← Back
Condo, residential unit in 1-3 story building
Baisley Park Plaza Condominium
137-12 167 STREET · BIN 4431796
💬 Discuss this project
1988Year Built
2Stories
R3Building Class
R3-1Zoning
16,180 sfGross Floor Area
20Units
Rent Stabilized4 Open Violations ▸FDNY Report ↗
Condo, residential unit in 1-3 story building · Owner of record: BAISLEY PARK PLAZA CONDO · 37,857 sf lot · 0.43 FAR built · Flood zone X
Locations of Work
Structural
Floor 13p · 1 filing · 10 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
5D ARCHITECTURE & ENGINEERING PLLC.206/12/2023
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
D&S GEMINI DESIGN FLOORI*General Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
5D ARCH. & ENG., PLLC2781206/12/2023
Building Lifecycle
All (13)Filed (2)Permit Issued (1)Inspection (2)Special Inspection (8)
09/05/2023
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
06/30/2023
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
06/13/2023
Special inspection requirement — Wood – Seismic Resistance
06/13/2023
Special inspection requirement — Construction Operations Influencing Adjacent Structures
JACKMAN PRESCOD
06/13/2023
Special inspection requirement — Structural Stability – Alterations of existing buildings
JACKMAN PRESCOD
06/13/2023
Special inspection requirement — Final
JACKMAN PRESCOD
06/12/2023
Filed — Alteration
INSTALL TEMPORARY STRUCTURAL WOOD SHORING AND BRACING. REMOVE FIRE DAMAGED 2"x8" WOOD BEAM AND INSTALL NEW (3) 1-3/4" x 9-1/4" LVL STRUCTURAL BEAM.
Q00820751-P1
06/12/2023
Special inspection requirement — Construction Operations Influencing Adjacent Structures
JACKMAN PRESCOD
06/12/2023
Special inspection requirement — Structural Stability – Alterations of existing buildings
JACKMAN PRESCOD
06/12/2023
Special inspection requirement — Wood – Seismic Resistance
06/12/2023
Special inspection requirement — Final
JACKMAN PRESCOD
03/28/2023
Permit issued — Structural
Q00820751-I1-GC
01/30/2023
Filed — Alteration
INSTALL TEMPORARY STRUCTURAL WOOD SHORING AND BRACING. REMOVE FIRE DAMAGED 2"x8" WOOD BEAM AND INSTALL NEW (3) 1-3/4" x 9-1/4" LVL STRUCTURAL BEAM.
Q00820751-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralPermit IssuedD&S GEMINI DESIGN FLOORI*03/28/2023
1 project · most recent 09/23/2022
General Wiring
FiledStatusContractorScope
09/23/2022Permit IssuedC & A ELECTRICAL CORPGeneral Wiring
1 project · most recent 06/12/2023
Wood
FiledStatusContractorScope
06/12/2023Permit IssuedD&S GEMINI DESIGN FLOORI*Wood
▾Field Inspections (DOB CAP) — 2
DateTypeResultReport
09/05/2023Fail-Final General Construction Non-Directive 14FailView ↗
06/30/2023Fail-Final General Construction Non-Directive 14FailView ↗
▾Special Inspection Requirements (DOB NOW) — 8
DateRequirementInspectorRole
06/13/2023Wood – Seismic Resistance—special
06/13/2023Construction Operations Influencing Adjacent StructuresJACKMAN PRESCODspecial
06/13/2023Structural Stability – Alterations of existing buildingsJACKMAN PRESCODspecial
06/13/2023FinalJACKMAN PRESCODprogress
06/12/2023Construction Operations Influencing Adjacent StructuresJACKMAN PRESCODspecial
06/12/2023Structural Stability – Alterations of existing buildingsJACKMAN PRESCODspecial
06/12/2023Wood – Seismic Resistance—special
06/12/2023FinalJACKMAN PRESCODprogress
▾Documents — 10 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/24/2026Q00820751-I1Request digital key ↗
08/24/2026Q00820751-P1Request digital key ↗
▸Seals & Professional Certifications8
▸DOB NOWSpecial Inspector Seal & Signature4
08/28/2026Q00820751-P1Open ↗
08/28/2026Q00820751-P1Open ↗
08/24/2026Q00820751-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/24/2026Q00820751-P1Open ↗
08/24/2026Q00820751-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
08/28/2026Q00820751-P1Open ↗
08/24/2026Q00820751-I1Open ↗