← Back
Multi-story retail building (2+)
89-43 ELMHURST AVENUE
QUEENS · BIN 4311578
💬 Discuss this project
1987Year Built
2Stories
K2Building Class
R6Zoning
2,010 sfGross Floor Area
3Units
4 Open Violations 2 unresolved · 2 paperwork only ▸FDNY Report ↗
Multi-story retail building (2+) · Owner of record: J & B 89 INC. · 798 sf lot · 2.52 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbing
Permit Issued — active, not yet Signed-off
Floor 1Under Construction5p · 2 filings · 9 docs
CellarUnder Construction4p · 2 filings · 9 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
J & B 89 INC J&B 89 INC503/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
01/23/2017$1.1M—Private party → J & B 89 INC.$562/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
CLIP ARCHITECTS207/21/2026
ISEED CONSTRUCTION INC102/09/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
GOLDEN CONSTRUCTION NY COGeneral Contractor108/30/2026
THOMAS F. CASH & SONS INCPlumbing107/08/2026
TRI STATE PLBG & HTG INCPlumbing109/26/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NKM ENGINEERING PLLC6244107/21/2026
ISEED CONSTRUCTION INC8336102/09/2026
Building Lifecycle
All (30)Filed (3)Permit Issued (3)Violation (11)Inspection (1)Objection (2)Special Inspection (10)
09/25/2026
Permit issued — Plumbing
Q01429630-S1-PL
08/28/2026
Permit issued — Mechanical Systems
Q01429630-I1-GC-CX
08/04/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
08/03/2026
Objection resolved — Addressed
07/28/2026
Objection raised — Other
07/21/2026
Filed — Alteration
TENANT BUILD OUT FOR A TAKE-OUT RESTAURANT AS PER THE PLANS FILED HEREWITH. NO CHANGE TO THE USE, EGRESS OR OCCUPANCY.
Q01429630-S1
07/21/2026
Filed — Alteration
TENANT BUILD OUT FOR A TAKE-OUT RESTAURANT AS PER THE PLANS FILED HEREWITH. NO CHANGE TO THE USE, EGRESS OR OCCUPANCY.
Q01429630-I1
07/21/2026
Special inspection requirement — Shutoff dampers
07/21/2026
Special inspection requirement — Lighting controls
07/21/2026
Special inspection requirement — Energy Code Compliance Inspections
07/21/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
07/21/2026
Special inspection requirement — Fire-Resistance Rated Construction
07/21/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
07/21/2026
Special inspection requirement — HVAC-R and service water heating equipment
07/21/2026
Special inspection requirement — Interior lighting power
07/11/2026
Special inspection requirement — Mechanical Systems
07/11/2026
Special inspection requirement — Final
06/18/2026
Permit issued — Plumbing
Q01357142-I1-PL
02/09/2026
Filed — Alteration
Q01357142-I1
12/29/2025
Violation issued (ECB, open)
Plumbing
12/29/2025
Violation issued (ECB, open)
Plumbing
12/26/2025
Violation issued (ECB, open)
Construction
12/26/2025
Violation issued (ECB, open)
Construction
06/06/2023
Violation issued (ECB, closed)
Boilers
02/03/2009
Violation issued (ECB, closed)
Construction
07/30/2008
Violation issued (ECB, closed)
Construction
02/27/2001
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
08/29/1995
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/07/1994
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/28/1993
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedTRI STATE PLBG & HTG INC09/25/2026
DOB NOWMechanical SystemsPermit IssuedGOLDEN CONSTRUCTION NY CO08/28/2026
DOB NOWPlumbingPermit IssuedTHOMAS F. CASH & SONS INC06/18/2026
BISPLISSUEDMIKE CATSIMALIS PLBG&HTG05/25/1990
1 project · most recent 07/21/2026
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
07/21/2026Permit IssuedGOLDEN CONSTRUCTION NY COHeating and Air Conditioning Systems
Heat / Cool
Daikin FTXV15AVJU9 15,000 BTU · Fan Coil Indoor ×2
3MXM24AVJU9 47,000 BTU · Condensing Unit ×1
1 project · most recent 07/21/2026
Gas Water/Sanitary
FiledStatusContractorScope
07/21/2026Permit IssuedTRI STATE PLBG & HTG INCGas, Water/Sanitary
1 project · most recent 09/25/2026
General Wiring
FiledStatusContractorScope
09/25/2026Permit IssuedNY FOREVER ELECTRIC LLCGeneral Wiring
▾Field Inspections (DOB CAP) — 1
DateTypeResultReport
08/04/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 10
DateRequirementInspectorRole
07/21/2026Shutoff dampers—energy_progress
07/21/2026Lighting controls—energy_progress
07/21/2026Energy Code Compliance Inspections—progress
07/21/2026Fire-Resistant Penetrations and Joints—special
07/21/2026Fire-Resistance Rated Construction—progress
07/21/2026HVAC-R and service water piping design and insulation—energy_progress
07/21/2026HVAC-R and service water heating equipment—energy_progress
07/21/2026Interior lighting power—energy_progress
07/11/2026Mechanical Systems—special
07/11/2026Final—progress
▾Documents — 9 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/17/2026Q01357142-I1Request digital key ↗
08/16/2026Q01429630-S1Request digital key ↗
08/15/2026Q01429630-I1Request digital key ↗
▸Seals & Professional Certifications3
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/17/2026Q01357142-I1Open ↗
08/16/2026Q01429630-I1Open ↗
08/16/2026Q01429630-S1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/17/2026Q01357142-I1Open ↗
08/16/2026Q01429630-S1Open ↗
08/15/2026Q01429630-I1Open ↗