← Back
Primarily 4 family with 1 store or office
25-03 23 STREET
QUEENS · BIN 4431118
💬 Discuss this project
2014Year Built
4.5Stories
S4Building Class
R6BZoning
5,353 sfGross Floor Area
5Units
Rent Stabilized1 Open Violation ▸FDNY Report ↗
Primarily 4 family with 1 store or office · Owner of record: 25-03 23RD STREET CORPORATION · 2,650 sf lot · 2.02 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Permit Issued — active, not yet Signed-off
Floor 1Under Construction3p · 1 filing · 10 docs
1 job · most recent 11/08/2023
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
11/08/2023Permit IssuedMULTILINE CONTR GROUP INCHeating and Air Conditioning Systems
Heat / Cool
Fujitsu AOU48RLAVM 48,000 BTU · Condensing Unit ×1
1 job · most recent 11/08/2023
Gas Water/Sanitary
FiledStatusContractorScope
11/08/2023Permit IssuedKISHAN PLUMBING INCGas, Water/Sanitary
Building Lifecycle
All (23)Filed (3)Permit Issued (3)Violation (6)Inspection (7)Special Inspection (4)
02/05/2026
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
02/05/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
12/15/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
11/20/2025
Permit issued — Plumbing
Q00870257-S1-PL
10/27/2025
Inspection — Pass-Final SP - Up to 3 Requested Floors
Pass
View inspection ↗
02/11/2025
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
02/11/2025
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
02/11/2025
Inspection — Certified Sprinkler - SP - Roughing
Certified
View inspection ↗
08/21/2024
Permit issued — General Construction
Q00870257-I1-GC
11/15/2023
Permit issued — Plumbing
Q00870257-S1-PL
11/08/2023
Filed — Alteration
MECHANICAL WORK-TYPE INSTALLATION OF KITCHEN FIRE-SUPPRESSION SYSTEM AND MINI-SPLIT UNIT AND TO SUPERSEDE APPLICATION#'S: 410077508 & 42029159.
Q00870257-S2
10/25/2023
Filed — Alteration
MECHANICAL WORK-TYPE INSTALLATION OF KITCHEN FIRE-SUPPRESSION SYSTEM AND MINI-SPLIT UNIT AND TO SUPERSEDE APPLICATION#'S: 410077508 & 42029159.
Q00870257-S1
10/19/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
10/19/2023
Special inspection requirement — Mechanical Systems
10/19/2023
Special inspection requirement — Final
10/19/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Akeeb Shekoni
09/25/2023
Filed — Alteration
MECHANICAL WORK-TYPE INSTALLATION OF KITCHEN FIRE-SUPPRESSION SYSTEM AND MINI-SPLIT UNIT AND TO SUPERSEDE APPLICATION#'S: 410077508 & 42029159.
Q00870257-I1
09/30/2011
Violation issued (FDNY_ORDER, closed)
08/02/2011
Violation issued (FDNY_ORDER, closed)
06/09/2010
Violation issued (ECB, closed)
Unknown
05/27/2010
Violation issued (ECB, closed)
Construction
05/24/2010
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/30/2008
Violation issued (ECB, closed)
Construction
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
25-03 23RD STREET1007/08/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
HANSA BUILDING ENGINEERING SERVICES311/08/2023
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
KISHAN PLUMBING INCPlumbing207/08/2026
MULTILINE CONTR GROUP INCGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ASKON ARCHITECT, P.C.3596210/25/2023
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedN AND S PLUMBING INC11/20/2025
DOB NOWGeneral ConstructionPermit IssuedMULTILINE CONTR GROUP INC08/21/2024
DOB NOWPlumbingPermit IssuedN AND S PLUMBING INC11/15/2023
BISEQISSUEDSTEEL SYSTEMS LLC04/21/2015
BISMHISSUEDA INTERNATIONAL LTD02/15/2011
BISOTISSUEDA INTERNATIONAL LTD02/09/2011
▾Field Inspections (DOB CAP) — 7
DateTypeResultReport
02/05/2026Certified Gas-Gas-Piping-RoughingCertifiedView ↗
02/05/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
12/15/2025Pass-Final CND-Occupancy InspectionPassView ↗
10/27/2025Pass-Final SP - Up to 3 Requested FloorsPassView ↗
02/11/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
02/11/2025Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
02/11/2025Certified Sprinkler - SP - RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 4
DateRequirementInspectorRole
10/19/2023Fire-Resistant Penetrations and Joints—special
10/19/2023Mechanical Systems—special
10/19/2023Final—progress
10/19/2023Fire-Resistant Penetrations and JointsAkeeb Shekonispecial
▾Documents — 47 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/23/2026Q00870257-S2Request digital key ↗
08/23/2026Q00870257-I1Request digital key ↗
08/23/2026Q00870257-S1Request digital key ↗
▸Applications & Permits10
▸BISPLAN / WORK APPROVAL APPLICATION6
04/17/2015440213369Open ↗
05/16/2011420291598Open ↗
04/26/2011420291598Open ↗
Showing 3 of 6 on file for this type
▸BISWORK PERMIT APPLICATION4
04/17/2015440213369Open ↗
02/16/2011420291598Open ↗
02/09/2011420291598Open ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications14
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION5
10/31/2016440213369Open ↗
10/31/2016440213369Open ↗
12/08/2010420291598Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/23/2026Q00870257-S2Open ↗
08/23/2026Q00870257-I1Open ↗
08/23/2026Q00870257-S1Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
04/17/2015440213369Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
04/17/2015440213369Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
04/17/2015440213369Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM1
03/18/2008410077508Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
03/18/2008410077508Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
09/22/2026Q00870257-S1Open ↗
▸Trade Schedules & Equipment2
▸BISSCHEDULE B - PLUMBING2
04/04/2011420291598Open ↗
12/08/2010420291598Open ↗
▸Safety & Tenant Protection1
▸BISSTREET TREE CHECKLIST1
12/08/2010420291598Open ↗
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/23/2026Q00870257-S2Open ↗
08/23/2026Q00870257-S1Open ↗
08/23/2026Q00870257-I1Open ↗
▸BISTHIS IS NOT AN ASBESTOS PROJECT2
01/28/2011420291598Open ↗
03/18/2008410077508Open ↗
▸Energy Compliance1
▸BISELECTRICAL APPLICATION FOR SIDEWALK SHED LIGHTING1
04/17/2015440213369Open ↗
▸Inspections & Test Reports1
▸BISTECHNICAL REPORT: RESPONSIBILITY1
04/17/2015440213369Open ↗
▸Approvals, Objections & Sign-offs4
▸BISADMINISTRATIVE OBJECTIONS3
12/08/2010420291598Open ↗
03/18/2008410077508Open ↗
03/18/2008410077508Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
10/31/2016440213369Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
12/08/2010420291598Open ↗
04/30/2008410077508Open ↗
▸Filing & Intake Forms4
▸BISEFILING COVER SHEET3
01/28/2011420291598Open ↗
12/08/2010420291598Open ↗
03/18/2008410077508Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
04/17/2015440213369Open ↗