← Back
One story retail building
34-57 JUNCTION BOULEVARD
QUEENS · BIN 4314524
💬 Discuss this project
1988Year Built
1Stories
K1Building Class
R6AZoning
1,580 sfGross Floor Area
2Units
0 Open ViolationsFDNY Report ↗
One story retail building · 973 sf lot · 1.62 FAR built · Flood zone X
Locations of Work
ArchitectureMechanical
Roof1p · 1 filing · 13 docs
Floor 11p · 1 filing · 13 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
SHANIEL LLC203/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
KENNY LEE ARCHITECT210/01/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
KORMAN DESIGN & BUILD403/21/2026
Building Lifecycle
All (31)Filed (2)Violation (3)Objection (14)Special Inspection (12)
10/29/2025
Objection resolved — Addressed
10/29/2025
Objection resolved — Addressed
10/23/2025
Objection raised — Scope
10/23/2025
Objection raised — Scope
10/17/2025
Objection resolved — Addressed
10/16/2025
Objection resolved — Addressed
10/16/2025
Objection resolved — Addressed
10/16/2025
Objection resolved — Addressed
10/16/2025
Objection resolved — Addressed
10/14/2025
Objection raised — Plumbing
10/10/2025
Objection raised — Plumbing
10/10/2025
Objection raised — Energy
10/10/2025
Objection raised — Scope
10/10/2025
Objection raised — Scope
10/01/2025
Filed — Alteration
INSTALLATION OF PLUMBING FIXTURES AND ELEC. HW HEATER
Q01290061-S1
10/01/2025
Filed — Alteration
INSTALLATION OF PLUMBING FIXTURES AND ELEC. HW HEATER
Q01290061-I1
09/24/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
09/24/2025
Special inspection requirement — Energy Code Compliance Inspections
09/24/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
09/24/2025
Special inspection requirement — HVAC-R and service water heating system controls
09/24/2025
Special inspection requirement — HVAC-R and service water heating equipment
09/23/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
09/23/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
09/23/2025
Special inspection requirement — HVAC-R and service water heating system controls
09/23/2025
Special inspection requirement — HVAC-R and service water heating equipment
09/23/2025
Special inspection requirement — Energy Code Compliance Inspections
09/18/2025
Special inspection requirement — Final
09/18/2025
Special inspection requirement — Mechanical Systems
05/03/2022
Violation issued (ECB, closed)
Construction
05/03/2022
Violation issued (ECB, closed)
Zoning
05/20/2013
Violation issued (ECB, closed)
Unknown
Nothing on file for this building.
1 project · most recent 10/01/2025
Refrigeration Systems
FiledStatusContractorScopeMake / Model / Capacity
10/01/2025——Refrigeration Systems
Refrigeration
Tecumseh ASHS9516ZNAFP1 16,000 BTU · Refrigeration Unit ×1
1 project · most recent 10/01/2025
Water/Sanitary
FiledStatusContractorScope
10/01/2025——Water/Sanitary
▾Special Inspection Requirements (DOB NOW) — 12
DateRequirementInspectorRole
09/24/2025Fire-Resistant Penetrations and Joints—special
09/24/2025Energy Code Compliance Inspections—progress
09/24/2025HVAC-R and service water piping design and insulation—energy_progress
09/24/2025HVAC-R and service water heating system controls—energy_progress
09/24/2025HVAC-R and service water heating equipment—energy_progress
09/23/2025HVAC-R and service water piping design and insulation—energy_progress
09/23/2025Fire-Resistant Penetrations and Joints—special
09/23/2025HVAC-R and service water heating system controls—energy_progress
09/23/2025HVAC-R and service water heating equipment—energy_progress
09/23/2025Energy Code Compliance Inspections—progress
09/18/2025Final—progress
09/18/2025Mechanical Systems—special
▾Documents — 13 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/18/2026Q01290061-S1Request digital key ↗
08/18/2026Q01290061-I1Request digital key ↗
▸Seals & Professional Certifications9
▸DOB NOWProgress Inspector Seal & Signature5
09/01/2026Q01290061-S1Open ↗
09/01/2026Q01290061-S1Open ↗
09/01/2026Q01290061-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/18/2026Q01290061-S1Open ↗
08/18/2026Q01290061-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
09/01/2026Q01290061-S1Open ↗
09/01/2026Q01290061-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/18/2026Q01290061-I1Open ↗
08/18/2026Q01290061-S1Open ↗