santoro
04/11/2025
Special inspection requirement — Final
King Leung
04/11/2025
Special inspection requirement — HVAC-R and service water heating system controls
King Leung
04/10/2025
Permit issued — General Construction
Q01179582-I1-GC
03/13/2025
Filed — Alteration
HEREBY FILING PLUMBING WORK AT EXISTING FIRST FLOOR COMMERCIAL SPACE AS PER PLANS.
Q01179640-I1
03/13/2025
Filed — Alteration
HEREBY FILING RELATED MECHANICAL SYSTEM VENTILATION WORK AT 1ST FLOOR TENANT SPACE.
Q01179582-I1
02/11/2025
Special inspection requirement — Interior lighting power
King Leung
02/11/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
anthony santoro
02/11/2025
Special inspection requirement — Final
King Leung
02/11/2025
Special inspection requirement — Energy Code Compliance Inspections
King Leung
02/11/2025
Special inspection requirement — Fire-Resistance Rated Construction
King Leung
02/14/2023
Violation issued (FDNY_NOV, closed)
07/03/2007
Violation issued (FDNY_NOV, closed)
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedLG ELITE PLUMBING INC08/11/2026
DOB NOWPlumbingPermit IssuedSIGNORE & SONS PLBG CORP07/10/2025
DOB NOWMechanical SystemsPermit IssuedSEASONED HOME IMPROVEMEN*05/06/2025
DOB NOWPlumbingPermit IssuedSIGNORE & SONS PLBG CORP04/14/2025
DOB NOWGeneral ConstructionPermit IssuedSEASONED HOME IMPROVEMEN*04/10/2025
BISFPISSUEDFIRE COMMAND CO, INC03/30/2016
BISPLISSUEDMAGOR PLG AND HEATING01/17/1996
BISFPISSUEDMASTER FIRE PREVENTION SYSTEMS11/20/1995
BISOTISSUEDWKL CONST. INC.11/15/1995
1 project · most recent 04/23/2025
Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
04/23/2025Permit IssuedSEASONED HOME IMPROVEMEN*Ventilation Systems
Ventilation
Pennbarry FX138HFT 640 CFM · Kitchen Exhaust ×4
1 project · most recent 07/29/2026
Gas Water/Sanitary
FiledStatusContractorScope
07/29/2026Permit IssuedLG ELITE PLUMBING INCGas, Water/Sanitary
▾Field Inspections (DOB CAP) — 1
DateTypeResultReport
06/01/2026Fail-Final PL - Up to 3 Requested FloorsFailView ↗
▾Special Inspection Requirements (DOB NOW) — 11
DateRequirementInspectorRole
07/31/2026HVAC-R and service water piping design and insulationKing Leungenergy_progress
07/13/2026HVAC-R and service water piping design and insulationKing Leungenergy_progress
04/11/2025HVAC-R and service water piping design and insulationKing Leungenergy_progress
04/11/2025Mechanical Systemsanthony santorospecial
04/11/2025FinalKing Leungprogress
04/11/2025HVAC-R and service water heating system controlsKing Leungenergy_progress
02/11/2025Interior lighting powerKing Leungenergy_progress
02/11/2025Fire-Resistant Penetrations and Jointsanthony santorospecial
02/11/2025FinalKing Leungprogress
02/11/2025Energy Code Compliance InspectionsKing Leungprogress
02/11/2025Fire-Resistance Rated ConstructionKing Leungprogress
▾Documents — 37 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch5
08/20/2026Q01179640-P1Request digital key ↗
08/20/2026Q01179640-I1Request digital key ↗
08/20/2026Q01179582-I1Request digital key ↗
Showing 3 of 5 on file for this type
▸Applications & Permits2
▸BISPLAN / WORK APPROVAL APPLICATION1
03/17/2016440296378Open ↗
▸BISWORK PERMIT APPLICATION1
03/30/2016440296378Open ↗
▸Seals & Professional Certifications16
▸DOB NOWProgress Inspector Seal & Signature6
09/02/2026Q01179582-I1Open ↗
09/02/2026Q01179582-I1Open ↗
08/28/2026Q01179640-P1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/20/2026Q01179640-P1Open ↗
08/20/2026Q01179582-P1Open ↗
08/20/2026Q01179582-S1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature2
09/02/2026Q01179582-I1Open ↗
08/25/2026Q01179582-S1Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
03/17/2016440296378Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
03/17/2016440296378Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
03/17/2016440296378Open ↗
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/20/2026Q01179640-P1Open ↗
08/20/2026Q01179582-P1Open ↗
08/20/2026Q01179582-S1Open ↗
Showing 3 of 5 on file for this type
▸Inspections & Test Reports1
▸BISTECHNICAL REPORT: RESPONSIBILITY1
03/17/2016440296378Open ↗
▸Approvals, Objections & Sign-offs1
▸BISLETTERS - SUPPORTING DOCUMENTATION1
03/17/2016440296378Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
03/17/2016440296378Open ↗
▸Filing & Intake Forms6
▸DOB NOWAI1 Form5
08/20/2026Q01179640-P1Open ↗
08/20/2026Q01179582-P1Open ↗
08/13/2026Q01179582-S1Open ↗
Showing 3 of 5 on file for this type
▸BISEFILING JOB APPLICATION COVER SHEET1
03/17/2016440296378Open ↗